The WMC116B is a 16 A single-pole 6 kA Miniature Circuit Breaker (MCB) designed for socket and small-power radial circuits. It combines dependable overcurrent and short-circuit protection with a B-curve tripping characteristic that responds at 3–5 × rated current — ideal for domestic and light-commercial loads with low inrush. Manufactured...

Read full description

Accepted payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Free delivery over £80 Delivery information

Need help choosing the right configuration? Call 01923 969 309

Description

The WMC116B is a 16 A single-pole 6 kA Miniature Circuit Breaker (MCB) designed for socket and small-power radial circuits. It combines dependable overcurrent and short-circuit protection with a B-curve tripping characteristic that responds at 3–5 × rated current — ideal for domestic and light-commercial loads with low inrush.

Manufactured to BS EN 60898, the WMC116B fits Whitecliffe consumer units and standard DIN-rail enclosures. It offers long mechanical life and precise thermal-magnetic tripping for reliable circuit protection across 8 000 electrical operations.

Installer Tip: Use 16 A B-curve breakers for socket circuits and small appliances fed by radials or rings. Confirm Zs values and protective coordination to ensure compliance with BS 7671 disconnection times.

  • 16 A rated current with B-curve (3–5 × In) tripping
  • 6 kA breaking capacity at 230/400 V AC
  • Single-pole design – 18 mm module width
  • DIN-rail mounted for consumer units and distribution boards
  • Complies with BS EN 60898 and BS 7671 (18th Edition A2)
  • Tested service life: 20 000 mechanical / 8 000 electrical operations
  • Contact-position indicator for easy visual status check
Part Code Rating Curve Typical Use
WMC106B 6 A B Lighting and low-load socket circuits
WMC116B 16 A B Socket or small-power radial circuits
WMC132B 32 A B Cookers and high-load domestic circuits
WMC116C 16 A C Radials with higher inrush (e.g. motors, compressors)

The WMC116B provides dependable 6 kA fault protection for socket and small-power circuits. For motor or EV installations requiring greater inrush tolerance, view our C Curve MCB range or upgrade to Type A RCBOs for combined overcurrent and earth-fault protection.

Technical specs
  • Part Code: WMC116B
  • Type: Single Pole MCB
  • Rated Current (In): 16 A
  • Curve: B (3–5 × In tripping characteristic)
  • Rated Voltage (Ue): 230/400 V AC
  • Rated Frequency: 50/60 Hz
  • Breaking Capacity (Icn): 6 kA
  • Insulation Voltage (Ui): 500 V
  • Impulse Withstand Voltage (Uimp): 4 kV
  • Dielectric Test Voltage: 2 kV for 1 minute
  • Thermal Reference Temp: 30 °C
  • Operating Temperature: –5 °C to +40 °C (avg < 35 °C)
  • Mechanical Life: 20 000 operations
  • Electrical Life: 8 000 operations
  • Mounting: 35 mm DIN rail (1 module width)
  • Standards: BS EN 60898; BS 7671:2018 (Amendment 2)
  • Typical Applications: Socket outlets, ring final and small power radials in domestic or light-commercial systems
Installation notes

Install the WMC116B in a suitable consumer unit or distribution board by a qualified electrician. Always match the rating and curve type to the circuit design.

  • Mount securely on 35 mm DIN rail with correct busbar alignment
  • Select B-curve for socket or radial circuits with low inrush
  • Verify rated current (16 A) and cable size meet design requirements
  • Use C-curve devices for motors or compressor loads
  • Tighten terminals to manufacturer torque values and log test results on EIC forms
FAQs

What does 16 A mean on this MCB?

It indicates the breaker’s rated current. The WMC116B will carry 16 A continuously and trip if the circuit exceeds this value beyond its thermal tolerance.

When should I use a 16 A B Curve breaker?

B-curve MCBs trip quickly at low fault multiples (3–5 × In) and are ideal for general socket and lighting circuits without large inrush currents.

Are these compatible with Whitecliffe consumer units?

Yes — the WMC116B fits all Whitecliffe boards and most standard 18 mm DIN-rail enclosures.

Can this be used for outbuilding or garage circuits?

Yes, if installed in a suitable enclosure with appropriate IP rating. Use our IP65 plastic enclosure for external setups.

What if the circuit has motors or compressors?

Choose a C Curve MCB which allows for higher inrush currents (5–10 × In) without nuisance tripping.

Reviews

Power & Data UK

Why buy from Power & Data?

  • Electrical ranges in one place

    Consumer units, circuit protection and ranges for renewable installations.

    Explore the range
  • Speak to P&D

    Have a question before you order? Call our sales team.

    01923 969 309
  • Secure checkout

    Choose from the payment methods available at checkout, with your order total shown before you pay.