3 Phase RCDs for Three-Phase + Neutral Circuit Protection
3 phase RCDs provide residual current protection across all three live phases and the neutral conductor. Designed for three-phase loads, sub-mains and distribution circuits, they deliver essential shock and fire protection on commercial and industrial installations.
Read more
These 4-pole RCDs disconnect L1, L2, L3 and N simultaneously during a fault, preventing dangerous imbalance or partial isolation. Available in 30mA, 100mA and 300mA sensitivities, they support both personal protection and fire-rated selective protection depending on the application.
- 4-pole (3P+N) protection for true three-phase circuits
- 30mA, 100mA & 300mA options for shock or fire protection
- Type A and Type B variants depending on load characteristics
- Suitable for motors, plant and multi-phase equipment
- 18th Edition compliant for new and upgraded installations
These devices are essential wherever three-phase equipment is installed and offer guaranteed, simultaneous disconnection for safe maintenance and reliable protection against earth leakage faults.
4 Pole Type A RCD – 63A High Immunity
£22.20
The WAR463-030 is a 4 pole, 63A Type A RCD with high immunity, engineered to reduce nuisance tripping on circuits affected by surge currents or harmonics. Fully compliant with BS EN 61008-1 and BS EN 61008-2-1, it provides reliable residual current protection for three-phase distribution...
4 Pole Type A RCD – 40A High Immunity
£22.20
The WAR440-030 is a 4 pole, 40A Type A RCD with high immunity, engineered to reduce nuisance tripping on circuits affected by surge currents or harmonics. Fully compliant with BS EN 61008-1 and BS EN 61008-2-1, it provides reliable residual current protection for three-phase distribution...
A Type Time Delay RCD – 80A 100mA, 4 Pole (WARTD480-100)
£38.75
The WARTD480-100 A-Type 100mA Time Delay RCD is a 4 Pole S-Type device rated at 80A, designed for selective upstream protection. Its built-in delay ensures only downstream RCDs disconnect under fault, maintaining continuity on unaffected circuits. Commonly used in three-phase distribution systems, EV charging installations,...
A Type Time Delay RCD – 63A 100mA, 4 Pole (WARTD463-100)
£30.25
The WARTD463-100 A-Type 100mA Time Delay RCD is a 4 Pole S-Type device rated at 63A. Its built-in time delay ensures upstream discrimination, allowing downstream RCDs to trip first and preventing unnecessary power loss. Ideal for three-phase distribution boards, EV charging hubs, and renewable installs...
A Type Time Delay RCD – 100A 100mA, 4 Pole (WARTD4100-100)
£38.85
The WARTD4100-100 A-Type 100mA Time Delay RCD is a 4 Pole S-Type device rated at 100A for large-scale three-phase boards. Designed for upstream use, its time delay ensures proper discrimination, allowing downstream RCDs to trip first and keeping supply integrity across unaffected circuits. It’s a...
What Is a 3 Phase RCD?
A 3 phase RCD is a 4-pole residual current device that monitors earth leakage across L1, L2, L3 and neutral. If a fault occurs, all poles disconnect together, ensuring full isolation and preventing phase imbalance or equipment damage.
Where 3 Phase RCDs Are Used
- Three-phase distribution boards in commercial and industrial buildings
- Motors, pumps and compressors requiring leakage detection
- HVAC and ventilation systems
- Sub-mains feeding secondary boards
- Machinery circuits where neutral isolation is required
30mA vs 100mA vs 300mA
30mA: Personal protection on circuits feeding equipment directly accessible to users.
100mA: Fire protection or upstream protection where selectivity is needed.
300mA: Commercial/industrial fire protection or main incomer RCDs with selective delay.
Type A vs Type B Three-Phase RCDs
Type A: Detects AC + pulsed DC leakage. Suitable for many three-phase loads.
Type B: Detects smooth DC leakage. Required for VFDs, inverters, large motors and EV/renewables-related equipment.
Why Use a 4-Pole RCD?
Unlike 2-pole devices used on single-phase circuits, a 4-pole RCD gives:
- Simultaneous phase + neutral isolation
- Protection for balanced and unbalanced three-phase loads
- Compliance with three-phase design requirements
- Safe maintenance access without risking partial isolation
Compliance & Standards
All 3 Phase RCDs in this category meet BS EN 61008 / BS EN 61009 requirements and support 18th Edition Wiring Regulations for three-phase leakage protection.
Installer Benefits
3 Phase RCDs offer predictable disconnection, improved safety and full isolation for plant equipment, motors and distribution circuits. Their 4-pole format ensures safe working conditions and stable protection across multi-phase loads.