{"title":"PME Fault Detection","description":"\u003ch1\u003ePEN Fault Detection Devices \u0026amp; PME Protection Units\u003c\/h1\u003e\n\n\u003cdiv class=\"collection-description\"\u003e\n  \u003cp\u003eOur \u003cstrong\u003ePEN fault detection devices\u003c\/strong\u003e and \u003cstrong\u003ePME protection units\u003c\/strong\u003e are used on EV charger installations and other outdoor supplies connected to TN-C-S \/ PME earthing systems. They monitor the supply and disconnect the circuit if a PEN fault is detected, helping prevent dangerous touch voltages on exposed conductive parts.\u003c\/p\u003e\n\n  \u003cp\u003eThis range includes standalone \u003cstrong\u003ePEN protection devices\u003c\/strong\u003e, \u003cstrong\u003ePME fault detection units\u003c\/strong\u003e, EV-ready boards and consumer units with integrated protection. Options are available for single-phase and three-phase installs, with SPD-ready configurations where surge protection is also required.\u003c\/p\u003e\n\n  \u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1rem 0;\"\u003e\n    \u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e A \u003cstrong\u003ePEN fault detection device\u003c\/strong\u003e, often called a \u003cstrong\u003ePME fault detection device\u003c\/strong\u003e or \u003cstrong\u003ePEN protection unit\u003c\/strong\u003e, monitors the incoming supply on TN-C-S systems. If a broken PEN conductor is detected, the device disconnects the load to reduce the risk of exposed metalwork becoming live.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdetails class=\"collection-details\"\u003e\n    \u003csummary\u003eRead more\u003c\/summary\u003e\n    \u003cdiv class=\"extra-content\"\u003e\n      \u003cp\u003eThese units are commonly specified for \u003cstrong\u003eEV charger installs\u003c\/strong\u003e where the charger or supply arrangement needs open PEN fault protection without relying on an earth rod. They are also used on some outdoor and renewable energy installations where PME-related risk needs to be managed correctly.\u003c\/p\u003e\n\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eEV charger PEN protection\u003c\/strong\u003e – suitable where open PEN fault detection is required\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSingle-phase and three-phase options\u003c\/strong\u003e – for domestic, commercial and multi-charge point installs\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eConsumer unit and standalone devices\u003c\/strong\u003e – choose a full PME board or separate protection unit\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSPD-ready configurations\u003c\/strong\u003e – selected units include surge protection for cleaner EV board specification\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n      \u003cp\u003eFor related EV protection, browse our \u003ca href=\"\/collections\/ev-kits\"\u003eEV-ready consumer units\u003c\/a\u003e, \u003ca href=\"\/collections\/surge-protection\"\u003esurge protection devices\u003c\/a\u003e and \u003ca href=\"\/collections\/type-b-rcds\"\u003eType B RCDs\u003c\/a\u003e.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e","products":[{"product_id":"wmepme12-lb-pme-board-with-load-balancing","title":"PME 12 Way Consumer Unit with Load Balancing (WMEPME12\/LB)","description":"\u003cp\u003e\u003cstrong\u003eSuitable for \u003ca href=\"\/collections\/three-phase\"\u003eSolar\u003c\/a\u003e \u0026amp; \u003ca href=\"\/collections\/ev-kits\"\u003eEV installations\u003c\/a\u003e\u003c\/strong\u003e, the PME \/ PEN Fault Detection \u003ca href=\"\/collections\/enclosures-consumer-units\"\u003eConsumer Unit\u003c\/a\u003e with Load Balancing is a built-to-order, 12-module \u003ca href=\"\/collections\/enclosures-1\"\u003emetal board\u003c\/a\u003e that protects against PME faults, PEN loss, voltage fluctuations, and overloads - while actively managing power demand. Designed for EV chargers without built-in PME protection, this unit delivers full compliance with \u003cstrong\u003eBS 7671:2018 (18th Edition, Amendment 2)\u003c\/strong\u003e and removes the need for an earth electrode\/rod.\u003c\/p\u003e\n\u003cp\u003eEquipped with a \u003ca href=\"\/products\/load-balance-monitoring-relay\"\u003eload balancing monitoring relay\u003c\/a\u003e, kilowatt-hour meter, \u003ca href=\"\/collections\/surge-protection\"\u003eType 2 surge protection device\u003c\/a\u003e, and \u003ca href=\"\/collections\/rcbos\"\u003eType A RCBO\u003c\/a\u003e, it’s ideal for properties with high-power appliances alongside EV charging - ensuring safe operation without nuisance tripping.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"PME Load Balancing Consumer Unit Diagram\" src=\"https:\/\/whitecliffe.co\/wp-content\/uploads\/2025\/02\/PME-with-load-balancing-spec-1024x564.webp\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic PME \/ PEN fault disconnection\u003c\/strong\u003e - isolates Live, Neutral \u0026amp; Earth within 5 seconds if voltage is outside 207–253V range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/load-balance-monitoring-relay\"\u003eLoad balancing relay\u003c\/a\u003e\u003c\/strong\u003e - 20A–110A adjustable sensitivity (IEC 60947-5-1 compliant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A Type A Double Pole \u003ca href=\"\/collections\/rcbos\"\u003eRCBO\u003c\/a\u003e\u003c\/strong\u003e - overload \u0026amp; 30mA fault current protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/surge-protection\"\u003eType 2 SPD\u003c\/a\u003e\u003c\/strong\u003e - shields against damaging voltage spikes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP40 metal enclosure\u003c\/strong\u003e - 12-module capacity with built-in contactor\u003c\/li\u003e\n\u003cli\u003eNo earth rod required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":42688838926488,"sku":"WMEPME12\/LB","price":186.85,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WMEPME12LB_c445859c-f95b-49b8-9374-617847e75049.png?v=1751297191"},{"product_id":"pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40","title":"PME Consumer Unit – 40A C Curve Type A RCBO, IP65 (WPEPME08\/C40)","description":"\u003cp\u003eThe \u003cstrong\u003eWPEPME08\/C40\u003c\/strong\u003e is an \u003cstrong\u003eIP65-rated PME consumer unit\u003c\/strong\u003e pre-fitted with a \u003cstrong\u003e40A C Curve Type A RCBO\u003c\/strong\u003e and integrated PME fault detection relays. It eliminates the need for an earth rod in \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e by safely isolating all conductors - live, neutral, and earth - if a PME or PEN fault is detected.\u003c\/p\u003e\n\u003cp\u003eHoused in a tough outdoor-ready enclosure, this unit is designed for \u003cstrong\u003eEV charge points\u003c\/strong\u003e, \u003cstrong\u003erenewable circuits\u003c\/strong\u003e, and \u003cstrong\u003edomestic or commercial installs\u003c\/strong\u003e that require full PME compliance. The built-in monitoring circuit continuously checks supply voltage and trips within 4–5 seconds on detection of unsafe conditions.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the C40 RCBO variant when you need \u003cstrong\u003eoverload + earth leakage protection\u003c\/strong\u003e built in. For additional surge defence, see the \u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp\"\u003eWPEPME08\/SP\u003c\/a\u003e model with integrated SPD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePME \/ PEN fault detection\u003c\/strong\u003e – disconnects all poles including earth within 4–5 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A C Curve Type A RCBO\u003c\/strong\u003e – overload, short circuit, and 30mA AC + 6mA DC leakage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65-rated enclosure\u003c\/strong\u003e – weatherproof for outdoor wall mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-reset after undervoltage\u003c\/strong\u003e, manual reset after overvoltage\u003c\/li\u003e\n\u003cli\u003ePre-configured and wired for fast installation\u003c\/li\u003e\n\u003cli\u003eComplies with \u003cstrong\u003eBS EN 61439-3\u003c\/strong\u003e and \u003cstrong\u003eBS 7671:2018 A2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare PME Consumer Unit Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBreaker\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEnclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWPEPME08\/C40 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/ip65-plastic-pen-fault-detection-unit-with-load-balancing-relay-kw-meter-wpepme12-lbk\"\u003e\n\u003cstrong\u003eWPEPME12\/LBK\u003c\/strong\u003e\n\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40A RCBO \/ 100A Main Switch\u003c\/td\u003e\n\u003ctd\u003ePME + Load Balancing + kWh Meter\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp\"\u003e\u003cstrong\u003eWPEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40\"\u003e\u003cstrong\u003eWPKPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-spd-ip65-wpkpme08-sp\"\u003e\u003cstrong\u003eWPKPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":54926982971768,"sku":"WPEPME08\/C40","price":115.35,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WPEPME08SP.png?v=1751296965"},{"product_id":"three-phase-pme-fault-detection-unit","title":"3 Phase PME Fault Detection Unit 100A (WARB5100C\/PME)","description":"\u003cp\u003e\u003cstrong\u003eThe \u003cstrong\u003eWARB5100C\/PME\u003c\/strong\u003e is a 3 phase PME fault detection unit supplied as a \u003cstrong\u003e100A MCB + PME relay\u003c\/strong\u003e configuration.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eAccording to the manufacturer, this unit automatically monitors the supply voltage on both \u003cstrong\u003e400V and 415V supplies\u003c\/strong\u003e without the need for manual dip switch settings. Within \u003cstrong\u003e5 seconds\u003c\/strong\u003e, if any phase drops below \u003cstrong\u003e207V\u003c\/strong\u003e or rises above \u003cstrong\u003e253V\u003c\/strong\u003e, \u003cstrong\u003elive, neutral and earth\u003c\/strong\u003e will be isolated.\u003c\/p\u003e\n\n\u003cp\u003eFollowing an under-voltage event, isolation will \u003cstrong\u003eautomatically reset\u003c\/strong\u003e when the normal operating range is restored. Following an over-voltage event, isolation will require a \u003cstrong\u003emanual reset\u003c\/strong\u003e on safety grounds using the \u003cstrong\u003ered button of the WP9\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e This base model is the \u003cstrong\u003e100A MCB + PME relay\u003c\/strong\u003e version only. If the project also requires surge or RCBO protection, choose one of the related PME variants below.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 phase PME fault detection\u003c\/strong\u003e – monitors 400V and 415V supplies automatically\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100A MCB + PME relay\u003c\/strong\u003e – base configuration for the range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnder-voltage isolation\u003c\/strong\u003e – trips if any phase falls below 207V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-voltage isolation\u003c\/strong\u003e – trips if any phase rises above 253V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response\u003c\/strong\u003e – isolates within 5 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset logic\u003c\/strong\u003e – auto reset after under-voltage recovery, manual reset after over-voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest Use Case\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWARB5100C\/PME (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBase option where PME fault detection is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-sp\"\u003e\u003cstrong\u003eWARB5100C\/PMESP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAdds surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-40r\"\u003e\u003cstrong\u003eWARB5100C\/PME40R\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAdds RCBO protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-40rsp\"\u003e\u003cstrong\u003eWARB5100C\/PME40RSP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO \/ SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAdds both RCBO and surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":54934455779704,"sku":"WARB5100C\/PME","price":90.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WARB5100C-PME40RSP_8ce1b769-a99a-40d3-a5fd-4911c28e65c5.png?v=1765293831"},{"product_id":"three-phase-pme-fault-detection-unit-sp","title":"3 Phase PME Fault Detection Unit SP (WARB5100C\/PMESP)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and built to order – allow up to 3 working days for dispatch.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWARB5100C\/PMESP\u003c\/strong\u003e is a \u003ca href=\"\/collections\/pme-fault-detection\"\u003e3 Phase PME Fault Detection Unit\u003c\/a\u003e with integrated \u003ca href=\"\/collections\/surge-protection\"\u003eType 2 surge protection\u003c\/a\u003e. It combines a \u003cstrong\u003e100A MCB main switch\u003c\/strong\u003e, PME relay, and SPD to deliver full PEN-loss protection plus transient surge suppression. Ideal for \u003ca href=\"\/collections\/ev-kits\"\u003eEV charging hubs\u003c\/a\u003e, solar PV systems, and commercial 3-phase sites, it ensures safe, regulation-compliant installs without the need for an earth rod.\u003c\/p\u003e\n\u003cp\u003eThe PME relay continuously monitors supply voltages across all three phases (400V \/ 415V). If \u003cstrong\u003eundervoltage\u003c\/strong\u003e is detected (below 207V), the unit disconnects automatically and resets once stable. If \u003cstrong\u003eovervoltage\u003c\/strong\u003e is detected (above 253V), the unit isolates and requires a \u003cstrong\u003emanual reset\u003c\/strong\u003e via the red button. Surge protection status is indicated via a clear visual display (Green = OK, Red = Replace).\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Always consider surge protection where sensitive electronics or EV chargers are present. This variant saves space by combining PME monitoring with a factory-fitted SPD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePME Fault Protection:\u003c\/strong\u003e Isolates all poles and earth on PEN loss\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100A MCB Main Switch:\u003c\/strong\u003e Overcurrent protection with clear isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType 2 SPD:\u003c\/strong\u003e Built-in surge protection with visual status indicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Monitoring:\u003c\/strong\u003e Detects undervoltage \u0026amp; overvoltage across all phases\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Functions:\u003c\/strong\u003e Auto reset on undervoltage recovery; manual reset for overvoltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets BS7671:2018+A2:2022 for PME \u0026amp; surge protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e EV hubs, solar PV systems, and commercial 3-phase supplies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest Use Case\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit\"\u003e\u003cstrong\u003eWARB5100C\/PME\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBase option for PME detection only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWARB5100C\/PMESP (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + Type 2 SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAdds surge protection for EV \u0026amp; solar sites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-40r\"\u003e\u003cstrong\u003eWARB5100C\/PME40R\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAdds overload \u0026amp; residual current protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-40rsp\"\u003e\u003cstrong\u003eWARB5100C\/PME40RSP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eFull coverage with surge + RCBO protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-63drsp\"\u003e\u003cstrong\u003eWARB5100C\/PME63DRSP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 63A RCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eHigher load three-phase installs with full protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55287055614328,"sku":"WARB5100C\/PMESP","price":121.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WARB5100C-PME40RSP_8ce1b769-a99a-40d3-a5fd-4911c28e65c5.png?v=1765293831"},{"product_id":"three-phase-pme-fault-detection-unit-40r","title":"3 Phase PME Fault Detection Unit 40R (WARB5100C\/PME40R)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and built to order – allow up to 3 working days for dispatch.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWARB5100C\/PME40R\u003c\/strong\u003e is a \u003ca href=\"\/collections\/pme-fault-detection\"\u003e3 Phase PME Fault Detection Unit\u003c\/a\u003e with integrated \u003ca href=\"\/collections\/rcbos\"\u003e40A Type A RCBO\u003c\/a\u003e. It combines a \u003cstrong\u003e100A MCB main switch\u003c\/strong\u003e, PME relay, and RCBO to deliver full PEN-loss protection plus overload and residual current protection for downstream circuits. Built for \u003ca href=\"\/collections\/ev-kits\"\u003eEV charging hubs\u003c\/a\u003e, solar installs, and 3-phase commercial supplies, it ensures a safe and regulation-compliant setup without the need for an earth rod.\u003c\/p\u003e\n\u003cp\u003eThe PME relay continuously monitors supply voltages across all three phases (400V \/ 415V). If \u003cstrong\u003eundervoltage\u003c\/strong\u003e is detected (below 207V), the unit disconnects automatically and resets once stable. If \u003cstrong\u003eovervoltage\u003c\/strong\u003e is detected (above 253V), it isolates and requires a \u003cstrong\u003emanual reset\u003c\/strong\u003e via the red button. This ensures safe fault management under BS7671:2018+A2:2022.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the 40R variant when you need combined overcurrent and residual current protection alongside PME monitoring. For sites also requiring surge protection, see the \u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-40rsp\"\u003e40RSP\u003c\/a\u003e model.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePME Fault Protection:\u003c\/strong\u003e Isolates all poles and earth on PEN loss\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100A MCB Main Switch:\u003c\/strong\u003e Provides upstream isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A Type A RCBO:\u003c\/strong\u003e Adds overload + residual current protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Monitoring:\u003c\/strong\u003e Detects undervoltage \u0026amp; overvoltage across phases\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Functions:\u003c\/strong\u003e Auto reset on undervoltage recovery; manual reset for overvoltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e BS7671:2018+A2:2022 PME requirements met\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e EV chargers, solar PV installs, and commercial 3-phase sites\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest Use Case\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit\"\u003e\u003cstrong\u003eWARB5100C\/PME\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBase option for PME detection only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-sp\"\u003e\u003cstrong\u003eWARB5100C\/PMESP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAdds surge protection for EV \u0026amp; solar sites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWARB5100C\/PME40R (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAdds overload + residual protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-40rsp\"\u003e\u003cstrong\u003eWARB5100C\/PME40RSP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eFull coverage with surge + RCBO protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-63drsp\"\u003e\u003cstrong\u003eWARB5100C\/PME63DRSP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 63A RCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eHigher load three-phase installs with full protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003ePlease Note*\u003c\/strong\u003e\u003c\/em\u003e The image is a WARB5100C\/PME for illustrative purposes only. Actual unit will come with a 40A RCBO included.\u003c\/p\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55287055942008,"sku":"WARB5100C\/PME40R","price":137.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WARD5100CPME_d20ab34e-ba30-4028-9c1d-6f42b568fff8.png?v=1765293831"},{"product_id":"three-phase-pme-fault-detection-unit-40rsp","title":"3 Phase PME Fault Detection Unit 40RSP (WARB5100C\/PME40RSP)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and built to order – allow up to 3 working days for dispatch.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWARB5100C\/PME40RSP\u003c\/strong\u003e is the all-in-one \u003ca href=\"\/collections\/pme-fault-detection\"\u003e3 Phase PME Fault Detection Unit\u003c\/a\u003e. It combines a \u003cstrong\u003e100A MCB main switch\u003c\/strong\u003e, integrated PME relay, a \u003ca href=\"\/collections\/rcbos\"\u003e40A Type A RCBO\u003c\/a\u003e, and a \u003ca href=\"\/collections\/surge-protection\"\u003eType 2 SPD\u003c\/a\u003e. This ensures full compliance with \u003cstrong\u003eBS7671:2018+A2:2022\u003c\/strong\u003e, protecting against PME\/PEN loss, overcurrent, residual leakage, and transient overvoltages – all in one board.\u003c\/p\u003e\n\u003cp\u003eDesigned for \u003ca href=\"\/collections\/ev-kits\"\u003eEV charging hubs\u003c\/a\u003e, solar PV, and 3-phase commercial installs, it gives installers a single-box solution for the highest level of site safety and fault resilience without requiring an earth rod.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background:#f9f9f9; padding:12px; border-left:4px solid #ff6d02; margin:16px 0;\"\u003e\n  \u003cp style=\"margin:0; font-size:14px; color:#444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e This variant provides the broadest protection in the PME range. Use it on critical EV\/renewable installs where full RCBO + SPD coverage is required to pass compliance and minimise downtime.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePME Fault Protection:\u003c\/strong\u003e Disconnects all poles \u0026amp; earth on PEN loss\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e40A RCBO:\u003c\/strong\u003e Adds overload + residual current protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType 2 SPD:\u003c\/strong\u003e Suppresses transient surges, visual status included\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100A MCB Main Switch:\u003c\/strong\u003e Upstream protection and isolation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Monitoring:\u003c\/strong\u003e Detects undervoltage \u0026amp; overvoltage across phases\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset Functions:\u003c\/strong\u003e Auto reset on undervoltage, manual reset for overvoltage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e EV chargepoints, PV systems, and sensitive 3-phase loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest Use Case\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit\"\u003e\u003cstrong\u003eWARB5100C\/PME\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBase PME-only protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-sp\"\u003e\u003cstrong\u003eWARB5100C\/PMESP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePME + surge suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-40r\"\u003e\u003cstrong\u003eWARB5100C\/PME40R\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAdds overload + leakage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWARB5100C\/PME40RSP (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eFull coverage for EV, solar \u0026amp; commercial installs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-63drsp\"\u003e\u003cstrong\u003eWARB5100C\/PME63DRSP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 63A RCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eHigher load installs with full protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55287056433528,"sku":"WARB5100C\/PME40RSP","price":141.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WARB5100C-PME40RSP_8ce1b769-a99a-40d3-a5fd-4911c28e65c5.png?v=1765293831"},{"product_id":"three-phase-pme-fault-detection-unit-63drsp","title":"3 Phase PME Fault Detection Unit 63DRSP (WARB5100C\/PME63DRSP)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and built to order – allow up to 3 working days for dispatch.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWARB5100C\/PME63DRSP\u003c\/strong\u003e is the flagship \u003ca href=\"\/collections\/pme-fault-detection\"\u003e3 Phase PME Fault Detection Unit\u003c\/a\u003e. It integrates a \u003cstrong\u003e100A MCB main switch\u003c\/strong\u003e, PME relay, a \u003ca href=\"\/collections\/rcbos\"\u003e63A Type A RCBO\u003c\/a\u003e, and a \u003ca href=\"\/collections\/surge-protection\"\u003eType 2 SPD\u003c\/a\u003e. Built for high-demand EV charging hubs, solar PV systems, and industrial 3-phase supplies, it provides the broadest compliance and protection in the range.\u003c\/p\u003e\n\u003cp\u003eThe PME relay continuously monitors all three phases at 400\/415V. If \u003cstrong\u003eundervoltage\u003c\/strong\u003e (below 207V) occurs, the board disconnects and auto-resets once stable. If \u003cstrong\u003eovervoltage\u003c\/strong\u003e (above 253V) occurs, it isolates and requires a \u003cstrong\u003emanual reset\u003c\/strong\u003e via the red button. This ensures safe, controlled recovery and compliance with \u003cstrong\u003eBS7671:2018+A2:2022\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background:#f9f9f9; padding:12px; border-left:4px solid #ff6d02; margin:16px 0;\"\u003e\n  \u003cp style=\"margin:0; font-size:14px; color:#444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the 63DRSP model for large commercial EV charger banks or heavy 3-phase renewables where a 40A RCBO isn’t sufficient. It’s the maximum protection available in this series.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePME Fault Detection:\u003c\/strong\u003e Isolates all poles \u0026amp; earth on PEN loss\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e63A Type A RCBO:\u003c\/strong\u003e Handles higher loads with overload + leakage protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType 2 SPD:\u003c\/strong\u003e Suppresses transient surges with visual indicator\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100A MCB Main Switch:\u003c\/strong\u003e Provides upstream protection and isolation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuto Monitoring:\u003c\/strong\u003e Continuous undervoltage \u0026amp; overvoltage detection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset Modes:\u003c\/strong\u003e Auto reset (undervoltage), manual reset (overvoltage)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e High-load EV charging sites, solar farms, industrial 3-phase systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest Use Case\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit\"\u003e\u003cstrong\u003eWARB5100C\/PME\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBase PME detection only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-sp\"\u003e\u003cstrong\u003eWARB5100C\/PMESP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePME + surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-40r\"\u003e\u003cstrong\u003eWARB5100C\/PME40R\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAdds overload \u0026amp; leakage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/three-phase-pme-fault-detection-unit-40rsp\"\u003e\u003cstrong\u003eWARB5100C\/PME40RSP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 40A RCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eFull coverage mid-load installs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWARB5100C\/PME63DRSP (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e100A MCB + PME Relay + 63A RCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eHigh-load EV \u0026amp; industrial systems with full protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55287056925048,"sku":"WARB5100C\/PME63DRSP","price":139.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WARB5100C-PME40RSP_8ce1b769-a99a-40d3-a5fd-4911c28e65c5.png?v=1765293831"},{"product_id":"pme-fault-detection-consumer-unit-4p-63a-rcbo-wmepme06-c40","title":"PME Fault Detection Consumer Unit – 4 Pole 63A RCBO (WMEPME06\/C40)","description":"\u003cp\u003eThe \u003cstrong\u003eWMEPME06\/C40 PME Fault Detection Consumer Unit\u003c\/strong\u003e is a compact \u003cstrong\u003e6-module metal board\u003c\/strong\u003e fitted with a \u003cstrong\u003e4 Pole 63A Type A RCBO\u003c\/strong\u003e. Designed for \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e and other PME applications, it provides automatic disconnection of \u003cstrong\u003eLive, Neutral, and Earth\u003c\/strong\u003e within 5 seconds if unsafe voltage conditions are detected. This keeps installs fully compliant with \u003cstrong\u003eBS 7671:2018 (18th Edition, Amendment 2)\u003c\/strong\u003e — eliminating the need for a separate earth rod.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e This unit ships with a \u003cstrong\u003eC Curve 63A RCBO\u003c\/strong\u003e, suitable for EV circuits where inrush currents are expected. If your specification calls for surge protection as well, consider the \u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme08-sp\"\u003eWMEPME08\/SP\u003c\/a\u003e or \u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme10-sp\"\u003eWMEPME10\/SP\u003c\/a\u003e variants.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated PEN fault detection\u003c\/strong\u003e – automatic voltage monitoring and safe disconnection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e63A Type A RCBO\u003c\/strong\u003e – 4 Pole, C Curve, 30mA fault protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo earth rod required\u003c\/strong\u003e – meets PME requirements under Amendment 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre-wired steel enclosure\u003c\/strong\u003e – 6-module width, IP40 rated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuick install\u003c\/strong\u003e – labelled terminals and compact footprint\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare PME Fault Detection Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModules\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWMEPME06\/C40 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO Only\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme08-sp\"\u003e\u003cstrong\u003eWMEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme10-sp\"\u003e\u003cstrong\u003eWMEPME10\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-wmepme10-lb\"\u003e\u003cstrong\u003eWMEPME10\/LB\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD + Load Balance\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO + Type 2 SPD + PME Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-kwh-meter-wmepme12-lbk\"\u003e\u003cstrong\u003eWMEPME12\/LBK\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD + Load Balance + kWh Meter\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO + SPD + PME Relay + Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288759845240,"sku":"WMEPME06\/C40","price":127.95,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WMEPME06_C40.png?v=1765977510"},{"product_id":"pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme08-sp","title":"PME Fault Detection Consumer Unit – 4 Pole 40A RCBO with SPD (WMEPME08\/SP)","description":"\u003cp\u003eThe \u003cstrong\u003eWMEPME08\/SP PME Fault Detection Consumer Unit\u003c\/strong\u003e is an \u003cstrong\u003e8-module metal board\u003c\/strong\u003e combining a \u003cstrong\u003e4 Pole 40A Type A RCBO\u003c\/strong\u003e with a \u003cstrong\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e. It delivers full PME\/PEN fault monitoring and automatic disconnection of \u003cstrong\u003eLive, Neutral, and Earth\u003c\/strong\u003e within 5 seconds if supply voltage moves outside safe limits. Fully compliant with \u003cstrong\u003eBS 7671:2018 (18th Edition, Amendment 2)\u003c\/strong\u003e, it removes the need for an earth rod while also safeguarding connected equipment from transient overvoltage events.\u003c\/p\u003e\n\u003cp\u003eDesigned for \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e and other PME applications where both PEN protection and surge resilience are required, this board gives installers a ready-to-fit, regulation-first solution.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The integrated \u003cstrong\u003eType 2 SPD\u003c\/strong\u003e protects both the charger and wider installation from transient surges — now mandatory on most new circuits. Keep the SPD earth lead as short as possible to maximise protection performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePEN fault detection\u003c\/strong\u003e – safe disconnection of Live, Neutral \u0026amp; Earth under dangerous voltages\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A Type A RCBO\u003c\/strong\u003e – 4 Pole, C Curve, 30mA residual protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType 2 SPD included\u003c\/strong\u003e – guards against transient voltage surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo earth rod required\u003c\/strong\u003e – fully PME compliant under Amendment 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-wired 8-module enclosure\u003c\/strong\u003e – installer-ready, IP40 steel case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare PME Fault Detection Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModules\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-wmepme06-c40\"\u003e\u003cstrong\u003eWMEPME06\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO Only\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e40A 4P RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWMEPME08\/SP (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e40A 4P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme10-sp\"\u003e\u003cstrong\u003eWMEPME10\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e40A 4P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-wmepme10-lb\"\u003e\u003cstrong\u003eWMEPME10\/LB\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD + Load Balance\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e40A 4P RCBO + SPD + PME Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-kwh-meter-wmepme12-lbk\"\u003e\u003cstrong\u003eWMEPME12\/LBK\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD + Load Balance + kWh Meter\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e40A 4P RCBO + SPD + PME Relay + Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288767349112,"sku":"WMEPME08\/SP","price":132.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WMEPME08SP_77015310-a8bb-4248-9dc5-72be3ec2f472.png?v=1765977510"},{"product_id":"pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme10-sp","title":"PME Fault Detection Consumer Unit – 4 Pole 63A RCBO with SPD (WMEPME10\/SP)","description":"\u003cp\u003eThe \u003cstrong\u003eWMEPME10\/SP PME Fault Detection Consumer Unit\u003c\/strong\u003e is a larger \u003cstrong\u003e10-module metal enclosure\u003c\/strong\u003e fitted with a \u003cstrong\u003e4 Pole 63A Type A RCBO\u003c\/strong\u003e and an integrated \u003cstrong\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e. It provides full PME\/PEN fault detection, automatically disconnecting \u003cstrong\u003eLive, Neutral, and Earth\u003c\/strong\u003e within 5 seconds under dangerous voltage conditions. Fully compliant with \u003cstrong\u003eBS 7671:2018 (18th Edition, Amendment 2)\u003c\/strong\u003e, this board eliminates the need for an earth rod while also protecting downstream equipment against transient surges.\u003c\/p\u003e\n\u003cp\u003eThe extra module space compared to the 8-way variant makes it a strong choice for installs where additional wiring room is needed or future expansion is likely. Ideal for \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e where PEN protection and surge resilience are both required.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the 10-module variant when you need extra wiring space for tails, isolators, or future expansion. It includes the same \u003cstrong\u003eRCBO + SPD protection\u003c\/strong\u003e as the WMEPME08\/SP but with more room for neat installs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated PEN fault detection\u003c\/strong\u003e – full isolation of Live, Neutral \u0026amp; Earth under fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e63A Type A RCBO\u003c\/strong\u003e – 4 Pole, C Curve, 30mA residual protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType 2 SPD\u003c\/strong\u003e – shields against transient voltage surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10-module steel enclosure\u003c\/strong\u003e – IP40 rated, pre-wired, installer-ready\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo earth rod required\u003c\/strong\u003e – compliant with PME installs under Amendment 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare PME Fault Detection Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModules\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-wmepme06-c40\"\u003e\u003cstrong\u003eWMEPME06\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO Only\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme08-sp\"\u003e\u003cstrong\u003eWMEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWMEPME10\/SP (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-wmepme10-lb\"\u003e\u003cstrong\u003eWMEPME10\/LB\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD + Load Balance\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO + SPD + PME Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-kwh-meter-wmepme12-lbk\"\u003e\u003cstrong\u003eWMEPME12\/LBK\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD + Load Balance + kWh Meter\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e63A 4P RCBO + SPD + PME Relay + Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288770134392,"sku":"WMEPME10\/SP","price":165.95,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WMEPME06_C40.png?v=1765977510"},{"product_id":"pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-kwh-meter-wmepme12-lbk","title":"PME Fault Detection Consumer Unit – 4 Pole 63A RCBO with SPD, Load Balancing \u0026 kWh Meter (WMEPME12\/LBK)","description":"\u003cp\u003eThe \u003cstrong\u003eWMEPME12\/LBK PME Fault Detection Consumer Unit\u003c\/strong\u003e is the largest model in the range, a \u003cstrong\u003e12-module steel enclosure\u003c\/strong\u003e combining a\u003cstrong\u003e 2 Pole 40A or 63A Type A RCBO\u003c\/strong\u003e, \u003cstrong\u003eB or C Curve\u003c\/strong\u003e, \u003cstrong\u003eType 2 SPD\u003c\/strong\u003e, \u003cstrong\u003ePME load balancing relay\u003c\/strong\u003e, and an integrated \u003cstrong\u003ekWh meter\u003c\/strong\u003e. It provides full PEN fault detection, surge protection, and automatic load management while also giving accurate energy monitoring of connected EV circuits. Fully compliant with \u003cstrong\u003eBS 7671:2018 (18th Edition, Amendment 2)\u003c\/strong\u003e, it eliminates the need for an earth rod and meets all DNO and inspection requirements for modern EV installs.\u003c\/p\u003e\n\u003cp\u003eThis is the all-in-one choice for \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e where PEN protection, surge resilience, demand control, and energy metering are all required in a single pre-wired board.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use this variant when clients need \u003cstrong\u003emetered EV circuits\u003c\/strong\u003e for monitoring consumption or billing. The integrated kWh meter saves space and avoids the need for a separate DIN-rail energy monitor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePEN fault detection\u003c\/strong\u003e – safe disconnection of Live, Neutral \u0026amp; Earth under fault conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A\/63A Type A RCBO\u003c\/strong\u003e – 2 Pole, C Curve, 30mA residual protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType 2 SPD\u003c\/strong\u003e – protects against transient surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePME load balancing relay\u003c\/strong\u003e – shares demand across multiple chargers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated kWh meter\u003c\/strong\u003e – enables consumption monitoring and reporting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-module IP40 enclosure\u003c\/strong\u003e – pre-wired, installer-ready\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare PME Fault Detection Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); width: 27.7281%;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); width: 30.4114%;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); width: 14.6691%;\"\u003eModules\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); width: 27.1914%;\"\u003eProtection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"width: 27.7281%;\"\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-wmepme06-c40\"\u003e\u003cstrong\u003eWMEPME06\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.4114%;\"\u003eRCBO Only\u003c\/td\u003e\n\u003ctd style=\"width: 14.6691%;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"width: 27.1914%;\"\u003e40A\/63A 2P RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7281%;\"\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme08-sp\"\u003e\u003cstrong\u003eWMEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.4114%;\"\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"width: 14.6691%;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"width: 27.1914%;\"\u003e40A\/63A 2P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"width: 27.7281%;\"\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme10-sp\"\u003e\u003cstrong\u003eWMEPME10\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.4114%;\"\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd style=\"width: 14.6691%;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"width: 27.1914%;\"\u003e40A\/63A 2P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7281%;\"\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-wmepme10-lb\"\u003e\u003cstrong\u003eWMEPME10\/LB\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.4114%;\"\u003eRCBO + SPD + Load Balance\u003c\/td\u003e\n\u003ctd style=\"width: 14.6691%;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"width: 27.1914%;\"\u003e40A\/63A 2P RCBO + SPD + PME Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"width: 27.7281%;\"\u003e\u003cstrong\u003eWMEPME12\/LBK (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.4114%;\"\u003eRCBO + SPD + Load Balance + kWh Meter\u003c\/td\u003e\n\u003ctd style=\"width: 14.6691%;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"width: 27.1914%;\"\u003e40A\/63A 2P RCBO + SPD + PME Relay + Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288795464056,"sku":"WMEPME12\/LBK","price":192.95,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WMEPME06_C40.png?v=1765977510"},{"product_id":"pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp","title":"PME Consumer Unit – 40A C Curve Type A RCBO + SPD, IP65 (WPEPME08\/SP)","description":"\u003cp\u003eThe \u003cstrong\u003eWPEPME08\/SP\u003c\/strong\u003e is an \u003cstrong\u003eIP65 PME consumer unit\u003c\/strong\u003e pre-fitted with a \u003cstrong\u003e40A C Curve Type A RCBO\u003c\/strong\u003e, integrated \u003cstrong\u003ePME fault detection relays\u003c\/strong\u003e, and a \u003cstrong\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e. It ensures EV charger installations comply with \u003cstrong\u003e18th Edition Amendment 2\u003c\/strong\u003e without the need for an earth rod, by disconnecting live, neutral, and earth conductors on detection of a PME or PEN fault.\u003c\/p\u003e\n\u003cp\u003eThis unit is ideal for \u003cstrong\u003eEV charge points\u003c\/strong\u003e, \u003cstrong\u003erenewable systems\u003c\/strong\u003e, and \u003cstrong\u003edomestic or commercial installs\u003c\/strong\u003e where both surge defence and PME compliance are required. The SPD protects against transient overvoltage events, while the RCBO provides full overload and leakage protection in one device.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the SP variant when \u003cstrong\u003esurge protection\u003c\/strong\u003e is required by design or client specification. For a simpler PME-only version, see the \u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40\"\u003eWPEPME08\/C40\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePME \/ PEN fault detection\u003c\/strong\u003e – trips all poles including earth within 4–5 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A C Curve Type A RCBO\u003c\/strong\u003e – overload, short circuit, and earth leakage protection (30mA AC + 6mA DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Type 2 SPD\u003c\/strong\u003e – transient surge protection, 20kA\/40kA rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 enclosure\u003c\/strong\u003e – weatherproof plastic housing for outdoor installs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset behaviour:\u003c\/strong\u003e Auto-reset after undervoltage, manual reset after overvoltage\u003c\/li\u003e\n\u003cli\u003eComplies with \u003cstrong\u003eBS EN 61439-3\u003c\/strong\u003e and \u003cstrong\u003eBS 7671:2018 A2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare PME Consumer Unit Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBreaker\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEnclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40\"\u003e\u003cstrong\u003eWPEPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWPEPME08\/SP (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/ip65-plastic-pen-fault-detection-unit-with-load-balancing-relay-kw-meter-wpepme12-lbk\"\u003e \u003cstrong\u003eWPEPME12\/LBK\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO \/ 100A Main Switch\u003c\/td\u003e\n\u003ctd\u003ePME + Load Balancing + kWh Meter\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40\"\u003e\u003cstrong\u003eWPKPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-spd-ip65-wpkpme08-sp\"\u003e\u003cstrong\u003eWPKPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295648629112,"sku":"WPEPME08\/SP","price":135.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WPEPME08SP.png?v=1751296965"},{"product_id":"pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40","title":"PME Consumer Unit – 40A MCB, IP65 (WPKPME08\/C40)","description":"\u003cp\u003eThe \u003cstrong\u003eWPKPME08\/C40\u003c\/strong\u003e is an \u003cstrong\u003eIP65-rated PME consumer unit\u003c\/strong\u003e pre-fitted with a \u003cstrong\u003e40A MCB\u003c\/strong\u003e and integrated PME fault detection relays. It removes the need for an earth rod in \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e by isolating live, neutral, and earth conductors if a PME or PEN fault is detected – ensuring compliance with \u003cstrong\u003e18th Edition Amendment 2\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis model is designed for \u003cstrong\u003eEV chargers\u003c\/strong\u003e and \u003cstrong\u003erenewable systems\u003c\/strong\u003e that already include DC leakage protection. The MCB provides overcurrent defence, while PME detection ensures safe isolation in the event of PEN faults. Housed in a robust \u003cstrong\u003eIP65 plastic enclosure\u003c\/strong\u003e, it’s ideal for both residential and commercial outdoor wall mounting.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the MCB variant when the \u003cstrong\u003eEV charger already includes its own RCD or RCBO functionality\u003c\/strong\u003e. For additional leakage protection in the unit itself, choose one of the \u003ca href=\"\/collections\/rcbos\"\u003eRCBO-based PME consumer units\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePME\/PEN fault detection\u003c\/strong\u003e – trips all conductors, including earth, within 4–5 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e40A MCB\u003c\/strong\u003e – overcurrent and short circuit protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP65 weatherproof enclosure\u003c\/strong\u003e – suitable for external mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset behaviour:\u003c\/strong\u003e Auto-reset after undervoltage, manual reset after overvoltage\u003c\/li\u003e\n  \u003cli\u003ePre-configured unit – supplied fully wired and ready to install\u003c\/li\u003e\n  \u003cli\u003eComplies with \u003cstrong\u003eBS EN 61439-3\u003c\/strong\u003e and \u003cstrong\u003eBS 7671:2018 A2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare PME Consumer Unit Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBreaker\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEnclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40\"\u003e\u003cstrong\u003eWPEPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp\"\u003e\u003cstrong\u003eWPEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWPKPME08\/C40 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-spd-ip65-wpkpme08-sp\"\u003e\u003cstrong\u003eWPKPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/ip65-plastic-pen-fault-detection-unit-with-load-balancing-relay-kw-meter-wpepme12-lbk\"\u003e\n\u003cstrong\u003eWPEPME12\/LBK\u003c\/strong\u003e\n\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40A RCBO \/ 100A Main Switch\u003c\/td\u003e\n\u003ctd\u003ePME + Load Balancing + kWh Meter\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295655707000,"sku":"WPKPME08\/C40","price":88.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WPEPME08SP.png?v=1751296965"},{"product_id":"pme-consumer-unit-40a-mcb-spd-ip65-wpkpme08-sp","title":"PME Consumer Unit – 40A MCB + SPD, IP65 (WPKPME08\/SP)","description":"\u003cp\u003eThe \u003cstrong\u003eWPKPME08\/SP\u003c\/strong\u003e is a weatherproof \u003cstrong\u003ePME consumer unit\u003c\/strong\u003e pre-fitted with a \u003cstrong\u003e40A MCB\u003c\/strong\u003e, integrated \u003cstrong\u003ePME fault detection relays\u003c\/strong\u003e, and a \u003cstrong\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e. It delivers full PEN fault isolation and surge protection in one compact \u003cstrong\u003eIP65 enclosure\u003c\/strong\u003e, removing the need for an earth rod in \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eDesigned for \u003cstrong\u003eEV charge points\u003c\/strong\u003e and \u003cstrong\u003erenewable installs\u003c\/strong\u003e that already include DC leakage protection, this model provides both \u003cstrong\u003eovercurrent defence\u003c\/strong\u003e and \u003cstrong\u003etransient surge suppression\u003c\/strong\u003e. The PME system automatically disconnects live, neutral, and earth conductors if a PEN fault is detected – keeping the installation safe and compliant with \u003cstrong\u003e18th Edition Amendment 2\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the SP variant when the \u003cstrong\u003edesign specifies surge protection\u003c\/strong\u003e for EV chargers or solar equipment. For PME-only use cases, see the \u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40\"\u003eWPKPME08\/C40\u003c\/a\u003e model.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePME\/PEN fault detection\u003c\/strong\u003e – trips all poles including earth within 4–5 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e40A MCB\u003c\/strong\u003e – protects against overcurrent and short circuits\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType 2 SPD\u003c\/strong\u003e – factory-fitted transient surge protection (20kA\/40kA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP65-rated enclosure\u003c\/strong\u003e – weatherproof polycarbonate\/ABS housing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset behaviour:\u003c\/strong\u003e Auto-reset after undervoltage, manual reset after overvoltage\u003c\/li\u003e\n  \u003cli\u003eSupplied pre-wired for fast installation\u003c\/li\u003e\n  \u003cli\u003eComplies with \u003cstrong\u003eBS EN 61439-3\u003c\/strong\u003e and \u003cstrong\u003eBS 7671:2018 A2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare PME Consumer Unit Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBreaker\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEnclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40\"\u003e\u003cstrong\u003eWPEPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp\"\u003e\u003cstrong\u003eWPEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40\"\u003e\u003cstrong\u003eWPKPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWPKPME08\/SP (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/ip65-plastic-pen-fault-detection-unit-with-load-balancing-relay-kw-meter-wpepme12-lbk\"\u003e\n\u003cstrong\u003eWPEPME12\/LBK\u003c\/strong\u003e\n\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40A RCBO \/ 100A Main Switch\u003c\/td\u003e\n\u003ctd\u003ePME + Load Balancing + kWh Meter\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295657410936,"sku":"WPKPME08\/SP","price":106.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WPEPME08SP.png?v=1751296965"},{"product_id":"ip65-plastic-pen-fault-detection-unit-with-load-balancing-relay-kw-meter-wpepme12-lbk","title":"PME Consumer Unit with Load Balancing \u0026 kWh Meter, IP65 (WPEPME12\/LBK)","description":"\u003cp\u003eThe \u003cstrong\u003eWPEPME12\/LBK\u003c\/strong\u003e is an \u003cstrong\u003eIP65-rated PME consumer unit\u003c\/strong\u003e combining \u003ca href=\"\/collections\/pme-fault-detection\"\u003e\u003cstrong\u003ePEN fault detection\u003c\/strong\u003e\u003c\/a\u003e, \u003cstrong\u003eadjustable load balancing\u003c\/strong\u003e, and an \u003cstrong\u003eintegrated kWh meter\u003c\/strong\u003e within a single enclosure. It is designed for \u003ca href=\"\/collections\/consumer-units\"\u003e\u003cstrong\u003econsumer unit\u003c\/strong\u003e\u003c\/a\u003e installations where supply capacity is limited and full compliance with \u003cstrong\u003eBS 7671:2018 Amendment 2\u003c\/strong\u003e is required.\u003c\/p\u003e\n\u003cp\u003eBy continuously monitoring supply voltage and current, the unit disconnects \u003cstrong\u003eLive, Neutral, and Earth\u003c\/strong\u003e within 4–5 seconds if a PME or PEN fault is detected, removing the need for an earth rod. The integrated load management relay uses a split-core CT to prevent the EV charger overloading the incoming supply, making it particularly effective on properties running multiple high-demand electrical loads.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose this model when you need \u003cstrong\u003ePME protection + load management\u003c\/strong\u003e in one unit - particularly useful on single-phase supplies where upgrading the incoming capacity isn’t practical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePME \/ PEN fault detection\u003c\/strong\u003e – disconnects Live, Neutral, and Earth within 4–5 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated load balancing relay\u003c\/strong\u003e – adjustable from 10A to 110A via CT clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in kWh meter\u003c\/strong\u003e – allows monitoring of EV charging energy usage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A Type A RCBO or 100A Main Switch variants\u003c\/strong\u003e – flexible protection options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65-rated enclosure\u003c\/strong\u003e – weatherproof for outdoor installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo earth rod required\u003c\/strong\u003e – fully compliant with Amendment 2 PME rules\u003c\/li\u003e\n\u003cli\u003eSupplied pre-wired for fast, consistent installation\u003c\/li\u003e\n\u003cli\u003eManufactured in compliance with \u003cstrong\u003eBS EN 61439-3\u003c\/strong\u003e and \u003cstrong\u003eBS 7671:2018 A2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare PME Consumer Unit Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBreaker\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection \u0026amp; Features\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEnclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWPEPME12\/LBK (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO \/ 100A Main Switch\u003c\/td\u003e\n\u003ctd\u003ePME + Load Balancing + kWh Meter\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40\"\u003e\u003cstrong\u003eWPEPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp\"\u003e\u003cstrong\u003eWPEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40\"\u003e\u003cstrong\u003eWPKPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-spd-ip65-wpkpme08-sp\"\u003e\u003cstrong\u003eWPKPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55442627166584,"sku":"WPEPME12\/LBK","price":211.4,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WPEPME12LB_056e6bbf-5b04-4515-9e72-81e66419a9e6.png?v=1751297064"},{"product_id":"pme-fault-detection-consumer-unit-4-pole-40a-rcbo-with-spd-wmepme08-sp-copy","title":"PME Fault Detection Consumer Unit – 4 Pole 32A RCBO with SPD (WMEPME08\/SP-C32)","description":"\u003cp\u003eThe \u003cstrong\u003eWMEPME08\/SP-C32 PME Fault Detection Consumer Unit\u003c\/strong\u003e is an \u003cstrong\u003e8-module metal board\u003c\/strong\u003e combining a \u003cstrong\u003e4 Pole 32A Type A RCBO\u003c\/strong\u003e with a \u003cstrong\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e. It delivers full PME\/PEN fault monitoring and automatic disconnection of \u003cstrong\u003eLive, Neutral, and Earth\u003c\/strong\u003e within 5 seconds if supply voltage moves outside safe limits. Fully compliant with \u003cstrong\u003eBS 7671:2018 (18th Edition, Amendment 2)\u003c\/strong\u003e, it removes the need for an earth rod while also safeguarding connected equipment from transient overvoltage events.\u003c\/p\u003e\n\u003cp\u003eDesigned for \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e and other PME applications where both PEN protection and surge resilience are required, this board gives installers a ready-to-fit, regulation-first solution.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The integrated \u003cstrong\u003eType 2 SPD\u003c\/strong\u003e protects both the charger and wider installation from transient surges — now mandatory on most new circuits. Keep the SPD earth lead as short as possible to maximise protection performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePEN fault detection\u003c\/strong\u003e – safe disconnection of Live, Neutral \u0026amp; Earth under dangerous voltages\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e32A Type A RCBO\u003c\/strong\u003e – 4 Pole, C Curve, 30mA residual protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType 2 SPD included\u003c\/strong\u003e – guards against transient voltage surges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo earth rod required\u003c\/strong\u003e – fully PME compliant under Amendment 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-wired 8-module enclosure\u003c\/strong\u003e – installer-ready, IP40 steel case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare PME Fault Detection Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModules\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-wmepme06-c40\"\u003e\u003cstrong\u003eWMEPME06\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO Only\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e40A 4P RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWMEPME08\/SP-C32 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e32A 4P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-wmepme10-sp\"\u003e\u003cstrong\u003eWMEPME10\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e40A 4P RCBO + Type 2 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-wmepme10-lb\"\u003e\u003cstrong\u003eWMEPME10\/LB\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD + Load Balance\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e40A 4P RCBO + SPD + PME Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-fault-detection-consumer-unit-4p-63a-rcbo-spd-load-balance-kwh-meter-wmepme12-lbk\"\u003e\u003cstrong\u003eWMEPME12\/LBK\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRCBO + SPD + Load Balance + kWh Meter\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e40A 4P RCBO + SPD + PME Relay + Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55625000485240,"sku":"WMEPME08\/SP","price":132.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WMEPME08SP_77015310-a8bb-4248-9dc5-72be3ec2f472.png?v=1765977510"}],"url":"https:\/\/poweranddatauk.co.uk\/collections\/pme-fault-detection.oembed?page=4","provider":"power-and-data-uk","version":"1.0","type":"link"}