Heat Pump RCD -B Type 2 Pole - WHP240-030

  • £125.00
  • The WHP240-030 is a compact Type B RCD specifically designed for heat pump systems - including Vaillant installations where full DC fault protection is required. Unlike Type A or Type AC RCDs, this 2 pole device is engineered to detect smooth DC leakage currents and operate reliably at high switching...

    The WHP240-030 is a compact Type B RCD specifically designed for heat pump systems - including Vaillant installations where full DC fault protection is required. Unlike Type A or Type AC RCDs, this 2 pole device is engineered to detect smooth DC leakage currents and operate reliably at high switching frequencies above 20kHz.

    Fully compliant with the 18th Edition and BS 7671 wiring regulations, it’s an essential safety component for inverter-driven heating systems and renewable installs. With a space-saving 2-module width, it’s easy to integrate into standard consumer units using conventional busbars.

    • Type B RCD: Detects smooth DC leakage up to 150mA
    • Frequency Tested: Verified to trip above 20kHz switching noise
    • 2 pole, 2 module design for compact installs
    • Required for Vaillant heat pump compliance
    • BS 7671 & 18th Edition compliant for domestic and commercial use

    Tags: B Type RCD

    Why is a Type B RCD needed for heat pump systems?

    Heat pumps and inverter-driven systems can generate smooth DC leakage currents. Type B RCDs are the only devices capable of detecting and disconnecting in those fault conditions - especially for compliance with manufacturers like Vaillant.

    Can I use a Type A RCD instead?

    No - Type A RCDs do not detect smooth DC faults. This could leave the system unprotected in the event of leakage through the inverter or drive circuit.

    Does this work with standard consumer units?

    Yes - the 2-module width allows installation on a standard DIN rail using a conventional busbar setup.

    What’s the tripping threshold?

    This RCD trips at a minimum of 150mA leakage for frequencies above 1kHz, making it suitable for high-frequency switching loads like heat pumps.

    Is this compliant with UK regulations?

    Yes - it meets BS EN 61008-1 and is suitable for 18th Edition Amendment 2 compliant installs.

    • SKU: WHP240-030
    • Device Type: Type B RCD
    • Modules: 2 module width
    • Poles: 2 Pole
    • Residual Current Rating: 30mA
    • Trip Sensitivity: ≥150mA for frequencies ≥1kHz
    • Frequency Detection: Tested up to and beyond 20kHz
    • Mounting: DIN rail compatible
    • Conformity: BS EN 61008-1, BS 7671

    Install this RCD in heat pump or inverter-driven systems where smooth DC fault protection is required. Ensure it’s fitted by a qualified electrician and matched to the system’s leakage profile and frequency range.

    • Mount directly onto DIN rail in consumer unit or control enclosure
    • Ensure correct orientation and secure terminal tightening
    • Use standard busbar configuration for fast fit-out
    • Test using a Type B RCD tester if available