A-Type RCBO EV Kit – 2 Way 16 A B Curve (WMEV216B)
18th Ed. Compliant
2-Year Warranty
UK Stock
Free Delivery £30+
Secure Payments With
The WMEV216B is a 2-way A-Type RCBO EV Kit fitted with a 16 A B-curve high-immunity Type A RCBO. It provides overload, short-circuit and earth-leakage protection for EV charger circuits, detecting 30 mA AC + 6 mA DC fault currents to meet 18th Edition Amendment 2 requirements. This variant is...
The WMEV216B is a 2-way A-Type RCBO EV Kit fitted with a 16 A B-curve high-immunity Type A RCBO. It provides overload, short-circuit and earth-leakage protection for EV charger circuits, detecting 30 mA AC + 6 mA DC fault currents to meet 18th Edition Amendment 2 requirements.
This variant is ideal for standard domestic single-phase EV chargers (up to 3.6 kW) where supply diversity and nuisance tripping must be minimised. It offers full dual-pole isolation and clear fault indication in a compact 2-way steel enclosure ready for fast fit-out and inspection.
Installer Tip: 16 A B-curve is the go-to choice for most 3.6 kW chargers. If your charger has a transformer or higher inrush current, switch to a C-curve version for extra surge tolerance.
- 16 A B-curve Type A RCBO (30 mA AC + 6 mA DC detection)
- Dual-pole (1P + N) isolation – disconnects live and neutral
- Pre-assembled in a compact 2-way steel enclosure
- Complies with BS EN 61009-1 and BS 7671 (A2)
- High-immunity design prevents false trips from EV charging loads
| Part Code | Rating | Curve | Typical Use |
|---|---|---|---|
| WMEV210B | 10 A | B | Small EV chargers / load-limited circuits |
| WMEV216B | 16 A | B | Standard 3.6 kW single-phase EV chargers |
| WMEV220B | 20 A | B | Heavier domestic or light commercial chargers |
Each kit arrives ready to install with a factory-fitted Type A RCBO and steel enclosure. For PEN fault compliance and load balancing, pair with our PME Fault Detection Unit. Add a Single Module SPD for surge defence where specified.
Is this kit compliant for EV charger circuits?
Yes – it includes a Type A RCBO with 30 mA AC + 6 mA DC detection as required by 18th Edition Amendment 2.
When should I use a 16 A B Curve model?
This is the recommended rating for most 3.6 kW chargers. For 7 kW chargers or units with transformers, choose a C-curve variant.
Does it isolate both live and neutral?
Yes – the 1P + N RCBO switches both conductors for full isolation and safety.
Can I add surge protection?
Yes – fit a Single Module SPD or upstream surge unit if required by site spec.
Is it suitable for PV as well as EV circuits?
Yes – the bi-directional Type A RCBO is safe for both EV and solar PV applications.
- Part Code: WMEV216B
- Enclosure: 2-way steel with hinged lid
- Device: Type A RCBO (high immunity)
- Rated Current (In): 16 A
- Curve: B
- Earth Leakage: 30 mA AC + 6 mA DC
- Breaking Capacity: 6 kA
- Poles: 1P + N (switched neutral)
- Standards: BS EN 61009-1; BS 7671:2018 (A2)
- Typical Use: Standard 3.6 kW EV charging circuits
The WMEV216B kit is delivered pre-wired for speed on site. All final testing must be performed by a qualified electrician.
- Mount in a dry or IP-rated location if outdoors
- Select 16 A B-curve for standard 3.6 kW chargers
- Verify Zs and disconnection times to BS 7671 A2
- Add upstream SPD if required by site specification