IP40 Metal Garage Consumer Unit – 63A RCD + 6A / 16A MCBs
£33.32 ex. VAT
Was £64.33 ex. VAT
£39.98 inc. VAT
Your basket
Loading your basket…
Prices exclude VAT. VAT, shipping and discounts are calculated at checkout.
The WMEPME10/LB combines PME fault detection, a 40A Type A RCBO and load management in a metal consumer unit. It is intended for EV charging installations where the demand on the incoming supply also needs to be monitored.Load monitoring uses a current transformer on the incoming supply. This helps the...
Read full descriptionAccepted payment methods
The WMEPME10/LB combines PME fault detection, a 40A Type A RCBO and load management in a metal consumer unit. It is intended for EV charging installations where the demand on the incoming supply also needs to be monitored.
Load monitoring uses a current transformer on the incoming supply. This helps the control arrangement account for other large electrical loads, such as electric showers or heating. The current-transformer selection, relay settings and control wiring must be matched to the installation.
Please contact Power & Data UK to confirm SPD fitment, the supplied current transformer and the detailed control arrangement before ordering.
Images are representative of the PME range and may show a different current rating or component arrangement.
Select by the required protection, metering and load-management functions. Confirm the fitted component specifications for your installation.
| Model | Current rating | Configuration |
|---|---|---|
| WMEPME06/C40 | 40A C Curve | RCBO version |
| WMEPME08/SP | 40A C Curve | Type A RCBO with SPD |
| WMEPME10/SP | 40A C Curve | kWh meter; confirm fitted protection devices |
| WMEPME10/LB (this product) | 40A C Curve | Type A RCBO with load management |
| WMEPME12/LBK | Confirm supplied rating | Load balancing and kWh meter listing; confirm exact build |
Browse our PME and PEN fault protection units for other configurations.
Confirm the current transformer rating, RCBO pole arrangement/sensitivity and individual breaking capacity, SPD fitment and control settings with the supplied assembly instructions or contact Power & Data UK.
Installation and commissioning must be carried out by a qualified electrician. Use the instructions supplied with the exact assembly and the charge point, together with the applicable BS 7671 requirements.
The datasheet describes incoming-supply current monitoring and relay-based load management. It does not establish coordinated power sharing between multiple charge points. Confirm the required control arrangement for a multi-charger design.
No. The board is specified with a 40A RCBO. The 10–110A figure is the manufacturer-listed load-management setting range; settings must suit the supplied current transformer and the installation.
Please contact Power & Data UK to confirm the supplied equipment. The matched datasheet establishes a 40A Type A RCBO and load management but does not explicitly specify an SPD or energy meter.
The matched datasheet lists a 12-module enclosure. This is enclosure capacity, not the number of spare outgoing circuits.
Suitability depends on the charge point, earthing arrangement and circuit design. A qualified electrician must select and commission the complete installation using the supplied instructions and the applicable BS 7671 requirements.
Power & Data UK