6 Usable Way Consumer Unit with 63A RCD & 6 MCBs
£80.00 ex. VAT
£96.00 inc. VAT
Your basket
Loading your basket…
Prices exclude VAT. VAT, shipping and discounts are calculated at checkout.
Choose a 6 way consumer unit with six usable outgoing circuit positions and six MCBs matched to your circuit schedule. The two steel-enclosure builds here differ in their incomer: WMCU08/6 has a main switch , while WMCURC8/6 includes...
Choose a 6 way consumer unit with six usable outgoing circuit positions and six MCBs matched to your circuit schedule. The two steel-enclosure builds here differ in their incomer: WMCU08/6 has a main switch, while WMCURC8/6 includes a 63A RCD.
Compare the supplied protection below, then confirm the required MCB ratings and curves before ordering. These are MCB-equipped boards; ask us to check a different build if your job requires individual RCBOs or surge protection.
£80.00 ex. VAT
£96.00 inc. VAT
£38.44 ex. VAT
£46.13 inc. VAT
| Product | What is supplied | Choose when |
|---|---|---|
| WMCU08/6 | Main switch and six MCBs of your choice in a steel enclosure. | Your design specifies a main-switch-and-MCB arrangement, with any required residual-current protection addressed separately. |
| WMCURC8/6 | 63A RCD and six MCBs of your choice in a steel enclosure. | Your design specifies six MCB-protected circuits behind a shared RCD. Confirm the RCD type and sensitivity. |
The main switch provides switching and isolation; it does not provide residual-current protection. The MCBs provide overcurrent protection. On the shared-RCD build, an RCD trip can disconnect the circuits it supplies, which matters where continuity of other circuits is a priority.
Send the required rating and trip curve for each of the six circuits, along with the board quantity, intended location and delivery date. Confirm enclosure dimensions and the complete protection arrangement before ordering. The MCB selection should follow the circuit design, rather than an assumed standard breaker pack.
No. Here, six usable ways means six outgoing circuit positions. The incomer also occupies space, so an enclosure’s overall module count is a different measurement.
The two listed builds are supplied with MCBs, not individual RCBOs. WMCU08/6 does not include an SPD; the WMCURC8/6 listed configuration is a shared RCD plus six MCBs. If surge protection or RCBOs are required, confirm a complete suitable assembly before ordering.
It may suit the required circuit count, but the electrician must also check the supply, earthing, protection and mounting environment. WMCU08/6 is an IP40 indoor unit, so do not assume it is suitable for an exposed outdoor position.
Compare the four-way and eight-way ranges. Check the usable outgoing positions after the chosen devices are fitted, including any allowance for expansion.
Quote WMCU08/6 or WMCURC8/6 and send your six-circuit schedule. Include any RCBO, SPD or enclosure requirements so the proposed build and lead time can be confirmed. Contact Power & Data UK.