16A 4 Pole 10kA MCB C Curve – WKC416C
The WKC416C is a 16A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its C Curve trip characteristic, it is suitable for inductive load circuits including motors, HVAC, and EV charger distribution boards in commercial three-phase systems, EV installations, and solar PV setups. With...
Read full descriptionAccepted payment methods
Description
The WKC416C is a 16A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its C Curve trip characteristic, it is suitable for inductive load circuits including motors, HVAC, and EV charger distribution boards in commercial three-phase systems, EV installations, and solar PV setups.
With a 10kA breaking capacity, the WKC416C provides overload and short-circuit protection while isolating all live conductors and the neutral. It is DIN-rail mounted, bi-directional, and tested to BS 7671 (18th Edition).
Installer Tip: Choose the 16A C Curve when protecting small to medium inductive loads such as HVAC fan motors, pumps, or commercial lighting with inrush currents.
Key Features
- 16A 4 Pole MCB – C Curve trip profile
- 10kA breaking capacity – reliable for commercial installs
- Four-pole isolation: L1, L2, L3 + Neutral
- Bi-directional feed: install top or bottom
- DIN-rail mountable: 18mm per module
- Complies with BS 7671 (18th Edition)
Compare WKC 4 Pole 10kA MCBs (C Curve)
| Model | Rating | Curve | Breaking Capacity |
|---|---|---|---|
| WKC410C | 10A | C Curve | 10kA |
| WKC416C (This Product) | 16A | C Curve | 10kA |
| WKC420C | 20A | C Curve | 10kA |
| WKC425C | 25A | C Curve | 10kA |
Technical specs
- Model: WKC416C
- Type: Miniature Circuit Breaker (MCB)
- Current Rating: 16A
- Curve: C Curve
- Poles: 4P (L1, L2, L3 + Neutral)
- Breaking Capacity: 10kA
- Mounting: 35mm DIN rail, 18mm width per pole
- Dimensions: Approx. 72mm (W) x 90mm (H) x 77mm (D)
- Standards: BS 7671 (18th Edition), IEC/EN 60898-1
- Brand: WCED
Installation notes
The WKC416C must be installed by a qualified electrician in accordance with BS 7671 regulations.
- DIN rail mounted (18mm per pole)
- Check system fault current ≤10kA
- Use for inductive or moderate inrush loads (C Curve)
- Tighten terminals to correct torque setting
- Ensure adequate space for 4P devices in the enclosure
FAQs
What applications suit the WKC416C?
It is best for small to medium inductive loads such as HVAC fans, pumps, and lighting circuits with higher inrush currents.
How does a C Curve differ from a B Curve?
C Curve breakers are designed to handle moderate inrush currents, unlike B Curve models which are for resistive loads only.
Is the WKC416C suitable for EV chargers?
Yes — the 16A C Curve is suited for EV charger sub-circuits where inrush currents are common, provided the system fault current ≤10kA.
What compliance standards does it meet?
It is manufactured to BS 7671 (18th Edition) and IEC/EN 60898-1 standards.