{"product_id":"wme08-sp-si","title":"8 Module Heat Pump Consumer Unit with Type B HP RCBOs + SPD (WME08\/SP-SI)","description":"\u003cp\u003e\u003cstrong\u003eBuilt to order – allow five working days after your order is received.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWME08\/SP-SI\u003c\/strong\u003e is a customer-specified \u003cstrong\u003e8-module heat pump consumer unit\u003c\/strong\u003e built around the WME08\/SP metal enclosure. It combines a \u003cstrong\u003e100A main switch\u003c\/strong\u003e and \u003cstrong\u003eType 2 surge protection\u003c\/strong\u003e with two \u003cstrong\u003e20A B-curve Type B HP RCBOs\u003c\/strong\u003e, a 20A B-curve MCB, a 16A B-curve MCB and a 32A Type A mini RCBO.\u003c\/p\u003e\n\u003cp\u003eThe two \u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"\/products\/heat-pump-rcbo-type-b-hp-single-module-20a-b-curve-rcbo-whr120b-030\"\u003eWHR120B-030 heat pump RCBOs\u003c\/a\u003e provide individual 30mA Type B HP residual-current and overcurrent protection for their respective circuits. The 20A and 16A MCBs provide overcurrent protection only; the 32A Type A RCBO provides its own 30mA residual-current and overcurrent protection. This mix gives the installer distinct protection options within one compact board, subject to the connected equipment and overall circuit design.\u003c\/p\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Note:\u003c\/strong\u003e The two fitted heat pump devices are \u003cstrong\u003eType B HP RCBOs\u003c\/strong\u003e, not a single shared Type B RCD. The MCB-protected circuits do not gain residual-current protection from those RCBOs. Check each circuit against the equipment manufacturer's requirements and the full installation design.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eWhat's included in this build?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge-protected enclosure:\u003c\/strong\u003e 1 × WME08\/SP metal board with 100A main switch and 20\/40kA SPD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType B HP RCBOs:\u003c\/strong\u003e 2 × \u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"\/products\/heat-pump-rcbo-type-b-hp-single-module-20a-b-curve-rcbo-whr120b-030\"\u003eWHR120B-030\u003c\/a\u003e – 20A B curve, 1P+N, 30mA, 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20A MCB:\u003c\/strong\u003e 1 × \u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"\/products\/6ka-mcb-20a-1-pole-b-curve-wmc120b\"\u003eWMC120B\u003c\/a\u003e – single-pole B curve, 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16A MCB:\u003c\/strong\u003e 1 × \u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"\/products\/6ka-mcb-16a-1-pole-b-curve-wmc116b\"\u003eWMC116B\u003c\/a\u003e – single-pole B curve, 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A RCBO:\u003c\/strong\u003e 1 × \u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"\/products\/a-type-mini-rcbo-32a-b-curve-high-immunity\"\u003eWRB132B-030\u003c\/a\u003e – 32A B curve, 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar:\u003c\/strong\u003e 1 × BB7 7-pin 100A pin-type busbar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection layout and capacity\u003c\/h3\u003e\n\u003cp\u003eThe WME08\/SP enclosure has \u003cstrong\u003efive usable outgoing ways\u003c\/strong\u003e. This build specifies five single-module outgoing devices, so there is \u003cstrong\u003eno spare outgoing way\u003c\/strong\u003e in the quoted arrangement. The metal enclosure is IP40 rated for indoor installation and measures \u003cstrong\u003e232 × 240 × 112 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe Type B HP designation refers to residual-current detection intended for heat pump applications where smooth DC and high-frequency leakage may be present. The B curve on the RCBOs and MCBs describes their separate overcurrent trip characteristic. Confirm the required ratings, RCD type and circuit coordination against the heat pump manufacturer’s instructions before ordering.\u003c\/p\u003e\n\u003ch3\u003eCompare related 8-module boards\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth scope=\"col\" style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProduct\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSupplied protection\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 10px; border: 1px solid #ddd;\"\u003eChoose when\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWME08\/SP-SI (this build)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e2 × 20A Type B HP RCBOs, 20A and 16A MCBs, 32A Type A RCBO, main switch and SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eThis exact five-device circuit schedule is specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"\/products\/wme-8-module-surge-protected-metal-enclosure-100a-main-switch-spd-wme08-sp\"\u003eWME08\/SP base board\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A main switch and SPD; outgoing devices not supplied\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eYou need to select your own outgoing devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"\/products\/heat-pump-consumer-unit-8-way-wme08-hpr40c\"\u003eWME08\/HPR40C heat pump board\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eShared Type B HP RCD with its separate MCB and RCBO configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eThe design calls for that different heat pump board arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eExplore \u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"\/collections\/heat-pump-boards\"\u003eheat pump consumer units\u003c\/a\u003e or \u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"\/collections\/8-way-consumer-units\"\u003e8-module consumer units\u003c\/a\u003e for other configurations. This listing is for the exact component schedule above. For an alternative build, email \u003ca style=\"color: #ff6d02; text-decoration: underline;\" href=\"mailto:sales@pandduk.com\"\u003esales@pandduk.com\u003c\/a\u003e with the required circuit details before ordering.\u003c\/p\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55628096504184,"sku":"WME08\/SP-SI","price":239.75,"currency_code":"GBP","in_stock":true}],"url":"https:\/\/poweranddatauk.co.uk\/products\/wme08-sp-si","provider":"power-and-data-uk","version":"1.0","type":"link"}