CATEGORIES

Twin RCD Metal Consumer Unit – WME2280TR/SP (22 Module, 80A, with Surge Protection)

£106.45 ex VAT £127.74 inc VAT
SKU: WME2280TR/SP

The WME2280TR/SP is a 22-module metal twin RCD consumer unit with a 100A main switch, two 80A, 30mA Type AC RCDs and a Type 2 surge protection device (SPD). It provides 15 usable ways for the outgoing circuit arrangement.This is the surge-protected 80A RCD version. WCED specifies Type AC residual-current...

Read full description

Accepted payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Free delivery over £80 Delivery information

Need help choosing the right configuration? Call 01923 969 309

Description

The WME2280TR/SP is a 22-module metal twin RCD consumer unit with a 100A main switch, two 80A, 30mA Type AC RCDs and a Type 2 surge protection device (SPD). It provides 15 usable ways for the outgoing circuit arrangement.

This is the surge-protected 80A RCD version. WCED specifies Type AC residual-current protection at 30mA for this model. Select the RCD type and outgoing devices against the connected loads and the circuit design; an included SPD does not establish suitability for every application.

Key details

  • Module size: 22
  • Usable ways: 15
  • Main switch: 100A
  • RCDs: 2 × 80A, 30mA Type AC
  • Surge protection: Type 2 SPD included
  • Dimensions (W × H × D): 448 × 240 × 112mm

Images show a representative unit from the range. The supplied RCD ratings and SPD fitment for WME2280TR/SP are those stated in this listing.

Compare the 22-module twin RCD boards

All four have a 100A main switch and published dimensions of 448 × 240 × 112mm (W × H × D). The fitted RCD ratings and surge protection differ.

Model Usable ways RCDs SPD
WME2280TR 16 2 × 80A; type to confirm Not included
WME2280TR/SP (this product) 15 2 × 80A, 30mA Type AC Type 2 included
WME22100TR 16 2 × 100A; type to confirm Not included
WME22100TR/SP 15 2 × 100A, 30mA Type A Type 2 included

Browse the metal consumer unit range for other sizes, or contact Power & Data UK to check the supplied configuration and approved outgoing devices.

Technical specs
  • Part code: WME2280TR/SP
  • Enclosure: metal, split-load consumer unit
  • Module size: 22
  • Usable ways: 15
  • Main switch: 100A
  • RCDs: 2 × 80A, 30mA Type AC
  • Surge protection: Type 2 SPD included
  • Dimensions (W × H × D): 448 × 240 × 112mm
  • Rated voltage / frequency: 230V / 50Hz
  • Ingress protection: IP40
  • Incoming terminal capacity: 35mm² maximum
  • Terminal type: cage clamp
  • Device mounting: 35mm DIN rail
  • Ambient temperature: -25°C to +40°C
  • SPD status indication: green: good; red: replace, following the supplied device instructions
  • Enclosure standard: manufactured and tested to BS EN 61439-3, as stated by WCED
  • RCD standard: BS EN 61008-1, as stated by WCED
  • SPD standard: BS EN 61643-11, as stated by WCED

The module count describes the enclosure format; usable ways describe the space available in the listed configuration. Confirm the required outgoing protective devices and their approved layout when ordering.

Installation notes

A qualified electrician must select, install and test the WME2280TR/SP against the circuit design and the supplied assembly and device instructions.

  • Plan the outgoing devices around the manufacturer's 15 usable ways and approved board/busbar arrangement.
  • Check the main-switch, RCD and supply protective-device ratings. The ratings of two RCDs must not be added together to determine the board's permitted load.
  • Confirm that 30mA Type AC RCD protection is appropriate for the connected loads and required disconnection performance.
  • Follow the supplied SPD wiring, conductor and protective-device coordination instructions.
  • Follow the supplied mounting, cable-entry, earthing, terminal-capacity and tightening-torque instructions.
  • Complete the required inspection, testing and circuit labelling before putting the board into service.
FAQs

What does WME2280TR/SP include?

The documented configuration includes a 100A main switch and 2 × 80A, 30mA Type AC RCD protection plus a Type 2 SPD, in a 22-module metal enclosure with 15 usable ways.

Why are there 15 usable ways in a 22-module enclosure?

The fitted incoming devices occupy part of the enclosure. WCED lists 16 usable ways for these standard 22-module twin RCD boards and 15 for the /SP versions. The final circuit count depends on the width and approved arrangement of the outgoing devices.

Which RCD type is fitted?

WCED specifies two 80A, 30mA Type AC RCDs for WME2280TR/SP. The RCD type must suit the connected loads; it should not be assumed from another model in the range.

Does the SPD make this suitable for EV or solar circuits?

The Type 2 SPD provides surge protection. The installation still needs the appropriate residual-current, overcurrent and any other application-specific protection. Confirm the complete design before selecting this board.

Reviews

Power & Data UK

Why buy from Power & Data?

  • Electrical ranges in one place

    Consumer units, circuit protection and ranges for renewable installations.

    Explore the range
  • Speak to P&D

    Have a question before you order? Call our sales team.

    01923 969 309
  • Secure checkout

    Choose from the payment methods available at checkout, with your order total shown before you pay.