A-Type RCBO EV Kit – 2 Way 6 A C Curve (WMEV206C)
18th Ed. Compliant
2-Year Warranty
UK Stock
Free Delivery £30+
Secure Payments With
The WMEV206C is a 2-way A-Type RCBO EV Kit fitted with a 6 A C-curve high-immunity Type A RCBO. It provides overload, short-circuit and earth-leakage protection (30 mA AC + 6 mA DC) to 18th Edition Amendment 2 standards and is ideal for control or low-power EV circuits with brief...
The WMEV206C is a 2-way A-Type RCBO EV Kit fitted with a 6 A C-curve high-immunity Type A RCBO. It provides overload, short-circuit and earth-leakage protection (30 mA AC + 6 mA DC) to 18th Edition Amendment 2 standards and is ideal for control or low-power EV circuits with brief inrush currents.
Unlike a B-curve unit, the C-curve design tolerates startup surges 5–10× rated current, preventing nuisance tripping where inductive or electronic components are present. Compact, pre-assembled and inspection-ready, this kit offers full dual-pole isolation in a durable steel housing.
Installer Tip: Use 6 A C-curve breakers for control gear, signal relays, or EV chargers with internal power supplies prone to small inrush surges. For simple pilot feeds or low-current lines, the 6 A B-curve version is usually sufficient.
- 6 A C-curve Type A RCBO (30 mA AC + 6 mA DC detection)
- Dual-pole (1P + N) isolation for live and neutral conductors
- 2-way compact steel enclosure with hinged cover
- High-immunity design reduces false trips on inrush loads
- Fully compliant with BS EN 61009-1 and BS 7671 (A2)
| Part Code | Rating | Curve | Typical Use |
|---|---|---|---|
| WMEV206B | 6 A | B | Low-load pilot or control EV circuits |
| WMEV206C | 6 A | C | Control or relay-fed circuits with inrush |
| WMEV210C | 10 A | C | Low-rated chargers or auxiliary EV feeds |
Each kit arrives pre-assembled for fast installation. Combine with our PME Fault Detection Unit for PEN compliance and load balancing, or add a Single Module SPD for surge defence.
When should I choose the 6 A C Curve version?
Use it for control circuits or small chargers with electronic power supplies that cause inrush spikes. The C curve prevents nuisance trips.
Is this kit compliant for EV installations?
Yes – the Type A RCBO meets 18th Edition Amendment 2 with 30 mA AC + 6 mA DC leakage protection.
Does it isolate both live and neutral?
Yes – the 1P + N RCBO disconnects both conductors for full isolation and safety.
Can I add surge protection?
Yes – fit a Single Module SPD or upstream surge device where required.
Is it suitable for solar PV as well as EV circuits?
Yes – the Type A RCBO is bi-directional and approved for both EV and PV use.
- Part Code: WMEV206C
- Enclosure: 2-way steel with hinged lid
- Device: Type A RCBO (high immunity)
- Rated Current (In): 6 A
- Curve: C
- Earth Leakage: 30 mA AC + 6 mA DC
- Breaking Capacity: 6 kA
- Poles: 1P + N (switched neutral)
- Standards: BS EN 61009-1; BS 7671:2018 (A2)
- Typical Use: EV control or auxiliary circuits with small inrush current
The WMEV206C is factory-assembled for quick installation. All testing must be performed by a qualified electrician.
- Mount in a dry or sheltered location (IP-rated if external)
- Use C-curve for circuits with inductive or transformer-based loads
- Verify Zs, R1 + R2 and disconnection times to BS 7671 (A2)
- Add SPD protection upstream if required by design spec