10A 2 Pole 10kA MCB – D Curve (WKC210D)
18th Ed. Compliant
2-Year Warranty
UK Stock
Free Delivery £30+
Secure Payments With


The WKC210D is a 10 A 2 Pole 10 kA Miniature Circuit Breaker (MCB) designed for protecting circuits with high inrush or inductive loads. The D-curve tripping profile allows up to 20 × rated current during start-up, making it ideal for compressors, transformers, and motor control panels. Its dual-pole isolation...
The WKC210D is a 10 A 2 Pole 10 kA Miniature Circuit Breaker (MCB) designed for protecting circuits with high inrush or inductive loads. The D-curve tripping profile allows up to 20 × rated current during start-up, making it ideal for compressors, transformers, and motor control panels.
Its dual-pole isolation disconnects both live conductors simultaneously for enhanced safety and compliance with BS EN 60898-1. The 36 mm compact body fits standard 35 mm DIN-rails in consumer units, industrial enclosures, and commercial boards.
Installer Tip: Choose a D-curve MCB when protecting motors or transformers that draw large start-up currents. If the equipment has lower surge demand, a C-curve version is sufficient.
Key Features
- 10 A rated – suitable for compressors, control gear, and motors
- 10 kA breaking capacity – safe for industrial fault levels
- 2-pole isolation – disconnects both live conductors together
- D-curve tripping – tolerates high inrush (10–20× rated current)
- Bi-directional terminals – line or load feed either end
- 36 mm width – compact DIN-rail fit
- Tested to IEC/EN 60898-1 for 18th Edition compliance
Compare 2 Pole 10 kA MCB Variants
Model | Rating | Curve |
---|---|---|
WKC210B | 10 A | B Curve |
WKC210C | 10 A | C Curve |
WKC210D (This Product) | 10 A | D Curve |
When is a D-curve MCB recommended?
Use for inductive loads with high startup current – such as compressors, motors, or transformers.
Does it disconnect both conductors?
Yes – the 2-pole design disconnects both live lines simultaneously for safe isolation.
Can it be used in industrial control panels?
Yes – commonly used in control and plant equipment panels for motor protection.
Is it 18th Edition compliant?
Yes – fully tested to BS EN 60898-1 and suitable for 18th Edition installations.
- Model: WKC210D
- Poles: 2
- Rated Current: 10 A
- Curve Type: D
- Breaking Capacity: 10 kA
- Operating Voltage: 230/400 V AC
- Mounting: 35 mm DIN rail (EN 60715)
- Width: 36 mm (2 modules)
- Standard: IEC/EN 60898-1
- Applications: Compressors, transformers, motor control gear
To be installed by a qualified electrician under BS 7671. Confirm that the connected load justifies a D-curve characteristic before energising.
- Mount on 35 mm DIN rail (EN 60715)
- Torque terminals to 2.0–2.5 Nm
- Check insulation resistance and polarity before connection
- Label and record protected circuits within the distribution schedule