PME Fault Detection Consumer Unit – 4 Pole 63A RCBO with SPD (WMEPME10/SP)

  • £165.95 ex VAT £199.14 inc VAT
  • SKU: WMEPME10/SP Out of stock

    The WMEPME10/SP PME Fault Detection Consumer Unit is a larger 10-module metal enclosure fitted with a 4 Pole 63A Type A RCBO and an integrated Type 2 Surge Protection Device (SPD). It provides full PME/PEN fault detection, automatically disconnecting Live, Neutral, and Earth within 5 seconds under dangerous voltage conditions....

    Read full description
    ✓ This item qualifies for free delivery
    Secure PayPal & Google Pay checkout
    Not sure it is the right configuration? Call 01923 969 309

    The WMEPME10/SP PME Fault Detection Consumer Unit is a larger 10-module metal enclosure fitted with a 4 Pole 63A Type A RCBO and an integrated Type 2 Surge Protection Device (SPD). It provides full PME/PEN fault detection, automatically disconnecting Live, Neutral, and Earth within 5 seconds under dangerous voltage conditions. Fully compliant with BS 7671:2018 (18th Edition, Amendment 2), this board eliminates the need for an earth rod while also protecting downstream equipment against transient surges.

    The extra module space compared to the 8-way variant makes it a strong choice for installs where additional wiring room is needed or future expansion is likely. Ideal for EV charger installations where PEN protection and surge resilience are both required.

    Installer Tip: Choose the 10-module variant when you need extra wiring space for tails, isolators, or future expansion. It includes the same RCBO + SPD protection as the WMEPME08/SP but with more room for neat installs.

    Key Features

    • Integrated PEN fault detection – full isolation of Live, Neutral & Earth under fault
    • 63A Type A RCBO – 4 Pole, C Curve, 30mA residual protection
    • Type 2 SPD – shields against transient voltage surges
    • 10-module steel enclosure – IP40 rated, pre-wired, installer-ready
    • No earth rod required – compliant with PME installs under Amendment 2

    Compare PME Fault Detection Variants

    Model Configuration Modules Protection
    WMEPME06/C40 RCBO Only 6 63A 4P RCBO
    WMEPME08/SP RCBO + SPD 8 63A 4P RCBO + Type 2 SPD
    WMEPME10/SP (This Product) RCBO + SPD 10 63A 4P RCBO + Type 2 SPD
    WMEPME10/LB RCBO + SPD + Load Balance 10 63A 4P RCBO + SPD + PME Relay
    WMEPME12/LBK RCBO + SPD + Load Balance + kWh Meter 12 63A 4P RCBO + SPD + PME Relay + Meter

    Do I still need an earth rod with this board?

    No – the integrated PEN fault detection complies with Amendment 2 and eliminates the need for a separate electrode.

    What’s the difference between the 8-module and 10-module SPD models?

    Both include a 63A RCBO and Type 2 SPD. The WMEPME10/SP provides more wiring space, making it better for neat installs or future expansion.

    Is this suitable for EV charger installs?

    Yes – it’s ideal for EV charge points requiring PME protection and surge resilience, with additional room for flexible wiring.

    • Model: WMEPME10/SP
    • Modules: 10
    • Current Rating: 63A (RCBO)
    • RCBO Type: Type A, 4 Pole, C Curve, 30mA
    • SPD: Type 2, 4 Pole
    • Voltage Monitoring: Under-voltage <207V, Over-voltage >253V
    • Isolation Time: ≤5 seconds
    • Reset: Auto (under-voltage), manual reset (over-voltage)
    • Enclosure: IP40 steel, 10-module
    • Dimensions: Width 280mm, Height 235mm, Depth 110mm
    • Short Circuit Rating: 16kA
    • Standards: BS EN 61439-3, BS 7671:2018 A2

    Pre-wired for efficiency, but installation must be completed by a qualified electrician.

    • Mount in a dry, ventilated location
    • Follow the wiring diagram provided
    • Check PEN isolation before commissioning
    • Keep SPD earth conductor short for optimal surge protection