CATEGORIES

Circuit Protection Devices – MCBs, RCDs & RCBOs

Shop circuit protection devices for domestic, commercial and specialist installations, including MCBs, RCDs, RCBOs and surge protection. Use the filters to narrow the range by device type, rating and application.

Device selection depends on the circuit design, load characteristics, prospective fault current, required residual-current response and the equipment manufacturer’s instructions.

Quick guide: MCBs provide overcurrent protection; RCDs respond to residual current; RCBOs combine both functions for individual circuits. RCD type, trip curve, current rating and breaking capacity must be selected for the installation.

  • MCBs: B, C and D curves for different load and inrush characteristics
  • RCDs: Type A, Type B and specialist time-delay options
  • RCBOs: combined overcurrent and residual-current protection per circuit
  • Specialist protection: high-immunity devices, AFDDs and surge protection
Showing 73 to 84 of 197 items
✓ In stock SKU: WRT125C-030

Type A RCBO – 25A C Curve, 30mA

£14.50 ex VAT £17.40 inc VAT

The WCED WRT125C-030 is a 25A C Curve Type A RCBO with 30mA residual current sensitivity and a 10kA breaking capacity. It combines overload,...

✓ In stock SKU: WRT125B-030

Type A RCBO – 25A B Curve, 30mA

£14.50 ex VAT £17.40 inc VAT

The WCED WRT125B-030 is a 25A B Curve Type A RCBO with 30mA residual current sensitivity and a 10kA breaking capacity. It combines overload,...

✓ In stock SKU: WEV263B-030

63A 30mA Type B RCD (WEV263B-030)

£154.70 ex VAT £185.64 inc VAT

WEV263B-030 is a 63A 30mA Type B RCD designed for applications where smooth DC residual currents and higher-frequency AC residual currents may be present....

✓ In stock SKU: WRT106B-030

Type A RCBO – 6A B Curve, 30mA

£14.50 ex VAT £17.40 inc VAT

The WCED WRT106B-030 is a 6A B Curve Type A RCBO with 30mA residual current sensitivity and a 10kA breaking capacity. It combines overload,...

✓ In stock SKU: WKC280B

80A 2 Pole 10kA MCB – B Curve (WKC280B)

£9.08 ex VAT £10.90 inc VAT

The WKC280B is an 80A 2 Pole 10kA Miniature Circuit Breaker (MCB) designed to provide dependable overload and short-circuit protection for high-load single-phase circuits,...

✓ In stock SKU: WKC132C

1 Pole 10kA MCB 32A C Curve WKC132C

£5.00 ex VAT £6.00 inc VAT

The WCED WKC Series 10kA Miniature Circuit Breakers (MCBs) are high-performance devices designed for precise overcurrent detection and short-circuit protection. Built to handle demanding...

✓ In stock SKU: WKC150C

1 Pole 10kA MCB 50A C Curve WKC150C

£5.00 ex VAT £6.00 inc VAT

The WCED WKC Series 10kA Miniature Circuit Breakers (MCBs) are high-performance devices designed for precise overcurrent detection and short-circuit protection. Built to handle demanding...

✓ In stock SKU: WKC140B

1 Pole 10kA MCB 40A B Curve WKC140B

£5.00 ex VAT £6.00 inc VAT

The WCED WKC Series 10kA Miniature Circuit Breakers (MCBs) are high-performance devices designed for precise overcurrent detection and short-circuit protection. Built to handle demanding...

✓ In stock SKU: WMC106C

6kA MCB – 6A 1 Pole C Curve (WMC106C)

£2.20 ex VAT £2.64 inc VATWas £3.40 ex VAT

The WMC106C is a 6 A single-pole 6 kA Miniature Circuit Breaker (MCB) providing dependable overcurrent and short-circuit protection for lighting and auxiliary circuits...

✓ In stock SKU: WMC150C

6kA MCB – 50A 1 Pole C Curve (WMC150C)

£2.20 ex VAT £2.64 inc VATWas £2.99 ex VAT

The WMC150C is a 50 A single-pole 6 kA Miniature Circuit Breaker (MCB) providing reliable overcurrent and short-circuit protection for feed circuits, plant equipment...

Choosing the Right Circuit Protection

Start with the circuit design and connected equipment—not a device label in isolation. The protective device must suit the load, conductor capacity, earthing arrangement, prospective fault current and any residual-current characteristics identified by the equipment manufacturer. Installation and verification should be completed by a competent electrical professional to the applicable edition of BS 7671.

MCBs

Miniature circuit breakers provide protection against overload and short-circuit current. Select the current rating, trip curve and breaking capacity from the installation design and load characteristics.

Shop MCBs →

RCDs

Residual current devices disconnect when the monitored current imbalance reaches their operating threshold. The correct type and sensitivity depend on the application and expected residual-current waveform.

Shop RCDs →

RCBOs

RCBOs combine overcurrent and residual-current protection in one device. Per-circuit protection can improve fault discrimination and limit disruption elsewhere in the installation.

Shop RCBOs →

Specification Checklist

  • Rated current: coordinate with design current, conductor capacity and upstream protection.
  • Trip curve: select for the load’s normal operating and inrush characteristics.
  • Breaking capacity: verify against the prospective fault current at the installation point.
  • RCD type: match the residual-current waveform and manufacturer requirements; Type B is used where smooth DC residual current can occur.
  • Poles and neutral switching: confirm the supply arrangement and required conductor isolation.

Guides for Device Selection

Related Categories

Surge ProtectionHigh Immunity RCBOsType B RCDsArc Fault DetectionElectrical Enclosures

Trade support: UK-stocked products, manufacturer-backed specifications and fast dispatch. Check each product page for standards, ratings, stock status and delivery details before ordering.