8 Way Heat Pump Consumer Unit with Type B HP RCD (WME08/HP40C)
18th Ed. Compliant
2-Year Warranty
UK Stock
Free Delivery £80+
Secure Payments With
Pre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping. The WME08/HP40C 8 Way Heat Pump Consumer Unit is a dedicated protection board for inverter-driven heat pump systems. It is supplied in a compact metal enclosure with Type B HP RCD protection, Type...
Pre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping.
The WME08/HP40C 8 Way Heat Pump Consumer Unit is a dedicated protection board for inverter-driven heat pump systems. It is supplied in a compact metal enclosure with Type B HP RCD protection, Type 2 surge protection and 16A C Curve MCBs.
Installer Note: Whitecliffe’s heat pump range uses Type B HP RCD protection for inverter-driven heat pump systems where smooth DC and high-frequency residual currents may be present. Always confirm the final protective device requirements against the heat pump manufacturer’s specification.
Why choose this 8 way heat pump consumer unit?
The WME08/HP40C is the compact 8 way option in the Whitecliffe heat pump consumer unit range. It suits installs where the heat pump circuit needs dedicated Type B HP RCD protection, surge protection and a smaller enclosure footprint. For larger layouts, see the 12 way version.
Key Features
- Factory-fitted devices: 40A Type B RCD, 40A Type C 10kA MCB, 2P Type 2 SPD
- Compact size: 232 × 240 × 112mm enclosure
- Expansion ready: spare DIN space for future RCBOs or MCBs
- Compliant: BS 7671:2018+A2:2022 renewable regulations
- Durable build: white powder-coated steel, surface mount with knockouts
Type B HP RCD protection for heat pumps
Modern inverter-driven heat pumps can produce smooth DC and high-frequency residual currents. Whitecliffe’s Type B HP RCDs are designed for this type of application, helping provide the right protection where standard RCD types may not be suitable.
This is the main reason the WME08/HP40C is positioned as a dedicated heat pump consumer unit rather than a standard small distribution board.
Variant Comparison
| Variant | Configuration | Best For |
|---|---|---|
| WME08/HP40C (8-Way – This Product) | 8-way board with 40A Type B HP RCD, 16A C-curve MCBs and Type 2 SPD 232 × 240 × 112mm enclosure |
Standard dedicated heat pump protection in a compact 8-way format |
| WME08/HPR40C (8-Way RCBO Variant) | 8-way board with 40A Type B HP RCD, 1 x 16A C-curve MCB, 2 x 16A RCBOs and Type 2 SPD 232 × 240 × 112mm enclosure |
Installations needing extra outgoing circuit protection within the same compact enclosure |
| WME12/HP40C (12-Way) | 12-way board with 40A Type B HP RCD, 16A C-curve MCBs and Type 2 SPD 304 × 240 × 112mm enclosure |
Larger installs or where spare ways are needed for future expansion |
Is this board compliant for heat pump installs under the 18th Edition?
Yes. It includes a Type B RCD and a Type 2 SPD, both required for inverter-driven loads such as heat pumps. For standalone installs, see our Heat Pump RCD.
What’s the difference between the 8-way and 12-way versions?
The devices supplied are the same. The 12-way simply provides more DIN space for adding future RCBOs or MCBs.
Can I add RCBOs to this board?
Yes. Spare DIN ways are included for adding outgoing protection devices. For nuisance-trip resistance, see our High Immunity RCBOs.
How quickly can this be delivered?
Each unit is built to order and dispatched within 3 working days. For in-stock options, see our 6 Way Consumer Units.
| Product Code | WME08/HP40C |
| Product Type | Heat Pump Consumer Unit |
| Enclosure Size | 8 Module |
| Dimensions | 232 x 240 x 112mm |
| RCD | Type B HP RCD |
| MCBs | 16A C Curve MCBs |
| SPD | Type 2 Surge Protection Device |
| Enclosure Material | Metal |
This board is supplied pre-wired and must be installed by a qualified electrician. It simplifies compliant protection for heat pump circuits requiring Type B RCD and SPD integration.
- Mount securely on a dry, internal surface using standard fixings
- Use rear or side knockouts for incoming and outgoing cables
- Ensure correct earthing and SPD bonding as per BS 7671
- Do not modify pre-wiring – contact us for custom builds if needed