10kA MCBs for High Fault-Level Circuits

10kA MCBs are miniature circuit breakers designed for circuits with higher prospective fault currents. They offer a higher breaking capacity than standard domestic breakers, making them suitable for commercial boards, industrial panels, three-phase supplies and installations close to the transformer where fault levels are elevated.

Read more

These MCBs provide reliable overcurrent and short-circuit protection with 10,000 A breaking capacity, ensuring safe operation in environments where higher fault energy is expected. They are available in a full range of current ratings and tripping curves, allowing installers to select the correct device based on circuit behaviour and load type.

  • 10kA breaking capacity for high fault-level environments
  • Available in B and C curves for domestic, commercial and industrial applications
  • Wide rating range including 6A, 10A, 16A, 32A and higher
  • Single-module DIN-rail format for easy installation
  • Stable disconnection under heavy short-circuit conditions

10kA MCBs are routinely specified in commercial distribution boards, three-phase supply setups, and circuits located near the incoming supply where prospective fault currents exceed the capabilities of standard 6kA breakers.

Showing 31 to 35 of 67 items
4 pole 10kA MCB's 10A B Curve WKC410B

power-and-data-uk

4 pole 10kA MCB's 10A B Curve WKC410B

£14.16

The WKC410B is a 10A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral circuits. With a B Curve trip characteristic, it is suited for resistive loads such as lighting and socket circuits across three-phase distribution boards, EV installations, and solar PV...

32A 4 Pole 10kA MCB D Curve – WKC432D

power-and-data-uk

32A 4 Pole 10kA MCB D Curve – WKC432D

£14.16

The WKC432D is a 32A 4 pole 10kA Miniature Circuit Breaker (MCB) built for three-phase + neutral protection. With a D Curve trip profile, it is designed for very high inrush load circuits such as welders, transformers, heavy-duty motors, compressors, and industrial machinery. It is...

Sold Out
32A 4 Pole 10kA MCB C Curve – WKC432C

power-and-data-uk

32A 4 Pole 10kA MCB C Curve – WKC432C

£14.16

The WKC432C is a 32A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral systems. With a C Curve trip profile, it is suited to inductive load applications such as motors, pumps, HVAC units, EV charger circuits, and commercial lighting in distribution...

32A 4 Pole 10kA MCB B Curve – WKC432B

power-and-data-uk

32A 4 Pole 10kA MCB B Curve – WKC432B

£14.16

The WKC432B is a 32A 4 pole 10kA Miniature Circuit Breaker (MCB) for three-phase + neutral protection. With its B Curve trip profile, this breaker is suited for resistive load circuits such as general socket banks, lighting, and small sub-distribution panels across commercial three-phase boards,...

25A 4 Pole 10kA MCB D Curve – WKC425D

power-and-data-uk

25A 4 Pole 10kA MCB D Curve – WKC425D

£14.16

The WKC425D is a 25A 4 pole 10kA Miniature Circuit Breaker (MCB) designed for three-phase + neutral protection. With a D Curve trip characteristic, this breaker is engineered for very high inrush load circuits such as welders, transformers, heavy industrial motors, and machinery. It is...

What Makes a 10kA MCB Different?

A 10kA MCB is engineered to interrupt short-circuits up to 10,000 amps without catastrophic failure. This higher breaking capacity ensures safety and compliance in installations where the calculated PFC (Prospective Fault Current) exceeds domestic levels.

Where 10kA MCBs Are Used

  • Commercial and industrial distribution boards
  • Three-phase supplies with higher fault levels
  • Installations close to the service head or transformer
  • Workshops, plant rooms and machinery feeds
  • Retrofits where standard 6kA devices are insufficient

B Curve vs C Curve 10kA MCBs

B Curve: Trips between 3–5 × rated current. Suitable for lighting circuits and resistive loads.

C Curve: Trips between 5–10 × rated current. Ideal for motor-driven or surge-prone circuits.

When to Specify 10kA Breaking Capacity

A 10kA MCB should be used whenever fault calculations or the measured PFC approach the limit of a 6kA device. Commercial boards, workshops and three-phase panels often require this rating as standard.

  • Higher fault-current environment
  • Near incomer or transformer
  • Industrial machinery circuits
  • Large commercial properties

Compliance & Standards

All 10kA MCBs in this category are designed to comply with BS EN 60898 and meet the performance and safety expectations of the 18th Edition Wiring Regulations. They are suitable for new installations and replacement upgrades requiring higher fault protection.

Installer Benefits

10kA MCBs provide confidence and compliance in higher-risk environments. Their robust construction, predictable tripping characteristics and wide rating availability make them a dependable choice for professional electricians working on commercial, industrial and high-demand domestic installations.