CATEGORIES

Circuit Protection – MCB, RCD & RCBO Breakers

Choose from our range of MCBs, RCDs, and RCBOs – all designed for safe, compliant, and reliable circuit protection under the 18th Edition. We also stock High Immunity RCBOs for EV/solar circuits and Type B RCDs for DC fault protection.

Read more

MCBs (Miniature Circuit Breakers) protect against overloads and short circuits, RCDs (Residual Current Devices) guard against earth leakage, and RCBOs combine both protections in a single device – now the preferred option for many UK domestic and commercial installs.

  • Type B, C & D breakers – suitable for different load types and fault conditions
  • Compact RCD enclosures – ideal for garages, outdoor feeds, and sub-circuits
  • Type A & Type B RCBOs – futureproof installs with advanced fault coverage
  • BS EN certified – tested and compliant with UK wiring regulations

All products are clearly labelled, warrantied for 2 years, and available with next-day UK delivery if ordered before 2pm. See our returns policy for hassle-free returns.

Showing 186 to 190 of 192 items
4 Pole B-Type RCD – WEV440B-030 (40A, 30mA)

power-and-data-uk

4 Pole B-Type RCD – WEV440B-030 (40A, 30mA)

£158.30

The WEV440B-030 is a 4 Pole Type B RCD (40A, 30mA) designed for circuits where smooth DC or high-frequency leakage currents may be present. Unlike Type A RCDs, it detects AC, pulsed DC, and smooth DC residual currents up to 1000 Hz, ensuring safe disconnection...

A Type Time Delay RCD – 63A 100mA, 2 Pole (WARTD263-100)

power-and-data-uk

A Type Time Delay RCD – 63A 100mA, 2 Pole (WARTD263-100)

£25.35

The WARTD263-100 A-Type 100mA Time Delay RCD is a 2 Pole S-Type device designed for upstream fault protection in dual-RCD or selective coordination setups. With its built-in delay, it ensures that downstream devices trip first, maintaining supply integrity across unaffected circuits. Ideal for EV charging...

A Type Time Delay RCD – 63A 100mA, 4 Pole (WARTD463-100)

power-and-data-uk

A Type Time Delay RCD – 63A 100mA, 4 Pole (WARTD463-100)

£30.25

The WARTD463-100 A-Type 100mA Time Delay RCD is a 4 Pole S-Type device rated at 63A. Its built-in time delay ensures upstream discrimination, allowing downstream RCDs to trip first and preventing unnecessary power loss. Ideal for three-phase distribution boards, EV charging hubs, and renewable installs...

4 Pole MCB 10kA C Curve 100A WKC4100C

power-and-data-uk

4 Pole MCB 10kA C Curve 100A WKC4100C

£30.67

The WCED WKC4100C is a 4 Pole 100A MCB with a C curve tripping characteristic and a 10kA breaking capacity. Designed for high-demand installations, it provides reliable protection against overloads and short-circuits while also serving as an isolator when required. Commonly used in EV charging...

5 Pole 100A Auto Resetting MCBs WARB5100C

power-and-data-uk

5 Pole 100A Auto Resetting MCBs WARB5100C

£44.05

The WCED WARB5100C is a 5 Pole 100A Auto Resetting MCB designed for advanced three-phase systems where neutral and earth monitoring is required. It combines overload, short-circuit, and voltage monitoring with automatic reset after under-voltage events – reducing downtime on critical installations. With integrated PME...

Understanding Circuit Protection

Every electrical installation in the UK relies on the right circuit protection to keep people and property safe. Under the 18th Edition Wiring Regulations, MCBs, RCDs, and RCBOs each play a critical role in managing faults and preventing serious damage or injury.

MCBs – Overload & Short Circuit Protection

Miniature Circuit Breakers (MCBs) automatically trip if a circuit draws more current than it can safely handle, or if a short circuit occurs. They are available in different trip curves (B, C, D) to match the type of load – from standard domestic circuits to high inrush motors and industrial equipment.

Installer favourite: 10kA MCBs for domestic and light commercial circuits.

RCDs – Earth Leakage Protection

Residual Current Devices (RCDs) are designed to protect people by disconnecting the supply if they detect current leaking to earth – a sign of electric shock risk or faulty equipment. They are mandatory on most UK final circuits and are typically rated at 30mA for personal protection.

Example product: 2-Pole A-Type 100mA Time Delay RCD, suited for submain and select commercial installs.

RCBOs – Combined Protection

Residual Current Breaker with Overcurrent (RCBO) combines the functions of an MCB and an RCD in a single unit. This gives each circuit its own dedicated protection, reducing nuisance tripping and aligning with modern best practice for new builds and upgrades.

Best-seller: A-Type RCBO – available in multiple ratings for modern domestic installs.

Key Buying Considerations

  • Type A or Type B devices – Type A is now standard, while Type B covers DC leakage common in EV chargers, heat pumps, and solar systems.
  • Trip curve selection – B-curve for domestic, C-curve for commercial, D-curve for industrial/high inrush loads.
  • Current rating – match the breaker to the cable size and expected load to avoid nuisance trips.
  • Single vs double pole – choose based on isolation requirements and application.

Why Buy From Power & Data UK?

All our circuit protection devices are BS EN certified, backed by a 2-year warranty, and supplied from our UK warehouse. We offer free next-day delivery on orders over £30, with Saturday delivery options available. If you need to return an item, see our returns policy.

Related Categories

Looking for more protection solutions? Explore our full ranges:

Common Questions

Do I need an RCBO or an RCD?
RCBOs are now widely preferred as they protect individual circuits and avoid losing power to the whole board when one circuit trips. RCDs are still common in older setups and for grouped circuits.

What’s the difference between Type A and Type AC RCDs?
Type A units detect both AC and pulsed DC leakage and are required for modern electronics, EV chargers, and heat pumps. Type AC is being phased out for most applications in the UK.

Can I mix MCBs, RCDs and RCBOs?
Yes – many consumer units are designed to house a combination. For new installs, RCBOs are usually recommended for maximum safety and flexibility.