CATEGORIES

10kA MCBs for High Fault-Level Circuits

10kA MCBs are miniature circuit breakers designed for circuits with higher prospective fault currents. They offer a higher breaking capacity than standard domestic breakers, making them suitable for commercial boards, industrial panels, three-phase supplies and installations close to the transformer where fault levels are elevated.

Read more

These MCBs provide reliable overcurrent and short-circuit protection with 10,000 A breaking capacity, ensuring safe operation in environments where higher fault energy is expected. They are available in a full range of current ratings and tripping curves, allowing installers to select the correct device based on circuit behaviour and load type.

  • 10kA breaking capacity for high fault-level environments
  • Available in B and C curves for domestic, commercial and industrial applications
  • Wide rating range including 6A, 10A, 16A, 32A and higher
  • Single-module DIN-rail format for easy installation
  • Stable disconnection under heavy short-circuit conditions

10kA MCBs are routinely specified in commercial distribution boards, three-phase supply setups, and circuits located near the incoming supply where prospective fault currents exceed the capabilities of standard 6kA breakers.

Showing 16 to 20 of 67 items
WKC 3 Pole 10kA MCB – 16A B Curve (WKC316B)

power-and-data-uk

WKC 3 Pole 10kA MCB – 16A B Curve (WKC316B)

£21.30

The WKC316B 3 Pole 10kA MCB is a 16A B Curve breaker built to protect three-phase circuits from overload and short-circuit faults. With a 10kA breaking capacity and full compliance with BS 7671 (18th Edition), it’s ideal for small commercial loads, EV charging boards, and...

WKC 3 Pole 10kA MCB – 10A C Curve (WKC310C)

power-and-data-uk

WKC 3 Pole 10kA MCB – 10A C Curve (WKC310C)

£21.30

The WKC310C 3 Pole 10kA MCB is a 10A C Curve breaker designed to protect three-phase circuits from short-circuit and overload faults. Rated at 10kA breaking capacity and BS 7671 (18th Edition) compliant, it’s widely used in industrial boards, EV chargers, and solar PV installs....

WKC 3 Pole 10kA MCB – 10A B Curve (WKC310B)

power-and-data-uk

WKC 3 Pole 10kA MCB – 10A B Curve (WKC310B)

£21.30

The WKC310B 3 Pole 10kA MCB is a 10A B Curve breaker designed to protect three-phase circuits against overloads and short-circuit faults. With a 10kA breaking capacity, it delivers safe disconnection in commercial and industrial boards, EV charging systems, and solar PV installations. Compact and...

6A 4 Pole 10kA MCB D Curve – WKC406D

power-and-data-uk

6A 4 Pole 10kA MCB D Curve – WKC406D

£14.16

The WKC406D is a 6A 4 pole 10kA Miniature Circuit Breaker (MCB) built for three-phase + neutral protection. With its D Curve trip characteristic, it is designed for heavy inrush load circuits such as transformers, welders, large motors, and industrial machinery in commercial boards, industrial...

6A 4 Pole 10kA MCB C Curve – WKC406C

power-and-data-uk

6A 4 Pole 10kA MCB C Curve – WKC406C

£14.16

The WKC406C is a 6A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With its C Curve trip characteristic, it is suited to inductive load circuits such as motors, HVAC, and commercial distribution boards in three-phase systems, EV charging units,...

What Makes a 10kA MCB Different?

A 10kA MCB is engineered to interrupt short-circuits up to 10,000 amps without catastrophic failure. This higher breaking capacity ensures safety and compliance in installations where the calculated PFC (Prospective Fault Current) exceeds domestic levels.

Where 10kA MCBs Are Used

  • Commercial and industrial distribution boards
  • Three-phase supplies with higher fault levels
  • Installations close to the service head or transformer
  • Workshops, plant rooms and machinery feeds
  • Retrofits where standard 6kA devices are insufficient

B Curve vs C Curve 10kA MCBs

B Curve: Trips between 3–5 × rated current. Suitable for lighting circuits and resistive loads.

C Curve: Trips between 5–10 × rated current. Ideal for motor-driven or surge-prone circuits.

When to Specify 10kA Breaking Capacity

A 10kA MCB should be used whenever fault calculations or the measured PFC approach the limit of a 6kA device. Commercial boards, workshops and three-phase panels often require this rating as standard.

  • Higher fault-current environment
  • Near incomer or transformer
  • Industrial machinery circuits
  • Large commercial properties

Compliance & Standards

All 10kA MCBs in this category are designed to comply with BS EN 60898 and meet the performance and safety expectations of the 18th Edition Wiring Regulations. They are suitable for new installations and replacement upgrades requiring higher fault protection.

Installer Benefits

10kA MCBs provide confidence and compliance in higher-risk environments. Their robust construction, predictable tripping characteristics and wide rating availability make them a dependable choice for professional electricians working on commercial, industrial and high-demand domestic installations.