Automatic 15% discount for all contractors on all orders over £100 excluding VAT
Pre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping.
The WPKPME08/SP is an IP65 PME consumer unit combining a 40A MCB, PME fault monitoring and a factory-fitted Type 2 SPD. It is intended for single-phase EV charging circuits where the required residual-current protection is provided elsewhere in the completed design.
The MCB provides overload and short-circuit protection; it does not provide residual-current protection. The connected charger and upstream arrangement must therefore be checked carefully before this MCB-based model is selected.
Installer Tip: Choose the MCB version only where suitable residual-current protection is already provided. If the consumer unit needs its own Type A RCBO, compare the WPEPME08/SP.
The built-in monitoring arrangement checks the supply against the manufacturer’s stated under-voltage and over-voltage thresholds. When a qualifying abnormal condition is detected, the assembly operates its linked switching arrangement to disconnect line, neutral and the protective conductor. Under-voltage recovery is automatic; an over-voltage operation requires manual reset.
Final selection still depends on the charger, supply characteristics, earthing arrangement and the protective devices already present. Installation, inspection and testing must be completed by a suitably qualified person in accordance with the manufacturer’s instructions and the current edition of BS 7671.
| Model | Circuit Protection | Included Protection |
|---|---|---|
| WPEPME08/C40 | 40A C Curve Type A RCBO | PME fault detection |
| WPEPME08/SP | 40A C Curve Type A RCBO | PME fault detection + Type 2 SPD |
| WPKPME08/C40 | 40A MCB | PME fault detection |
| WPKPME08/SP (This Product) | 40A MCB | PME fault detection + Type 2 SPD |