A Type Time Delay RCD – 63A 100mA, 2 Pole (WARTD263-100)

  • £36.75
  • 18th Ed. Compliant

    2-Year Warranty

    UK Stock

    Free Delivery £80+

    Secure Payments With

    Google Pay PayPal

    WARTD263-100 is a 2 pole A-type 100mA time delay RCD designed for use where two RCDs are installed in series and discrimination is required. Its built-in time delay helps ensure the upstream device only trips when appropriate, allowing the downstream protective device to operate first during a fault. This makes...

    WARTD263-100 is a 2 pole A-type 100mA time delay RCD designed for use where two RCDs are installed in series and discrimination is required. Its built-in time delay helps ensure the upstream device only trips when appropriate, allowing the downstream protective device to operate first during a fault.

    This makes it well suited to distribution arrangements where selective coordination is needed, including installations connected to EV systems and solar or renewable applications. As an A-type device, it provides residual current protection for AC and pulsating DC components.

    Installer Tip: Time delay RCDs are generally used in upstream positions only. They should be selected as part of a coordinated protection strategy where discrimination between devices is required.

    Key Features

    • 2 pole A-type time delay RCD – WARTD263-100
    • 63A rated current
    • 100mA sensitivity
    • Time delay operation – supports upstream discrimination
    • Residual current characteristics: A-type
    • Suitable for solar and EV applications
    • 6kA rated conditional short-circuit current
    • Dimensions: 36 x 82 x 70mm

    Compare Time Delay RCD Variants

    Model Poles Rated Current Sensitivity Type
    WARTD263-100 (This Product) 2 Pole 63A 100mA A-Type, Time Delay
    WARTD280-100 2 Pole 80A 100mA A-Type, Time Delay
    WARTD2100-100 2 Pole 100A 100mA A-Type, Time Delay
    WARTD463-100 4 Pole 63A 100mA A-Type, Time Delay
    WARTD480-100 4 Pole 80A 100mA A-Type, Time Delay
    WARTD4100-100 4 Pole 100A 100mA A-Type, Time Delay

    What is a 100mA time delay RCD used for?

    It is typically used where two RCDs are installed in series and upstream discrimination is required, so the downstream device trips first during a fault.

    Is WARTD263-100 suitable for solar or EV installations?

    Yes. The catalogue identifies this time delay RCD range as suitable for solar and EV applications where coordinated protection is required.

    Is this a 2 pole device?

    Yes. WARTD263-100 is a 2 pole A-type time delay RCD rated at 63A with 100mA sensitivity.

    Does this device provide surge protection?

    No. This is a time delay RCD only. Surge protection must be provided separately where required.

    What is the size of WARTD263-100?

    The dimensions are 36 x 82 x 70mm.

    • Product Code: WARTD263-100
    • Type: A-Type Time Delay RCD
    • Rated Current: 63A
    • Sensitivity: 100mA
    • Poles: 2 Pole
    • Rated Operational Voltage: 230/400V
    • Frequency: 50Hz
    • Rated Conditional Short-Circuit Current: 6kA
    • Mechanical Durability: 4000 cycles
    • Electrical Durability: 2000 cycles
    • Ingress Protection: IP20
    • Dimensions: 36 x 82 x 70mm
    • Standard: BS EN 61008-1
    • Recommended Terminal Torque: 2.5Nm

    Time delay RCDs are typically used where two RCDs are installed in series and selective discrimination is required. Installation must be carried out by a qualified electrician.

    • Mount on a compatible DIN rail inside a suitable enclosure
    • Use as part of a coordinated upstream/downstream protection design
    • Apply the recommended terminal torque of 2.5Nm
    • Verify correct device coordination during design and commissioning