CATEGORIES

3-Pole Type A RCBO – 40A C Curve 30mA 10kA (WRT340C-030)

  • £75.85
  • 18th Ed. Compliant

    2-Year Warranty

    UK Stock

    Free Delivery £80+

    Secure Payments With

    Google Pay PayPal

    The WRT340C-030 is a 3-pole Type A RCBO providing combined residual current and overcurrent protection for three-phase circuits rated up to 40A. With a C curve tripping characteristic and 30mA sensitivity, it offers dependable protection against overload, short-circuit, and earth leakage faults in a compact 3-module DIN rail format. Type...

    The WRT340C-030 is a 3-pole Type A RCBO providing combined residual current and overcurrent protection for three-phase circuits rated up to 40A. With a C curve tripping characteristic and 30mA sensitivity, it offers dependable protection against overload, short-circuit, and earth leakage faults in a compact 3-module DIN rail format.

    Type A residual current protection enables detection of AC residual currents and pulsating DC components, making this RCBO suitable for modern installations containing electronic equipment. The C curve response allows for moderate inrush currents, typically associated with motors, pumps, HVAC equipment, and mixed-load commercial distribution boards.

    Installer note: Switched neutral operation disconnects L1, L2, L3, and N together, improving isolation safety and reducing time spent during insulation resistance testing.

    • 3-pole Type A RCBO with integrated overcurrent protection
    • 40A rated current with C curve characteristic
    • 30mA residual current sensitivity
    • 10kA short-circuit breaking capacity
    • Switched neutral for full disconnection of live conductors
    • Compact 3-module DIN rail design
    • Clear IN / OUT / LOAD terminal markings
    Part Code Rating Curve Residual Current
    WRT340C-030 40A C Curve 30mA
    WRT320C-030 20A C Curve 30mA
    WRT332B-030 32A B Curve 30mA
    WRT332C-030 32A C Curve 30mA
    WRT340B-030 40A B Curve 30mA
    WRT350C-030 50A C Curve 30mA

    The WRT340C-030 is well suited to three-phase circuits where Type A protection and tolerance for moderate inrush currents are required at higher operating currents.

    What applications suit a C curve RCBO?

    C curve RCBOs are commonly used on circuits with moderate inrush currents, such as motors, pumps, HVAC systems, and mixed commercial loads.

    Does this RCBO include a switched neutral?

    Yes. The neutral is switched, providing full disconnection of all live conductors.

    Is this suitable for three-phase commercial installations?

    Yes. It is designed for three-phase commercial, industrial, and advanced residential installations.

    What is the short-circuit breaking capacity?

    The WRT340C-030 has a rated breaking capacity of 10kA.

    Is this supplied pre-wired?

    No. This RCBO is supplied as a DIN-rail-mounted device and must be wired during installation.

    • Device Type: 3-Pole RCBO
    • Residual Current Type: Type A
    • Rated Current: 40A
    • Tripping Curve: C Curve
    • Residual Current Sensitivity: 30mA
    • Breaking Capacity: 10kA
    • Number of Modules: 3
    • Neutral: Switched
    • Mounting: DIN rail (EN 60715)
    • Rated Voltage: 230V AC
    • Frequency: 50/60Hz
    • Compliance: IEC / EN 61009-1

    This RCBO must be installed by a qualified electrician within a three-phase distribution board. Care should be taken to ensure correct termination of supply and load conductors.

    • Mount on a standard 35mm DIN rail
    • Observe IN / OUT / LOAD markings during installation
    • Do not connect incoming supply to load terminals
    • Switched neutral enables full isolation during testing
    • Confirm C curve suitability for motor or mixed-load circuits