High Immunity RCBO – 20A B Curve, Type A, 30mA
£23.50 ex. VAT
£28.20 inc. VAT
Your basket
Loading your basket…
Prices exclude VAT. VAT, shipping and discounts are calculated at checkout.
The WRN40B-030 is a 40A Type A RCBO in a compact single-module, 2-pole design. It combines residual current (RCD) and overcurrent (MCB) protection in one device, detecting both AC and pulsating DC leakage faults. With a switched neutral built in, this RCBO fully isolates live and neutral conductors during a...
Read full descriptionAccepted payment methods
The WRN40B-030 is a 40A Type A RCBO in a compact single-module, 2-pole design. It combines residual current (RCD) and overcurrent (MCB) protection in one device, detecting both AC and pulsating DC leakage faults. With a switched neutral built in, this RCBO fully isolates live and neutral conductors during a fault, helping installers meet BS 7671 (18th Edition) compliance while keeping healthy circuits energised.
Installer Tip: The 40A B-curve RCBO is often used for high-load subcircuits and small distribution boards where both overload and earth leakage protection must be combined into one device.
| SKU | WRN40B-030 |
| Device Type | Type A RCBO |
| Current Rating | 40A |
| Curve | B Curve |
| Residual Current | 30mA |
| Poles | 2 Pole (Live + Neutral switched) |
| Module Width | 1 (18mm) |
| Dimensions | 18 × 82 × 77mm |
| Mounting | DIN rail |
| Standards | BS EN 61009-1, BS 7671 |
The WRN40B-030 fits any standard UK DIN rail consumer unit. Installation must be carried out by a qualified electrician, with final testing using a calibrated RCBO tester to confirm tripping performance.
It’s typically used for higher-demand circuits or small sub-distribution boards requiring both residual and overload protection.
Yes. The WRN40B-030 fully isolates both live and neutral conductors during a fault, increasing safety for maintenance and compliance.
Yes. The compact 18mm module width makes it suitable for most UK DIN rail boards.
B-curve devices are designed for circuits with low inrush currents (e.g. lighting, general domestic loads). For motor-heavy circuits, a C-curve alternative is recommended.
Yes. The WRN40B-030 is certified to BS EN 61009-1 and meets 18th Edition Amendment 2 wiring regulations.
For heavier loads or circuits with high inrush, consider the WRN32C-030 C Curve RCBO for better inrush handling.