    The WKC440C is a 40A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its C Curve trip profile, it is built for inductive load circuits such as motors, pumps, HVAC systems, EV chargers, and commercial lighting in three-phase boards, EV installations, and solar PV...

    The WKC440C is a 40A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its C Curve trip profile, it is built for inductive load circuits such as motors, pumps, HVAC systems, EV chargers, and commercial lighting in three-phase boards, EV installations, and solar PV setups.

    Rated to 10kA breaking capacity, the WKC440C provides safe overload and short-circuit protection while ensuring complete neutral isolation. It is DIN-rail mounted, bi-directional, and compliant with BS 7671 (18th Edition).

    Installer Tip: A 40A C Curve is widely used for larger inductive loads such as HVAC compressors, pumps, and EV distribution panels. Ensure that prospective fault current does not exceed 10kA.

    Key Features

    • 40A 4 Pole MCB – C Curve characteristic
    • 10kA breaking capacity – robust for commercial & industrial boards
    • Neutral isolation: full 4P switching (L1, L2, L3, N)
    • Bi-directional feed: install top or bottom
    • DIN-rail mounted: 18mm width per pole
    • Meets BS 7671 (18th Edition) compliance

    Compare WKC 4 Pole 10kA MCBs (C Curve)

    Model Rating Curve Breaking Capacity
    WKC432C 32A C Curve 10kA
    WKC440C (This Product) 40A C Curve 10kA
    WKC450C 50A C Curve 10kA
    WKC463C 63A C Curve 10kA

    What applications is the WKC440C used for?

    It’s widely used for HVAC compressors, pumps, and larger inductive loads in commercial and industrial systems.

    Why use a C Curve instead of B Curve?

    C Curve breakers handle higher inrush currents, making them suitable for inductive loads where B Curve breakers may nuisance trip.

    Can this be used for EV charger distribution?

    Yes — the 40A C Curve is ideal for EV distribution boards with moderate inrush loads, provided the system fault level ≤10kA.

    Does this product meet compliance standards?

    Yes, the WKC440C is compliant with BS 7671 (18th Edition) and IEC/EN 60898-1.

    • Model: WKC440C
    • Type: Miniature Circuit Breaker (MCB)
    • Current Rating: 40A
    • Curve: C Curve
    • Poles: 4P (L1, L2, L3 + Neutral)
    • Breaking Capacity: 10kA
    • Mounting: 35mm DIN rail, 18mm per module
    • Dimensions: Approx. 72mm (W) x 90mm (H) x 77mm (D)
    • Standards: BS 7671 (18th Edition), IEC/EN 60898-1
    • Brand: WCED

    The WKC440C must be installed by a qualified electrician in line with BS 7671 regulations.

    • Mount on 35mm DIN rail (18mm per pole)
    • Ensure prospective fault current ≤10kA
    • For inductive/moderate inrush loads (C Curve)
    • Tighten terminals to recommended torque
    • Allow sufficient space for 4P breakers in the enclosure