A-Type RCBO EV Kit – 2 Way 40 A C Curve (WMEV240C)

  • £28.34
  • 18th Ed. Compliant

    2-Year Warranty

    UK Stock

    Free Delivery £30+

    Secure Payments With

    Google Pay PayPal

    The WMEV240C is a 2-way A-Type RCBO EV Kit fitted with a 40 A C-curve high-immunity Type A RCBO. It provides combined overload, short-circuit and earth-leakage protection (30 mA AC + 6 mA DC) and meets the latest 18th Edition Amendment 2 requirements for EV installations. Designed for high-load single-phase...

    The WMEV240C is a 2-way A-Type RCBO EV Kit fitted with a 40 A C-curve high-immunity Type A RCBO. It provides combined overload, short-circuit and earth-leakage protection (30 mA AC + 6 mA DC) and meets the latest 18th Edition Amendment 2 requirements for EV installations.

    Designed for high-load single-phase chargers or dual EV points (up to ≈ 9 kW), the C-curve profile (5–10 × In) withstands inrush currents from transformer or switch-mode power supplies without nuisance tripping. Each unit is factory-wired and ready to install with dual-pole isolation and clear fault indication.

    Installer Tip: Use the 40 A C-curve for high-power chargers or paired EV sockets drawing up to ≈ 9 kW. If the charger specifies Type B RCD requirements, install with a PME fault unit and surge protection for full compliance.

    • 40 A C-curve Type A RCBO (30 mA AC + 6 mA DC detection)
    • Dual-pole (1P + N) isolation for safe disconnection
    • Compact 2-way steel enclosure with hinged cover
    • High-immunity design prevents false trips on EV loads
    • Complies with BS EN 61009-1 and BS 7671 (A2)
    Part Code Rating Curve Typical Use
    WMEV232C 32 A C 7 kW chargers / standard domestic circuits
    WMEV240C 40 A C High-load or dual-socket EV installations

    Each kit is pre-built and ready for install. For PEN-fault and load-balancing compliance, pair with our PME Fault Detection Unit. Add a Single Module SPD for surge defence if required.

    When should I choose the 40 A C Curve version?

    Use it for high-load or dual-socket EV chargers drawing up to ≈ 9 kW where startup inrush current may trip lower rated devices.

    Is this kit 18th Edition compliant?

    Yes – it includes a Type A RCBO with 30 mA AC + 6 mA DC detection as required by Amendment 2.

    Does it isolate both live and neutral?

    Yes – the 1P + N RCBO provides full dual-pole isolation for safe maintenance and fault clearance.

    Can I add surge protection?

    Yes – fit a Single Module SPD or an upstream surge unit as required by specification.

    Is it suitable for PV as well as EV circuits?

    Yes – the Type A RCBO is bi-directional and approved for EV and solar PV applications.

    • Part Code: WMEV240C
    • Enclosure: 2-way steel with hinged lid
    • Device: Type A RCBO (high immunity)
    • Rated Current (In): 40 A
    • Curve: C
    • Earth Leakage: 30 mA AC + 6 mA DC
    • Breaking Capacity: 6 kA
    • Poles: 1P + N (switched neutral)
    • Standards: BS EN 61009-1; BS 7671:2018 (A2)
    • Typical Use: High-load EV circuits or dual-socket chargers ≈ 9 kW

    The WMEV240C kit is supplied fully assembled for speed on site. Installation and testing must be completed by a qualified electrician.

    • Mount indoors or within an IP-rated enclosure if external
    • Select 40 A C-curve for high-load or dual EV circuits
    • Confirm Zs, R1 + R2 and disconnection times to BS 7671 (A2)
    • Add SPD protection upstream if required by design or manufacturer