32A 4 Pole 10kA MCB C Curve – WKC432C
The WKC432C is a 32A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral systems. With a C Curve trip profile,...
Your basket
Loading your basket…
Prices exclude VAT. VAT, shipping and discounts are calculated at checkout.
Shop circuit protection devices for domestic, commercial and specialist installations, including MCBs, RCDs, RCBOs and surge protection. Use the filters to narrow the range by device type, rating and application.
Device selection depends on the circuit design, load characteristics, prospective fault current, required residual-current response and the equipment manufacturer’s instructions.
Quick guide: MCBs provide overcurrent protection; RCDs respond to residual current; RCBOs combine both functions for individual circuits. RCD type, trip curve, current rating and breaking capacity must be selected for the installation.
The WKC432C is a 32A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral systems. With a C Curve trip profile,...
The WKC425C is a 25A 4 pole 10kA Miniature Circuit Breaker (MCB) designed to protect three-phase + neutral systems. With its C Curve trip...
The WKC420C is a 20A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral systems. With its C Curve trip characteristic,...
The WKC416C is a 16A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its C Curve trip characteristic,...
The WKC406C is a 6A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its C Curve trip characteristic,...
The WKC463B is a 63A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its B Curve trip characteristic,...
The WKC450B is a 50A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral systems. With a B Curve trip characteristic,...
The WKC440B is a 40A 4 pole 10kA Miniature Circuit Breaker (MCB) for three-phase + neutral circuits. With its B Curve trip characteristic, this...
The WKC432B is a 32A 4 pole 10kA Miniature Circuit Breaker (MCB) for three-phase + neutral protection. With its B Curve trip profile, this...
The WKC425B is a 25A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral circuits. With a B Curve trip profile,...
The WKC420B is a 20A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its B Curve trip characteristic,...
The WKC416B is a 16A 4 pole 10kA Miniature Circuit Breaker (MCB) designed to protect three-phase + neutral circuits. With its B Curve trip...
Start with the circuit design and connected equipment—not a device label in isolation. The protective device must suit the load, conductor capacity, earthing arrangement, prospective fault current and any residual-current characteristics identified by the equipment manufacturer. Installation and verification should be completed by a competent electrical professional to the applicable edition of BS 7671.
Miniature circuit breakers provide protection against overload and short-circuit current. Select the current rating, trip curve and breaking capacity from the installation design and load characteristics.
Residual current devices disconnect when the monitored current imbalance reaches their operating threshold. The correct type and sensitivity depend on the application and expected residual-current waveform.
RCBOs combine overcurrent and residual-current protection in one device. Per-circuit protection can improve fault discrimination and limit disruption elsewhere in the installation.
Surge ProtectionHigh Immunity RCBOsType B RCDsArc Fault DetectionElectrical Enclosures
Trade support: UK-stocked products, manufacturer-backed specifications and fast dispatch. Check each product page for standards, ratings, stock status and delivery details before ordering.