10A 2 Pole 10kA MCB – C Curve (WKC210C)
18th Ed. Compliant
2-Year Warranty
UK Stock
Free Delivery £30+
Secure Payments With


The WKC210C is a 10 A 2 Pole 10 kA Miniature Circuit Breaker (MCB) built for circuits with moderate inrush currents such as fans, pumps, control relays, and LED lighting drivers. Its C-curve tripping characteristic provides a short delay on energisation, reducing nuisance tripping without compromising fault protection. Each breaker...
The WKC210C is a 10 A 2 Pole 10 kA Miniature Circuit Breaker (MCB) built for circuits with moderate inrush currents such as fans, pumps, control relays, and LED lighting drivers. Its C-curve tripping characteristic provides a short delay on energisation, reducing nuisance tripping without compromising fault protection.
Each breaker isolates both live conductors simultaneously for complete safety and compliance with BS EN 60898-1. Compact 36 mm form allows easy installation on any 35 mm DIN rail — ideal for consumer units, enclosures, and commercial boards.
Installer Tip: Use a C-curve MCB where inrush current exceeds the B-curve threshold — common in control panels, fan systems, or where multiple LED fittings are switched together. For low inrush or purely resistive loads, see the B-curve version.
Key Features
- 10 A rated – suited to HVAC control, fans, and lighting drivers
- 10 kA breaking capacity – handles high fault levels safely
- 2-pole design – isolates both live conductors simultaneously
- C-curve tripping – tolerates moderate inrush on start-up
- Bi-directional terminals – connect supply or load either end
- Compact 36 mm width – fits standard DIN-rail consumer units
- Complies with IEC/EN 60898-1 and 18th Edition Regs
Compare 2 Pole 10 kA MCB Variants
Model | Rating | Curve |
---|---|---|
WKC210B | 10 A | B Curve |
WKC210C (This Product) | 10 A | C Curve |
WKC210D | 10 A | D Curve |
When should I use a C-curve instead of a B-curve MCB?
Use a C-curve when the circuit includes devices with moderate inrush currents, such as LED lighting drivers, motors, or transformers.
Does this breaker isolate both conductors?
Yes – the 2-pole design disconnects both live conductors simultaneously for safety and compliance.
Is this suitable for lighting panels?
Yes – ideal for grouped LED or control lighting circuits where B-curve devices may trip too early.
Is it compliant with 18th Edition standards?
Yes – tested to BS EN 60898-1 and compliant with the 18th Edition Wiring Regulations.
- Model: WKC210C
- Poles: 2
- Rated Current: 10 A
- Curve Type: C
- Breaking Capacity: 10 kA
- Operating Voltage: 230/400 V AC
- Mounting: 35 mm DIN rail (EN 60715)
- Width: 36 mm (2 modules)
- Standard: IEC/EN 60898-1
- Applications: HVAC control, fans, lighting drivers, automation circuits
Install by a qualified electrician in line with BS 7671. Confirm circuit design, expected inrush current, and correct curve selection before fitting.
- Mount securely on 35 mm DIN rail (EN 60715)
- Torque terminals to 2.0–2.5 Nm
- Verify insulation resistance and polarity before energising
- Label and record circuit data in distribution schedule