Main Switch Consumer Unit – WME14/MS100 (14 Module, 100A)
The WME14/MS100 Main Switch Consumer Unit is a 14-module metal enclosure supplied with a 100A main switch incomer. With 12 usable ways, it offers...
Your basket
Loading your basket…
Prices exclude VAT. VAT, shipping and discounts are calculated at checkout.
Shop circuit protection devices for domestic, commercial and specialist installations, including MCBs, RCDs, RCBOs and surge protection. Use the filters to narrow the range by device type, rating and application.
Device selection depends on the circuit design, load characteristics, prospective fault current, required residual-current response and the equipment manufacturer’s instructions.
Quick guide: MCBs provide overcurrent protection; RCDs respond to residual current; RCBOs combine both functions for individual circuits. RCD type, trip curve, current rating and breaking capacity must be selected for the installation.
The WME14/MS100 Main Switch Consumer Unit is a 14-module metal enclosure supplied with a 100A main switch incomer. With 12 usable ways, it offers...
The WME12/MS100 Main Switch Consumer Unit is a 12-module metal enclosure supplied with a 100A main switch incomer. With 10 usable ways, it’s a...
The WME22100TR/SP is a 22-module metal twin RCD consumer unit with a 100A main switch, two 100A, 30mA Type A RCDs and a Type...
The WME2280TR/SP is a 22-module metal twin RCD consumer unit with a 100A main switch, two 80A, 30mA Type AC RCDs and a Type...
The WME1880TR/SP Twin RCD Metal Consumer Unit is an 18-module split-load board supplied with a 100A main switch, two 80A RCDs, and a factory-fitted...
The WME22100TR is a 22-module metal twin RCD consumer unit with a 100A main switch, two 100A RCDs. It provides 16 usable ways for...
The WME2280TR is a 22-module metal twin RCD consumer unit with a 100A main switch, two 80A RCDs. It provides 16 usable ways for...
The WME18100TR Twin RCD Metal Consumer Unit is an 18-module split-load board designed for larger domestic and light commercial installs. Fitted with a 100A...
RCBO Consumer Unit Boards with 100A Main Switch & Twin RCDs. These Twin RCD metal consumer units are built for domestic and light commercial...
The WME1663TR Twin RCD Metal Consumer Unit is a 16-module split-load board built for domestic and light commercial installs where RCD separation and Amendment...
The WME1463TR Twin RCD Metal Consumer Unit is a 14-module split-load board designed for domestic and light commercial installs where compliance, RCD separation, and inspection...
The WFD140B-030 is a 40A, B Curve Arc Fault Detection (AFDD) RCBO, designed to deliver maximum protection against arc faults, earth leakage, overload, and...
Start with the circuit design and connected equipment—not a device label in isolation. The protective device must suit the load, conductor capacity, earthing arrangement, prospective fault current and any residual-current characteristics identified by the equipment manufacturer. Installation and verification should be completed by a competent electrical professional to the applicable edition of BS 7671.
Miniature circuit breakers provide protection against overload and short-circuit current. Select the current rating, trip curve and breaking capacity from the installation design and load characteristics.
Residual current devices disconnect when the monitored current imbalance reaches their operating threshold. The correct type and sensitivity depend on the application and expected residual-current waveform.
RCBOs combine overcurrent and residual-current protection in one device. Per-circuit protection can improve fault discrimination and limit disruption elsewhere in the installation.
Surge ProtectionHigh Immunity RCBOsType B RCDsArc Fault DetectionElectrical Enclosures
Trade support: UK-stocked products, manufacturer-backed specifications and fast dispatch. Check each product page for standards, ratings, stock status and delivery details before ordering.