High Current MCBs 63A–125A for Sub-Mains & Heavy-Load Circuits

High current MCBs from 63A to 125A are used where a circuit carries more load than a standard final circuit breaker is designed for. They are commonly specified for sub-mains, plant equipment, HVAC systems, distribution board feeds, and other installations where higher current capacity is needed.

This range is built for electricians and contractors working on heavier-duty circuits, with options covering different current ratings, pole formats, and trip characteristics depending on the load and supply arrangement.

Quick answer: A high current MCB is typically a breaker rated from 63A to 125A, used for larger loads, sub-main feeds, and distribution circuits where standard lower-rated MCBs are not suitable.

Compared with standard domestic MCB ratings, these devices are chosen where the installation design calls for a breaker that can handle a higher continuous current and protect larger cables, feeders, or more demanding equipment. That makes them a common choice on commercial boards, industrial systems, and larger specialist installations.

  • 63A–125A current range – for larger loads and feeder circuits
  • Single, 2 pole, 3 pole and 4 pole formats – to suit different supply arrangements
  • B and C curve options – depending on circuit behaviour and inrush current
  • Suitable for sub-mains and heavy-load circuits – including plant and building services
  • Used in commercial and industrial boards – where stronger-duty circuit protection is required

Need related protection products? Browse our full MCB range, 3 pole MCBs, 4 pole MCBs, and three phase boards & accessories. For delivery and returns, see our delivery information and returns policy.

Showing 1 to 11 of 11 items
✓ In stock SKU: WKC4100C

4 Pole MCB 10kA C Curve 100A WKC4100C

£26.25 ex VAT £31.50 inc VAT

The WCED WKC4100C is a 4 Pole 100A MCB with a C curve tripping characteristic and a 10kA breaking capacity. Designed for high-demand installations,...

✓ In stock SKU: WARB3100C

3 Pole 100A Auto Resetting MCBs WARB3100C

£68.30 ex VAT £81.96 inc VAT

The WCED WARB3100C is a 3 Pole 100A Auto Resetting MCB designed for advanced circuit protection where uptime is critical. Unlike a standard MCB,...

✓ In stock SKU: WKC280B

80A 2 Pole 10kA MCB – B Curve (WKC280B)

£9.08 ex VAT £10.90 inc VAT

The WKC280B is an 80A 2 Pole 10kA Miniature Circuit Breaker (MCB) designed to provide dependable overload and short-circuit protection for high-load single-phase circuits,...

✓ In stock SKU: WKC463C

63A 4 Pole 10kA MCB C Curve – WKC463C

£15.05 ex VAT £18.06 inc VAT

The WKC463C is a 63A 4 pole 10kA Miniature Circuit Breaker (MCB) engineered for three-phase + neutral protection. With its C Curve trip characteristic,...

✓ In stock SKU: WKC463B

63A 4 Pole 10kA MCB B Curve – WKC463B

£15.05 ex VAT £18.06 inc VAT

The WKC463B is a 63A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its B Curve trip characteristic,...

✓ In stock SKU: WKC163C

1 Pole 10kA MCB 63A C Curve WKC163C

£5.00 ex VAT £6.00 inc VAT

The WCED WKC Series 10kA Miniature Circuit Breakers (MCBs) are high-performance devices designed for precise overcurrent detection and short-circuit protection. Built to handle demanding...

✓ In stock SKU: WKC150B

1 Pole 10kA MCB 63A B Curve WKC163B

£5.00 ex VAT £6.00 inc VAT

The WCED WKC Series 10kA Miniature Circuit Breakers (MCBs) are high-performance devices designed for precise overcurrent detection and short-circuit protection. Built to handle demanding...

Specifying a High-Current MCB

MCBs rated from 63A upwards may be used on suitable feeders, submains and equipment circuits. Their use depends on the full design: continuous load, conductor capacity, fault level, trip curve, pole arrangement, terminals and coordination with upstream and downstream protection.

Single & 2-Pole Devices

Suitable for certain single-phase feeders and loads. Check the exact conductor switching arrangement and terminal capacity.

View 2-Pole MCBs →

3 & 4-Pole Devices

Used on suitable three-phase distribution or plant circuits. Neutral switching and pole protection must match the system design.

View 4-Pole MCBs →

10kA Breaking Capacity

Many high-current applications also have elevated fault levels, but breaking capacity must be verified independently from current rating.

View 10kA MCBs →

Specification Checklist

  • Continuous load: calculate design current and any duty-cycle effects
  • Conductor capacity: account for installation method, grouping and temperature
  • Terminal limits: confirm conductor size, lug arrangement and tightening requirements
  • Fault performance: verify breaking capacity and automatic disconnection
  • Protection coordination: assess discrimination and backup with other devices