CATEGORIES

High Immunity RCBO – 6A C Curve, Type A, 30mA (WER06C-030)

£23.50 ex VAT £28.20 inc VAT
SKU: WER06C-030

The WER06C-030 is a 6A C Curve High Immunity Type A RCBO designed to provide combined overload, short-circuit and residual current protection in one compact device. It is a strong fit for circuits where a 6A protective rating is needed but where a C Curve characteristic is preferred due to...

Read full description

Accepted payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Free delivery over £80 Delivery information

Need help choosing the right configuration? Call 01923 969 309

Description

The WER06C-030 is a 6A C Curve High Immunity Type A RCBO designed to provide combined overload, short-circuit and residual current protection in one compact device. It is a strong fit for circuits where a 6A protective rating is needed but where a C Curve characteristic is preferred due to start-up current or circuit conditions.

As part of the Whitecliffe WER High Immunity RCBO range, this model offers Type A protection for AC and pulsating DC residual currents, along with double pole isolation and bi-directional wiring. That makes it well suited to modern consumer units and distribution boards where nuisance tripping resistance and installation flexibility are important.

Installer Tip: A 6A C Curve RCBO can be useful where a low-rated circuit still has a higher inrush characteristic than a standard B Curve circuit. Always size the protective device to suit the actual design current and equipment characteristics.

Key Features

  • 6A C Curve Type A RCBO – combined overload and residual current protection in one device
  • High immunity design – helps reduce nuisance tripping in electrically noisy environments
  • 30mA sensitivity – suitable for additional protection requirements
  • 10kA breaking capacity – suitable for a wide range of domestic and commercial boards
  • Double pole switching – disconnects live and neutral
  • Bi-directional supply – connection from top or bottom
  • DIN rail compatible – fits standard EN 60715 35mm rails
  • Type A protection – detects AC and pulsating DC residual currents

Compare High Immunity RCBOs

Model Rating Curve Typical Use
WER06B-030 6A B Lighting and other low inrush final circuits
WER06C-030 (This Product) 6A C Low-rated circuits where higher inrush tolerance is preferred
WER16B-030 16A B General domestic final circuits with low inrush loads
WER16C-030 16A C Small motors and circuits with moderately higher inrush current
WER20B-030 20A B Domestic final circuits requiring a higher current rating
WER20C-030 20A C Circuits with moderately higher inrush current
WER32B-030 32A B Ring finals and other standard appliance circuits
WER32C-030 32A C Higher demand circuits and loads with greater inrush current
WER40B-030 40A B Higher load circuits with lower inrush characteristics
WER40C-030 40A C Heavier-duty circuits with higher inrush conditions
WER63C-030 63A C Larger commercial or high-load applications
Technical specs
  • SKU: WER06C-030
  • Type: Type A RCBO
  • Rated Current: 6A
  • Trip Curve: C
  • Residual Current Sensitivity: 30mA
  • Poles: 2 Pole
  • Rated Voltage: 230/240V
  • Frequency: 50/60Hz
  • Breaking Capacity: 10kA
  • Impulse Withstand Voltage: 6kV
  • Connection: Top or bottom / bi-directional
  • Mounting: DIN rail EN 60715 (35mm)
  • Standards: IEC 61009-1 / EN 61009-1
Installation notes

Designed for installation in consumer units and distribution boards where combined MCB and RCD protection is required in a single device.

  • Mounts to standard 35mm DIN rail
  • Suitable for top or bottom connection
  • Use the correct rated device for the circuit design current and expected inrush characteristics
  • Terminal connections suitable for cable, U-type busbar and pin-type busbar
  • Installation and testing must be carried out by a qualified electrician
FAQs

What is the difference between WER06B-030 and WER06C-030?

Both are 6A Type A high immunity RCBOs with 30mA sensitivity, but the trip curve is different. B Curve is typically used on lower inrush circuits, while C Curve allows for higher inrush current before tripping.

What does Type A mean on an RCBO?

A Type A RCBO can detect both standard AC residual currents and pulsating DC residual currents, making it more suitable than Type AC devices for many modern circuits.

Why choose a high immunity RCBO?

High immunity devices are designed to reduce nuisance tripping caused by transient voltages or electrical noise, which can be helpful in modern installations with more sensitive equipment.

Can this RCBO be wired from the top or bottom?

Yes. The WER range supports bi-directional connection, so supply can be taken from the top or bottom as required.

Reviews

Power & Data UK

Why buy from Power & Data?

  • Electrical ranges in one place

    Consumer units, circuit protection and ranges for renewable installations.

    Explore the range
  • Speak to P&D

    Have a question before you order? Call our sales team.

    01923 969 309
  • Secure checkout

    Choose from the payment methods available at checkout, with your order total shown before you pay.