High Immunity RCBO – 20A B Curve, Type A, 30mA
£23.50 ex. VAT
£28.20 inc. VAT
Your basket
Loading your basket…
Prices exclude VAT. VAT, shipping and discounts are calculated at checkout.
The WER40B-030 combines 40A B-curve overcurrent protection and 30mA Type A residual-current protection in one high-immunity RCBO, with switched live and neutral and separate handles to help identify the type of trip. Combined protection with useful fault indication For circuits specified with this rating and curve, the WER40B-030 brings overload,...
Read full descriptionAccepted payment methods
The WER40B-030 combines 40A B-curve overcurrent protection and 30mA Type A residual-current protection in one high-immunity RCBO, with switched live and neutral and separate handles to help identify the type of trip.
For circuits specified with this rating and curve, the WER40B-030 brings overload, short-circuit and residual-current protection into a two-module device. Its Type A characteristic detects AC and pulsating DC residual currents.
View the Whitecliffe WER technical datasheet (PDF) for the twin-handle explanation, electrical ratings and installation data.
Start with the specified current rating, curve, residual-current type and board compatibility. A change of curve or product range needs to match the circuit design.
| Product | Configuration | When to consider it |
|---|---|---|
| WER40B-030 — this product | 40A B curve; Type A, 30mA; two modules; 10kA | Your specification calls for the B-curve WER device with switched live and neutral and separate MCB/RCD handles. |
| WER40C-030 | 40A C curve; Type A, 30mA; two modules; 10kA | Your load characteristics and circuit design call for C curve. The current rating remains 40A. |
| WRB140B-030 mini RCBO | 40A B curve; Type A, 30mA; single-module WRB range | You are selecting a single-module format. Check the WRB ratings, dimensions and assembly compatibility before choosing it. |
B curve and Type B mean different things This product is a B-curve Type A RCBO. Where equipment requires Type B residual-current protection, choose from the appropriate Type B range instead. For EV, solar or heat-pump projects, match the complete protection arrangement to the equipment instructions.
Browse high-immunity RCBOs for other current ratings. Once WER40B-030 matches your specification, select the required quantity above to order.
Need a product check? Contact Power & Data UK with the RCBO code, board model and required rating so the team can check the relevant product information.
| Specification | Details |
|---|---|
| Product code | WER40B-030 |
| Device | High-immunity Type A RCBO |
| Rated current / trip curve | 40A / B curve |
| Rated sensitivity | 30mA |
| Rated voltage / frequency | 230/240V AC / 50/60Hz |
| Breaking capacity | 10kA |
| Poles | 2; switched live and neutral |
| Power flow | Bidirectional; follow the supplied connection instructions |
| Module width | 2 modules |
| Standards stated in WER datasheet | EN 61009-1 and IEC 61009-1 |
Fault indication: Separate MCB and RCD handles; see the manufacturer datasheet for the indication details.
A qualified electrician should select and install this RCBO using the instructions supplied with the exact model and the applicable BS 7671 requirements.
Whitecliffe identifies separate MCB and RCD handles. Their trip positions help an electrician distinguish an overload or short-circuit event from a residual-current event. See the manufacturer's datasheet for the indication details and follow its instructions when investigating faults.
Both are 40A, 30mA Type A WER RCBOs. The difference is the overcurrent trip curve. Compare the C-curve WER40C-030 where the equipment and circuit design require that characteristic.
No. B curve describes the overcurrent tripping characteristic. This device has Type A residual-current protection for AC and pulsating DC waveforms; it is not a Type B residual-current device.
Yes. Whitecliffe's WER datasheet specifies switched live and neutral and a two-pole device.
WER is a two-module range. Confirm the board, busbar and physical clearances for the exact assembly. A single-module RCBO from another range is a separate product choice, not an automatic replacement.
Whitecliffe identifies the WER range as bidirectional. Suitability still depends on the equipment instructions, circuit design and any additional DC residual-current or earthing protection required. Follow the supplied connection instructions.