4 Way Metal EV Protection Unit – 32A B Curve A-Type RCBO + SPD
£34.90 ex. VAT
£41.88 inc. VAT
Your basket
Loading your basket…
Prices exclude VAT. VAT, shipping and discounts are calculated at checkout.
The WMRC40BSP metal EV consumer unit brings a 40A B curve Type A RCBO and Type 2 surge protection together in a compact indoor enclosure. It gives installers a clearly specified protection assembly for an EV charger circuit, with twin-handle fault indication to help make subsequent fault finding easier. Why...
Read full descriptionAccepted payment methods
The WMRC40BSP metal EV consumer unit brings a 40A B curve Type A RCBO and Type 2 surge protection together in a compact indoor enclosure. It gives installers a clearly specified protection assembly for an EV charger circuit, with twin-handle fault indication to help make subsequent fault finding easier.
Choose this model where the circuit design specifies 40A B curve overcurrent protection and Type A residual-current protection. B curve describes the overcurrent characteristic; it does not mean Type B RCD protection. Confirm the charger’s DC residual-current and open-PEN protection arrangements separately before ordering.
View the Whitecliffe WMRC datasheet (PDF) for the enclosure dimensions, connection diagrams and technical details.
| Product | Supplied configuration | Choose when |
|---|---|---|
| WMRC40BSP — this product | 40A B curve Type A RCBO + Type 2 SPD; metal IP40 | The design specifies 40A B curve protection in a dry indoor location. |
| WMRC32BSP | 32A B curve Type A RCBO + Type 2 SPD; metal IP40 | The specified protective-device rating is 32A. |
| WMRC40CSP | 40A C curve Type A RCBO + Type 2 SPD; metal IP40 | The circuit design and disconnection requirements call for C curve. |
| WPRC40BSP | 40A B curve Type A RCBO + Type 2 SPD; plastic IP65 | An IP65 enclosure is required for the installation location. |
Ordering the specified 40A B curve indoor version? Select your quantity and add WMRC40BSP to your basket. For help comparing configurations or checking delivery for a scheduled job, contact Power & Data UK with the charger model, installation location and required date. You can also browse all EV protection units.
Installation and commissioning must be carried out by a qualified electrician using the instructions supplied with the assembly and the EV charger.
It is the 40A B curve, Type A RCBO version with Type 2 surge protection. Match those requirements to the charger manufacturer’s instructions and the circuit design. Charger power alone does not determine the correct protective device.
No. Type A describes AC and pulsating DC residual-current detection. Do not assume this assembly replaces any separate DC detection required by the charger installation. Confirm what is built into the charger and what external protection its manufacturer specifies.
Open-PEN detection is not part of the listed RCBO-and-SPD configuration. Your installer must confirm the earthing arrangement and whether the charger or a separate device provides any required open-PEN protection.
The WMRC40BSP enclosure is IP40 and intended for a suitable dry indoor location. Compare the IP65 WPRC40BSP if your design requires an enclosure with greater protection against water ingress.
Whitecliffe describes the black handle as the MCB function and the white handle as the RCD function. A black-handle-only trip indicates overload or short circuit; both handles tripping indicates a residual-current fault. Faults should be investigated by a qualified electrician.
No. It describes the enclosure capacity. The supplied RCBO and SPD occupy space within it; this is a dedicated protection assembly, not a board advertised with four spare outgoing ways.
Power & Data UK
Consumer units, circuit protection and ranges for renewable installations.
Explore the rangeChoose from the payment methods available at checkout, with your order total shown before you pay.