32A 2 Pole 10kA MCB – D Curve (WKC232D)
18th Ed. Compliant
2-Year Warranty
UK Stock
Free Delivery £30+
Secure Payments With


The WKC232D is a 32 A 2 Pole 10 kA Miniature Circuit Breaker (MCB) built for protecting motor circuits, compressors, and feeder supplies with high start-up current. Its D-curve tripping profile tolerates 10–20× rated current at energisation, ensuring dependable operation for industrial and commercial inductive loads. Featuring dual-pole isolation, both...
The WKC232D is a 32 A 2 Pole 10 kA Miniature Circuit Breaker (MCB) built for protecting motor circuits, compressors, and feeder supplies with high start-up current. Its D-curve tripping profile tolerates 10–20× rated current at energisation, ensuring dependable operation for industrial and commercial inductive loads.
Featuring dual-pole isolation, both live conductors disconnect simultaneously for safe maintenance and compliance with BS EN 60898-1. Compact 36 mm housing fits standard 35 mm DIN rails used across industrial boards, distribution panels, and consumer units.
Installer Tip: The 32 A D-curve breaker is ideal for motor feeds, compressor lines, and control circuits where B or C curves may trip unnecessarily. For lower surge applications, opt for the C-curve version.
Key Features
- 32 A rated – ideal for feeder circuits, motor drives, and compressors
- 10 kA breaking capacity – suitable for commercial and industrial fault levels
- 2-pole isolation – safely disconnects both live conductors
- D-curve tripping – handles high inrush up to 20× rated current
- Bi-directional terminals – allows flexible top or bottom feed
- 36 mm (2-module) compact DIN-rail design
- Tested to IEC/EN 60898-1 and compliant with the 18th Edition Wiring Regulations
Compare 2 Pole 10 kA MCB Variants
Model | Rating | Curve |
---|---|---|
WKC232B | 32 A | B Curve |
WKC232C | 32 A | C Curve |
WKC232D (This Product) | 32 A | D Curve |
When should a 32 A D-curve MCB be used?
Use for motor or compressor circuits with high inrush currents where B or C curves would trip too easily.
Does it disconnect both live conductors?
Yes – dual-pole isolation disconnects both lines simultaneously for full safety compliance.
Can it be used for industrial feeders?
Yes – suitable for control panels, feeder supplies, and heavy-duty circuits in commercial setups.
Is it BS EN 60898-1 compliant?
Yes – fully certified to BS EN 60898-1 and suitable for 18th Edition installations.
- Model: WKC232D
- Poles: 2
- Rated Current: 32 A
- Curve Type: D
- Breaking Capacity: 10 kA
- Operating Voltage: 230/400 V AC
- Mounting: 35 mm DIN rail (EN 60715)
- Width: 36 mm (2 modules)
- Standard: IEC/EN 60898-1
- Applications: Motor circuits, compressors, feeders, industrial plant
Must be installed by a qualified electrician under BS 7671. Confirm that the connected load requires D-curve protection and verify cable sizing before energising.
- Mount on 35 mm DIN rail (EN 60715)
- Torque terminals to 2.0–2.5 Nm
- Test insulation and polarity prior to connection
- Clearly label all protected circuits within the board schedule