CATEGORIES

MCBs – Miniature Circuit Breakers

Miniature Circuit Breakers (MCBs) protect against overloads and short circuits, ensuring circuits disconnect safely under fault conditions. We stock Type B MCBs for domestic circuits and Type C MCBs for commercial/industrial loads, plus selected Type D options for specialist use. All are BS EN 60898 compliant and shipped with next-day UK delivery.

Read more

All our MCBs are clearly labelled, long-life tested, and essential in consumer units and three-phase boards to protect wiring and appliances. They disconnect circuits rapidly in the event of overload or fault, preventing damage and ensuring compliance with 18th Edition Wiring Regulations.

  • Type B MCBs – trip at 3–5x rated current; ideal for sockets and lighting
  • Type C MCBs – trip at 5–10x rated current; suited to motors, pumps, fluorescent lighting
  • Type D MCBs – trip at 10–20x rated current; specialist option for high inrush equipment

Looking for combined overload + earth leakage protection? See our RCBO range. For returns support, check our returns policy.

Showing 116 to 120 of 126 items
WKC 3 Pole 10kA MCB – 16A B Curve (WKC316B)

power-and-data-uk

WKC 3 Pole 10kA MCB – 16A B Curve (WKC316B)

£21.30

The WKC316B 3 Pole 10kA MCB is a 16A B Curve breaker built to protect three-phase circuits from overload and short-circuit faults. With a 10kA breaking capacity and full compliance with BS 7671 (18th Edition), it’s ideal for small commercial loads, EV charging boards, and...

WKC 3 Pole 10kA MCB – 10A D Curve (WKC310D)

power-and-data-uk

WKC 3 Pole 10kA MCB – 10A D Curve (WKC310D)

£21.30

The WKC310D 3 Pole 10kA MCB is a 10A D Curve breaker designed for three-phase circuits subject to high inrush currents. With a 10kA breaking capacity and full compliance with BS 7671 (18th Edition), it provides safe overload and short-circuit protection for industrial machinery, welders,...

WKC 3 Pole 10kA MCB – 10A C Curve (WKC310C)

power-and-data-uk

WKC 3 Pole 10kA MCB – 10A C Curve (WKC310C)

£21.30

The WKC310C 3 Pole 10kA MCB is a 10A C Curve breaker designed to protect three-phase circuits from short-circuit and overload faults. Rated at 10kA breaking capacity and BS 7671 (18th Edition) compliant, it’s widely used in industrial boards, EV chargers, and solar PV installs....

WKC 3 Pole 10kA MCB – 10A B Curve (WKC310B)

power-and-data-uk

WKC 3 Pole 10kA MCB – 10A B Curve (WKC310B)

£21.30

The WKC310B 3 Pole 10kA MCB is a 10A B Curve breaker designed to protect three-phase circuits against overloads and short-circuit faults. With a 10kA breaking capacity, it delivers safe disconnection in commercial and industrial boards, EV charging systems, and solar PV installations. Compact and...

WKC 3 Pole 10kA MCB – 6A D Curve (WKC306D)

power-and-data-uk

WKC 3 Pole 10kA MCB – 6A D Curve (WKC306D)

£21.30

The WKC306D 3 Pole 10kA MCB is a 6A D Curve breaker designed for protecting three-phase circuits with very high inrush currents. With a 10kA breaking capacity and compliance with BS 7671 (18th Edition), it is ideal for specialist industrial applications such as welders, transformers,...

What Is an MCB?

An MCB (Miniature Circuit Breaker) is an automatically operated switch that trips to protect circuits from overload (too much current) or short circuit faults. They replace traditional fuses, offering quicker reset, safer operation, and compliance with BS EN 60898.

Types of MCBs

  • Type B – trips at 3–5x rated current; standard for domestic circuits such as sockets and lighting. Popular choice: 10kA MCBs (Type B).
  • Type C – trips at 5–10x rated current; used for inductive/motor loads in workshops and commercial sites. Example: WKB 10kA MCBs.
  • Type D – trips at 10–20x rated current; for industrial kit with high inrush current (specialist use).

MCB Ratings & Sizes

MCBs come in a range of current ratings, typically from 6A to 100A. Choose the correct pole configuration and breaking capacity for your install:

  • Single pole – most domestic circuits
  • Double pole – where both live and neutral must be isolated
  • Three/four pole – used in three-phase distribution boards

Compliance

All our MCBs meet BS EN 60898 standards, making them fully compliant with the 18th Edition Wiring Regulations. This ensures safe disconnection times and compatibility with modern UK boards.

FAQs on MCBs

What’s the difference between an MCB and an RCBO?
An MCB protects against overloads and short circuits. An RCBO combines this with RCD protection for earth leakage faults.

How do I choose between Type B and Type C?
Use Type B for domestic circuits with low inrush currents (sockets, lighting). Use Type C for circuits with motors, pumps, or fluorescent lighting.

Do MCBs need replacing after they trip?
No – unlike fuses, MCBs can be reset once the fault is cleared, making them reusable and safer.

Why Buy From Power & Data UK?

All MCBs are UK stocked, BS EN compliant, and supplied with a 2-year warranty. Orders placed before 2pm ship same-day with next-day delivery on purchases over £30. If you need to return an item, see our returns policy.

Explore Related Categories