The WPGU04/620 is a factory-assembled IP65 plastic garage consumer unit featuring a 63 A 30 mA Type A RCD incomer and two B Curve MCBs rated at 6 A and 20 A. Designed for powering outbuildings, garages, and workshops, it offers safe and convenient circuit protection in a compact, weatherproof...
The WPGU04/620 is a factory-assembled IP65 plastic garage consumer unit featuring a 63 A 30 mA Type A RCD incomer and two B Curve MCBs rated at 6 A and 20 A. Designed for powering outbuildings, garages, and workshops, it offers safe and convenient circuit protection in a compact, weatherproof enclosure.
Installer Tip: This configuration is ideal for lighting (6 A) and socket or moderate load circuits (20 A). Use it as a sub-board for garden offices, sheds, or garage tools where an RCD incomer is required for additional protection under BS 7671 Reg 411.3.3.
- 63 A Type A RCD incomer – AC & pulsating DC fault protection
- 6 A + 20 A B Curve MCBs pre-fitted for lighting and socket loads
- IP65-rated enclosure – suitable for sheltered outdoor installs
- Earth & neutral bars included and internally pre-wired
- Compact design: 205 mm (H) × 140 mm (W) × 95 mm (D)
- Compliant with BS EN 61439-3 and BS 7671 Amendment 2
| Model | Incomer | MCB Configuration | Ingress Rating | Common Use |
|---|---|---|---|---|
| WPGU04/616 | 63 A Type A RCD | 6 A + 16 A | IP65 | Lighting + light sockets |
| WPGU04/620 | 63 A Type A RCD | 6 A + 20 A | IP65 | Lighting + medium loads |
| WPGU04/632 | 63 A Type A RCD | 6 A + 32 A | IP65 | Lighting + high-power tools |
This weatherproof garage unit provides an all-in-one, regulation-compliant solution for extending safe power to external or detached buildings. Pre-wired and tested for quick, trouble-free installation.
Is this suitable for outdoor workshops?
Yes – the IP65-rated housing protects against dust and water jets. It’s ideal for garden buildings, garages, and light commercial setups when properly sealed with cable glands.
Does this include both circuits?
Yes – one 6 A circuit for lighting and one 20 A circuit for socket or power tools are pre-fitted and protected by a 63 A Type A RCD incomer.
What’s the difference between this and the 32 A model?
The 32 A version supports heavier equipment like heaters or EV chargers.
Does it require a separate isolator?
No – the built-in RCD acts as the main incomer and isolation device, satisfying BS 7671 isolation requirements.
Can this be installed directly from the meter?
Yes – when used as a small sub-main unit, provided the supply is suitably fused and sized. For higher-rated incomers, see our fused switch range.
- Model: WPGU04/620
- Incomer: 63 A / 30 mA Type A RCD
- MCBs: 6 A + 20 A, B Curve
- Usable Ways: 2
- Enclosure: IP65 weatherproof plastic housing
- Dimensions (H × W × D): 205 × 140 × 95 mm
- Earth & Neutral Bars: Included (pre-installed)
- Voltage Rating: 230 V AC / 50 Hz
- Compliance: BS EN 61439-3 / BS EN 61008-1 / BS 7671:2018+A2:2022
Delivered pre-wired with fitted RCD and MCBs. Designed for indoor or sheltered outdoor installation. Ensure all gland seals are tightened correctly to maintain IP65 integrity and perform standard RCD testing after energising.
- Mount vertically with the cover closed
- Use IP-rated glands for external cables
- Confirm cable sizes and load currents before connection
- Test RCD trip at ½ IΔn, IΔn, and 5 × IΔn values
- Label circuits clearly for lighting and sockets