6A 2 Pole 10kA MCB – D Curve (WKC206D)

  • £7.49
  • 18th Ed. Compliant

    2-Year Warranty

    UK Stock

    Free Delivery £30+

    Secure Payments With

    Google Pay PayPal

    The WKC206D is a 6 A 2 Pole 10 kA Miniature Circuit Breaker (MCB) engineered for circuits with high inductive or transformer inrush current. Its D-curve tripping profile allows 10–20× rated current on energisation, providing reliable protection for motors, coils, transformers, and control gear without nuisance tripping. With dual-pole isolation,...

    The WKC206D is a 6 A 2 Pole 10 kA Miniature Circuit Breaker (MCB) engineered for circuits with high inductive or transformer inrush current. Its D-curve tripping profile allows 10–20× rated current on energisation, providing reliable protection for motors, coils, transformers, and control gear without nuisance tripping.

    With dual-pole isolation, both live conductors disconnect simultaneously for safe maintenance and full compliance with BS EN 60898-1. Compact 36 mm body fits all 35 mm DIN-rail enclosures including consumer units, industrial enclosures, and three-phase panels.

    Installer Tip: Use a D-curve when protecting circuits with high start-up surge – for example, motors, transformers or inductive control gear. For lighting or low-inrush loads, see the C-curve model.

    Key Features

    • 6 A rated – ideal for transformers, motors, and control gear
    • 10 kA breaking capacity – safe for industrial fault levels
    • 2-pole isolation – disconnects both live conductors simultaneously
    • D-curve tripping – tolerates 10–20× inrush current on startup
    • Bi-directional terminals – connect from top or bottom feed
    • 36 mm (2-module) width for compact DIN-rail mount
    • Certified to IEC/EN 60898-1 and the 18th Edition Wiring Regulations

    Compare 2 Pole 10 kA MCB Variants

    Model Rating Curve
    WKC206B 6 A B Curve
    WKC206C 6 A C Curve
    WKC206D (This Product) 6 A D Curve

    When is a D-curve MCB required?

    D-curve breakers are used for motors, transformers or other high inrush equipment that might trip B or C curves on startup.

    Does it disconnect both live conductors?

    Yes – 2-pole isolation cuts both lines simultaneously for safe maintenance.

    Can it be used in industrial control panels?

    Yes – ideal for panels with coils, contactors, or transformers drawing brief surge currents.

    Is it 18th Edition compliant?

    Yes – tested to BS EN 60898-1 and fully compliant with current wiring standards.

    • Model: WKC206D
    • Poles: 2
    • Rated Current: 6 A
    • Curve Type: D
    • Breaking Capacity: 10 kA
    • Operating Voltage: 230/400 V AC
    • Mounting: 35 mm DIN rail (EN 60715)
    • Width: 36 mm (2 modules)
    • Standard: IEC/EN 60898-1
    • Applications: Transformers, motors, contactors, industrial control gear

    Install by a qualified electrician under BS 7671. Confirm that connected equipment requires D-curve characteristics before energising.

    • Mount securely on 35 mm DIN rail (EN 60715)
    • Torque terminals to 2.0–2.5 Nm
    • Check insulation resistance and polarity before connection
    • Record protected circuit on distribution schedule