{"product_id":"heat-pump-consumer-unit-8-way-wme08-hpr40c","title":"Heat Pump Consumer Unit 8 Way (WME08\/HPR40C)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eWME08\/HPR40C Heat Pump Consumer Unit\u003c\/strong\u003e is a dedicated \u003ca href=\"\/collections\/heat-pump-boards\"\u003eheat pump protection board\u003c\/a\u003e designed for modern inverter-driven systems. This 8-way variant is supplied in a compact metal enclosure and fitted with a \u003cstrong\u003e40A Type B HP RCD\u003c\/strong\u003e, \u003cstrong\u003e1 x 16A C-curve MCB\u003c\/strong\u003e, \u003cstrong\u003e2 x 16A RCBOs\u003c\/strong\u003e, and an integrated \u003ca href=\"\/collections\/surge-protection\"\u003eType 2 surge protection device\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eIt is a strong fit for renewable installations where the heat pump circuit needs the correct high-frequency DC fault protection associated with Type B HP devices, while also allowing for extra outgoing circuit protection within the same board. Supplied pre-configured, it helps reduce assembly time and keeps the install neat, consistent, and ready for site wiring by a qualified electrician.\u003c\/p\u003e\n\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Note:\u003c\/strong\u003e This variant is designed for heat pump applications where smooth DC residual currents and higher-frequency fault conditions may be present. The fitted \u003cstrong\u003eType B HP RCD\u003c\/strong\u003e is intended for these inverter-driven environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eWhy choose the WME08\/HPR40C?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eWME08\/HPR40C\u003c\/strong\u003e gives you a more flexible factory-built layout than the standard 8-way board by including \u003cstrong\u003etwo fitted RCBOs\u003c\/strong\u003e alongside the main RCD, MCB, and SPD. That makes it a practical choice where extra circuit separation is needed without stepping up to a larger enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePurpose-built heat pump board:\u003c\/strong\u003e designed for inverter-driven heat pump installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory-fitted protection:\u003c\/strong\u003e 40A Type B HP RCD, 1 x 16A C-curve MCB, 2 x 16A RCBOs, and Type 2 SPD\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact enclosure:\u003c\/strong\u003e 232 x 240 x 112mm metal 8-module format\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCleaner installation:\u003c\/strong\u003e pre-configured board reduces on-site assembly time\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart of the Whitecliffe heat pump board range:\u003c\/strong\u003e available in alternative configurations and sizes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHeat pump board variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eVariant\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest For\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-wme-hp40c\"\u003e\u003cstrong\u003eWME08\/HP40C\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8-way board with Type B HP RCD, 16A C-curve MCBs and Type 2 SPD\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eStandard dedicated heat pump protection in a compact 8-way format\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\n        \u003cstrong\u003eWME08\/HPR40C\u003c\/strong\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8-way board with 40A Type B HP RCD, 1 x 16A C-curve MCB, 2 x 16A RCBOs and Type 2 SPD\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eInstallations needing extra outgoing circuit protection within the same compact enclosure\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-12-way-wme12-hp40c\"\u003e\u003cstrong\u003eWME12\/HP40C\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e12-way board with Type B HP RCD, 16A C-curve MCBs and Type 2 SPD\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eLarger installs or projects where additional spare ways are preferred for future expansion\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55511383409016,"sku":"WME08\/HPR40C","price":191.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WME12-HP40C.png?v=1750259257","url":"https:\/\/poweranddatauk.co.uk\/products\/heat-pump-consumer-unit-8-way-wme08-hpr40c","provider":"power-and-data-uk","version":"1.0","type":"link"}