CATEGORIES

A-Type RCBO EV Kit – 2 Way 6 A B Curve (WMEV206B)

  • £28.34
  • 18th Ed. Compliant

    2-Year Warranty

    UK Stock

    Free Delivery £30+

    Secure Payments With

    Google Pay PayPal

    The WMEV206B is a 2-way A-Type RCBO EV Kit fitted with a 6 A B-curve high-immunity Type A RCBO. Designed specifically for EV charger supplies, it delivers overload, short-circuit and earth-leakage protection in line with 18th Edition Amendment 2 requirements (30 mA AC + 6 mA DC detection). This compact...

    The WMEV206B is a 2-way A-Type RCBO EV Kit fitted with a 6 A B-curve high-immunity Type A RCBO. Designed specifically for EV charger supplies, it delivers overload, short-circuit and earth-leakage protection in line with 18th Edition Amendment 2 requirements (30 mA AC + 6 mA DC detection).

    This compact enclosure provides switched live and neutral isolation with clear fault indication for AC or DC imbalance. It’s pre-assembled, regulation-ready, and ideal for dedicated EV circuits up to 6 A in domestic or light-commercial environments.

    Installer Tip: Choose a 6 A B-curve RCBO for low-power EV chargers or control circuits with minimal inrush current. For units above 3.6 kW or with transformer inputs, see our C-curve variants below.

    • Type A RCBO – 30 mA AC + 6 mA DC leakage detection
    • 6 A B-curve device for low-load EV applications
    • Switched neutral design – isolates both conductors
    • Compact 2-way steel enclosure with hinged cover
    • Complies with BS EN 61009-1 and BS 7671 (A2)
    • High-immunity design reduces nuisance tripping with EV chargers
    Part Code Rating Curve Typical Use
    WMEV206B 6 A B Low-load EV chargers / control circuits
    WMEV216B 16 A B Standard single-phase EV installations
    WMEV232C 32 A C 7 kW chargers with higher inrush current

    Each kit arrives pre-configured and ready to install, combining Type A RCBO protection with a durable steel enclosure. For PEN fault compliance and load balancing, pair with our PME Fault Detection Unit.

    Is this EV kit compliant with 18th Edition Amendment 2?

    Yes – it includes a Type A RCBO providing 30 mA AC + 6 mA DC detection, meeting current BS 7671 EV circuit requirements.

    When should I choose a 6 A B Curve variant?

    Use this variant for low-power EV chargers or control circuits drawing under 6 A. For 7 kW or inrush-heavy units, select a C-curve model.

    Does this RCBO isolate both live and neutral?

    Yes – the switched neutral design ensures both conductors are disconnected during a fault or manual isolation.

    Can I add surge protection to this kit?

    Yes – pair with our Single Module SPD or install an upstream surge unit as required.

    Can this kit be used for solar or PV as well as EV?

    Yes – the Type A RCBO is bi-directional and suitable for both EV and PV circuits. For larger systems, see our 5-Module Solar Board with SPD.

    • Part Code: WMEV206B
    • Enclosure: 2-way compact steel with hinged lid
    • Device: Type A RCBO, high immunity
    • Rated Current (In): 6 A
    • Curve: B
    • Earth Leakage: 30 mA AC + 6 mA DC
    • Breaking Capacity: 6 kA
    • Poles: 1P + N (switched neutral)
    • Standards: BS EN 61009-1; BS 7671:2018 (A2)
    • Typical Use: Low-load EV chargers or pilot supply circuits

    The WMEV206B kit is supplied pre-assembled for fast fit-out. Installation and testing must be carried out by a qualified electrician.

    • Mount enclosure in a dry or sheltered location (IP rated if outdoors)
    • Select 6 A B-curve for low-power EV chargers or pilot control circuits
    • Ensure all connections comply with BS 7671 (A2)
    • Add surge protection upstream if required by site specification