Automatic 15% discount for all contractors on all orders over £100 excluding VAT

Pre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping.

The WMEPME12/LB is a steel PME consumer unit with load balancing and kWh metering for a single-phase EV charging circuit. It combines a 40A C Curve Type A RCBO, PME fault monitoring, an adjustable load-management relay and an energy meter in one pre-wired IP40 assembly.

This model is suited to installations where available supply capacity needs to be managed and EV energy use needs to be recorded at the consumer unit. The RCBO provides Type A residual-current and overcurrent protection; any DC residual-current protection required by the charger must be confirmed separately.

Installer Tip: Use the kWh meter for local energy-use visibility. For an IP65 plastic load-balancing unit without the integral meter, compare the WPEPME12/LB.

Key Features

  • 40A C Curve Type A RCBO – overcurrent and Type A residual-current protection
  • Adjustable load management – 10A to 110A setting range via CT monitoring
  • Integrated kWh meter – records energy passing through the EV circuit
  • PME fault monitoring – linked disconnection of line, neutral and protective conductor
  • IP40 steel enclosure – for suitable indoor locations
  • Pre-wired and tested before dispatch

How the Load Management Works

The load-management relay uses a current transformer to monitor demand at the incoming supply. The installer sets a suitable threshold for the installation, allowing the EV charging circuit to be controlled when total demand approaches that limit.

This feature supports supply-demand management; it does not increase the capacity of the incoming supply or replace the required circuit design, protective coordination and commissioning checks.

PME Fault Monitoring

The assembly monitors the supply against the manufacturer’s stated under-voltage and over-voltage thresholds. When a qualifying abnormal condition is detected, its linked switching arrangement disconnects line, neutral and the protective conductor. Under-voltage recovery is automatic, while over-voltage operation requires manual reset.

Compare PME Load-Balancing Units

Model Enclosure Circuit Protection Additional Functions
WMEPME12/LB (This Product) IP40 steel 40A C Curve Type A RCBO Load balancing + kWh meter
WPEPME12/LB IP65 plastic 40A C Curve Type A RCBO Load balancing
Translation missing: en.general.search.loading