A-Type RCBO EV Kit – 2 Way 10 A C Curve (WMEV210C)
18th Ed. Compliant
2-Year Warranty
UK Stock
Free Delivery £30+
Secure Payments With
The WMEV210C is a 2-way A-Type RCBO EV Kit fitted with a 10 A C-curve high-immunity Type A RCBO. It provides overload, short-circuit and earth-leakage protection (30 mA AC + 6 mA DC) in full accordance with 18th Edition Amendment 2 requirements for EV installations. Designed for low-power chargers or...
The WMEV210C is a 2-way A-Type RCBO EV Kit fitted with a 10 A C-curve high-immunity Type A RCBO. It provides overload, short-circuit and earth-leakage protection (30 mA AC + 6 mA DC) in full accordance with 18th Edition Amendment 2 requirements for EV installations.
Designed for low-power chargers or control supplies that experience brief startup surges, the C-curve profile offers 5–10 × In tolerance to prevent nuisance tripping. It’s pre-assembled in a durable 2-way steel enclosure with dual-pole isolation and clear fault indication.
Installer Tip: Use 10 A C-curve kits for compact chargers or control modules with small transformers or power supplies. For standard 3.6 kW units, a 16 A B-curve is usually more appropriate.
- 10 A C-curve Type A RCBO (30 mA AC + 6 mA DC detection)
- Dual-pole (1P + N) isolation for live and neutral conductors
- Compact 2-way steel enclosure with hinged lid
- High-immunity design minimises false trips on inrush loads
- Complies with BS EN 61009-1 and BS 7671 (A2)
| Part Code | Rating | Curve | Typical Use |
|---|---|---|---|
| WMEV206C | 6 A | C | Control gear / pilot circuits with inrush |
| WMEV210C | 10 A | C | Low-rated EV chargers / control supplies |
| WMEV216C | 16 A | C | Standard EV chargers with transformer input |
Each kit is pre-built and ready to install. Combine with our PME Fault Detection Unit for PEN compliance and load balancing, and add a Single Module SPD for surge defence where required.
When should I use the 10 A C Curve version?
Use it for low-power chargers or control circuits that draw brief inrush currents. It prevents nuisance tripping better than a B-curve.
Is this kit 18th Edition compliant?
Yes – it includes a Type A RCBO with 30 mA AC + 6 mA DC detection as required under Amendment 2.
Does it isolate both live and neutral?
Yes – the 1P + N RCBO disconnects both conductors for safe isolation and maintenance.
Can I add surge protection?
Yes – install our Single Module SPD or an upstream surge unit if required.
Is it suitable for PV as well as EV?
Yes – the Type A RCBO is bi-directional and approved for EV and solar PV circuits.
- Part Code: WMEV210C
- Enclosure: 2-way steel with hinged lid
- Device: Type A RCBO (high immunity)
- Rated Current (In): 10 A
- Curve: C
- Earth Leakage: 30 mA AC + 6 mA DC
- Breaking Capacity: 6 kA
- Poles: 1P + N (switched neutral)
- Standards: BS EN 61009-1; BS 7671:2018 (A2)
- Typical Use: Low-rated EV chargers or auxiliary circuits with moderate inrush
The WMEV210C kit is factory-assembled for speed on site. All testing and verification must be carried out by a qualified electrician.
- Mount in a dry indoor or IP-rated location if outdoors
- Use C-curve for circuits with small transformers or inductive loads
- Confirm Zs and disconnection times to BS 7671 (A2)
- Add SPD upstream if required by site specification