The WMCURC8/6 six usable way consumer unit brings a 63A RCD and six MCBs of your choice together in a steel enclosure with a drop-down lid. It gives installers a supplied board configuration to match their circuit schedule, reducing the need to source the enclosure and each protective device separately.

Choose this board when the installation design calls for six outgoing circuits protected by MCBs behind a shared RCD. The six usable ways refer to the outgoing circuit positions; the fitted RCD is additional to those six positions.

What this configuration gives you

  • 63A RCD incomer: residual current protection for the connected circuit group.
  • Six selectable MCBs: match each outgoing breaker rating and trip curve to the circuit design.
  • Steel enclosure with drop-down lid: the board and devices are supplied together for an organised installation.
  • A defined six-circuit layout: useful when matching a small distribution board to an agreed circuit schedule.

The MCBs provide overcurrent protection; the shared RCD provides residual current protection. An RCD trip can disconnect all circuits it supplies. Where continuity of other circuits matters, discuss a board with individual RCBO protection before ordering.

Specify your six MCBs before ordering

Before placing the order, contact Power & Data UK quoting WMCURC8/6. Send the required rating and trip curve for each of the six circuits, the quantity of boards and your required delivery date. Confirm the RCD type and sensitivity, enclosure dimensions and any additional protection required as part of that specification.

Compare six-way and smaller consumer units

Compare supplied protection and usable outgoing ways
Product Supplied configuration Choose when
WMCURC8/6 — this product 63A RCD + six MCBs; six usable outgoing ways The circuit design calls for a shared RCD and six MCB-protected circuits.
WMCU08/6 Main switch + six MCBs; six usable outgoing ways A main-switch-and-MCB configuration is specified, with residual current protection addressed in the installation design.
WMCURC6/4 RCD + four MCBs; four usable outgoing ways Only four outgoing circuits are needed in an RCD-equipped board.

Need surge protection, individual RCBOs or a different number of circuits? Ask about a board built to your circuit schedule. You can also browse the consumer unit range to compare other supplied configurations.