{"title":"Heat Pump Consumer Units","description":"\u003ch1\u003eHeat Pump Consumer Units\u003c\/h1\u003e\n\n\u003cdiv class=\"collection-description\"\u003e\n  \u003cp\u003eOur \u003cstrong\u003eheat pump consumer units\u003c\/strong\u003e and \u003cstrong\u003eheat pump boards\u003c\/strong\u003e are built for dedicated air source, ground source and hybrid renewable heating supplies. They give installers a clear route for specifying \u003cstrong\u003eRCD protection\u003c\/strong\u003e, \u003cstrong\u003eRCBO protection\u003c\/strong\u003e and \u003ca href=\"\/collections\/surge-protection\"\u003esurge protection devices\u003c\/a\u003e where required for inverter-driven heat pump loads.\u003c\/p\u003e\n\n  \u003cp\u003eUse this range when you need a dedicated \u003cstrong\u003eheat pump power supply board\u003c\/strong\u003e rather than trying to adapt a standard domestic consumer unit. Options include pre-configured boards, Type A or Type B RCD protection, RCBO capacity and enclosures suited to renewable heating installations.\u003c\/p\u003e\n\n  \u003cdetails class=\"collection-details\"\u003e\n    \u003csummary\u003eRead more\u003c\/summary\u003e\n    \u003cdiv class=\"extra-content\"\u003e\n      \u003cp\u003eHeat pump circuits can place different demands on the electrical installation because of inverter-driven equipment, start-up current, control gear and wider renewable system integration. Choosing the right board helps keep the installation cleaner, easier to inspect and easier to expand later.\u003c\/p\u003e\n\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBuilt for heat pump installs\u003c\/strong\u003e – suitable for air source, ground source and hybrid renewable systems\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eRCD and RCBO options\u003c\/strong\u003e – choose suitable protection for the circuit design and manufacturer requirements\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSPD-ready protection\u003c\/strong\u003e – helps protect sensitive inverter and control equipment from transient overvoltage\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eInstaller-focused setup\u003c\/strong\u003e – useful where a dedicated heat pump fuse box or consumer unit is preferred\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n      \u003cp\u003eFor related protection options, view our \u003ca href=\"\/collections\/type-b-rcds\"\u003eType B RCDs\u003c\/a\u003e, \u003ca href=\"\/collections\/rcbos\"\u003eRCBOs\u003c\/a\u003e, \u003ca href=\"\/collections\/consumer-units\"\u003econsumer units\u003c\/a\u003e and \u003ca href=\"\/collections\/enclosures-1\"\u003eelectrical enclosures\u003c\/a\u003e.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e","products":[{"product_id":"pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40","title":"PME Consumer Unit – 40A C Curve Type A RCBO, IP65 (WPEPME08\/C40)","description":"\u003cp\u003eThe \u003cstrong\u003eWPEPME08\/C40\u003c\/strong\u003e is an \u003cstrong\u003eIP65-rated PME consumer unit\u003c\/strong\u003e pre-fitted with a \u003cstrong\u003e40A C Curve Type A RCBO\u003c\/strong\u003e and integrated PME fault detection relays. It eliminates the need for an earth rod in \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e by safely isolating all conductors - live, neutral, and earth - if a PME or PEN fault is detected.\u003c\/p\u003e\n\u003cp\u003eHoused in a tough outdoor-ready enclosure, this unit is designed for \u003cstrong\u003eEV charge points\u003c\/strong\u003e, \u003cstrong\u003erenewable circuits\u003c\/strong\u003e, and \u003cstrong\u003edomestic or commercial installs\u003c\/strong\u003e that require full PME compliance. The built-in monitoring circuit continuously checks supply voltage and trips within 4–5 seconds on detection of unsafe conditions.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the C40 RCBO variant when you need \u003cstrong\u003eoverload + earth leakage protection\u003c\/strong\u003e built in. For additional surge defence, see the \u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp\"\u003eWPEPME08\/SP\u003c\/a\u003e model with integrated SPD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePME \/ PEN fault detection\u003c\/strong\u003e – disconnects all poles including earth within 4–5 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A C Curve Type A RCBO\u003c\/strong\u003e – overload, short circuit, and 30mA AC + 6mA DC leakage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65-rated enclosure\u003c\/strong\u003e – weatherproof for outdoor wall mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-reset after undervoltage\u003c\/strong\u003e, manual reset after overvoltage\u003c\/li\u003e\n\u003cli\u003ePre-configured and wired for fast installation\u003c\/li\u003e\n\u003cli\u003eComplies with \u003cstrong\u003eBS EN 61439-3\u003c\/strong\u003e and \u003cstrong\u003eBS 7671:2018 A2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare PME Consumer Unit Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBreaker\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEnclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWPEPME08\/C40 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/ip65-plastic-pen-fault-detection-unit-with-load-balancing-relay-kw-meter-wpepme12-lbk\"\u003e\n\u003cstrong\u003eWPEPME12\/LBK\u003c\/strong\u003e\n\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40A RCBO \/ 100A Main Switch\u003c\/td\u003e\n\u003ctd\u003ePME + Load Balancing + kWh Meter\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp\"\u003e\u003cstrong\u003eWPEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40\"\u003e\u003cstrong\u003eWPKPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-spd-ip65-wpkpme08-sp\"\u003e\u003cstrong\u003eWPKPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":54926982971768,"sku":"WPEPME08\/C40","price":115.35,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WPEPME08SP.png?v=1751296965"},{"product_id":"heat-pump-consumer-unit-wme-hp40c","title":"Heat Pump Consumer Unit 8 Way (WME08\/HP40C)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWME08\/HP40C Heat Pump Consumer Unit\u003c\/strong\u003e is a dedicated protection board for \u003ca href=\"\/collections\/heat-pump-boards\"\u003einverter-driven heat pump systems\u003c\/a\u003e. It comes pre-fitted with a \u003ca href=\"\/products\/heap-pump-rcd-type-b-2-module-rcd-whp240-030\"\u003e40A Type B RCD\u003c\/a\u003e, a \u003ca href=\"\/products\/mcbs\"\u003e40A Type C MCB\u003c\/a\u003e, and a 2-pole \u003ca href=\"\/products\/single-module-surge-protection-device\"\u003eType 2 SPD\u003c\/a\u003e, giving full compliance with \u003cstrong\u003eBS 7671:2018+A2:2022\u003c\/strong\u003e. This ensures both surge protection and correct RCD specification for renewable installs.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e A \u003cstrong\u003eType B RCD\u003c\/strong\u003e is mandatory for inverter-driven heat pumps. Standard Type A devices may not detect smooth DC leakage and could leave the system unprotected.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhy Choose the 8-Way Version?\u003c\/h3\u003e\n\u003cp\u003eThe WME08\/HP40C offers all the required pre-fitted protection devices in a compact footprint. With 8 usable ways, it’s the ideal choice for smaller domestic installs or where board space is limited. For larger projects, see the \u003ca href=\"\/products\/heat-pump-consumer-unit-12-way-wme12-hp40c\"\u003e12-way version\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-fitted devices:\u003c\/strong\u003e 40A Type B RCD, 40A Type C 10kA MCB, 2P Type 2 SPD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact size:\u003c\/strong\u003e 232 × 240 × 112mm enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion ready:\u003c\/strong\u003e spare DIN space for future RCBOs or MCBs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant:\u003c\/strong\u003e BS 7671:2018+A2:2022 renewable regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable build:\u003c\/strong\u003e white powder-coated steel, surface mount with knockouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eVariant\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWME08\/HP40C (8-Way – This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8-way board with 40A Type B HP RCD, 16A C-curve MCBs and Type 2 SPD\u003cbr\u003e232 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eStandard dedicated heat pump protection in a compact 8-way format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/heat-pump-consumer-unit-8-way-wme08-hpr40c\"\u003e\u003cstrong\u003eWME08\/HPR40C (8-Way RCBO Variant)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8-way board with 40A Type B HP RCD, 1 x 16A C-curve MCB, 2 x 16A RCBOs and Type 2 SPD\u003cbr\u003e232 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eInstallations needing extra outgoing circuit protection within the same compact enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/heat-pump-consumer-unit-12-way-wme12-hp40c\"\u003e\u003cstrong\u003eWME12\/HP40C (12-Way)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e12-way board with 40A Type B HP RCD, 16A C-curve MCBs and Type 2 SPD\u003cbr\u003e304 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eLarger installs or where spare ways are needed for future expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55139900490104,"sku":"WME08\/HP40C","price":174.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WME12-HP40C.png?v=1750259257"},{"product_id":"heat-pump-consumer-unit-12-way-wme12-hp40c","title":"Heat Pump Consumer Unit 12 Way (WME12\/HP40C)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWME12\/HP40C Heat Pump Consumer Unit\u003c\/strong\u003e is a dedicated 12-way protection board designed for \u003ca href=\"\/collections\/heat-pump-boards\"\u003einverter-driven heat pump systems\u003c\/a\u003e. It comes pre-fitted with a \u003ca href=\"\/products\/heap-pump-rcd-type-b-2-module-rcd-whp240-030\"\u003e40A Type B RCD\u003c\/a\u003e, a \u003ca href=\"\/products\/mcbs\"\u003e40A Type C MCB\u003c\/a\u003e, and a 2-pole \u003ca href=\"\/products\/single-module-surge-protection-device\"\u003eType 2 SPD\u003c\/a\u003e. This ensures full compliance with \u003cstrong\u003eBS 7671:2018+A2:2022\u003c\/strong\u003e for surge and RCD requirements in renewable installs.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Always size boards for future expansion. The 12-way variant gives extra DIN capacity for \u003ca href=\"\/products\/a-type-rcbo\"\u003eRCBOs\u003c\/a\u003e or \u003ca href=\"\/products\/mcbs\"\u003eMCBs\u003c\/a\u003e without needing a second board.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhy Choose the 12-Way Version?\u003c\/h3\u003e\n\u003cp\u003eThe WME12\/HP40C offers the same pre-fitted protection devices as the 8-way but with \u003cstrong\u003eextra DIN space\u003c\/strong\u003e. This makes it ideal for larger domestic or light commercial projects, or where spare capacity is required for future circuits. For compact installs, see the \u003ca href=\"\/products\/heat-pump-consumer-unit-wme-hp40c\"\u003e8-way version\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-fitted devices:\u003c\/strong\u003e 40A Type B RCD, 40A Type C 10kA MCB, 2P Type 2 SPD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarger capacity:\u003c\/strong\u003e 12 usable ways, enclosure size 304 × 240 × 112mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion ready:\u003c\/strong\u003e more DIN space for RCBOs or MCBs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant:\u003c\/strong\u003e BS 7671:2018+A2:2022 renewable regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable build:\u003c\/strong\u003e white powder-coated steel, surface mount with knockouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eVariant\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/heat-pump-consumer-unit-wme-hp40c\"\u003e\u003cstrong\u003eWME08\/HP40C (8-Way)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8-way board with 40A Type B HP RCD, 16A C-curve MCBs and Type 2 SPD\u003cbr\u003e232 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eStandard dedicated heat pump protection in a compact 8-way format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/heat-pump-consumer-unit-8-way-wme08-hpr40c\"\u003e\u003cstrong\u003eWME08\/HPR40C (8-Way RCBO Variant)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8-way board with 40A Type B HP RCD, 1 x 16A C-curve MCB, 2 x 16A RCBOs and Type 2 SPD\u003cbr\u003e232 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eInstallations needing extra outgoing circuit protection within the same compact enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWME12\/HP40C (12-Way – This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e12-way board with 40A Type B HP RCD, 16A C-curve MCBs and Type 2 SPD\u003cbr\u003e304 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eLarger installs or where spare ways are needed for future expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55287019176312,"sku":"WME12\/HP40C","price":222.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WME12-HP40C.png?v=1750259257"},{"product_id":"pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp","title":"PME Consumer Unit – 40A C Curve Type A RCBO + SPD, IP65 (WPEPME08\/SP)","description":"\u003cp\u003eThe \u003cstrong\u003eWPEPME08\/SP\u003c\/strong\u003e is an \u003cstrong\u003eIP65 PME consumer unit\u003c\/strong\u003e pre-fitted with a \u003cstrong\u003e40A C Curve Type A RCBO\u003c\/strong\u003e, integrated \u003cstrong\u003ePME fault detection relays\u003c\/strong\u003e, and a \u003cstrong\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e. It ensures EV charger installations comply with \u003cstrong\u003e18th Edition Amendment 2\u003c\/strong\u003e without the need for an earth rod, by disconnecting live, neutral, and earth conductors on detection of a PME or PEN fault.\u003c\/p\u003e\n\u003cp\u003eThis unit is ideal for \u003cstrong\u003eEV charge points\u003c\/strong\u003e, \u003cstrong\u003erenewable systems\u003c\/strong\u003e, and \u003cstrong\u003edomestic or commercial installs\u003c\/strong\u003e where both surge defence and PME compliance are required. The SPD protects against transient overvoltage events, while the RCBO provides full overload and leakage protection in one device.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the SP variant when \u003cstrong\u003esurge protection\u003c\/strong\u003e is required by design or client specification. For a simpler PME-only version, see the \u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40\"\u003eWPEPME08\/C40\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePME \/ PEN fault detection\u003c\/strong\u003e – trips all poles including earth within 4–5 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A C Curve Type A RCBO\u003c\/strong\u003e – overload, short circuit, and earth leakage protection (30mA AC + 6mA DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Type 2 SPD\u003c\/strong\u003e – transient surge protection, 20kA\/40kA rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 enclosure\u003c\/strong\u003e – weatherproof plastic housing for outdoor installs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset behaviour:\u003c\/strong\u003e Auto-reset after undervoltage, manual reset after overvoltage\u003c\/li\u003e\n\u003cli\u003eComplies with \u003cstrong\u003eBS EN 61439-3\u003c\/strong\u003e and \u003cstrong\u003eBS 7671:2018 A2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare PME Consumer Unit Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBreaker\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEnclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40\"\u003e\u003cstrong\u003eWPEPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWPEPME08\/SP (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/ip65-plastic-pen-fault-detection-unit-with-load-balancing-relay-kw-meter-wpepme12-lbk\"\u003e \u003cstrong\u003eWPEPME12\/LBK\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO \/ 100A Main Switch\u003c\/td\u003e\n\u003ctd\u003ePME + Load Balancing + kWh Meter\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40\"\u003e\u003cstrong\u003eWPKPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-spd-ip65-wpkpme08-sp\"\u003e\u003cstrong\u003eWPKPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295648629112,"sku":"WPEPME08\/SP","price":120.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WPEPME08SP.png?v=1751296965"},{"product_id":"pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40","title":"PME Consumer Unit – 40A MCB, IP65 (WPKPME08\/C40)","description":"\u003cp\u003eThe \u003cstrong\u003eWPKPME08\/C40\u003c\/strong\u003e is an \u003cstrong\u003eIP65-rated PME consumer unit\u003c\/strong\u003e pre-fitted with a \u003cstrong\u003e40A MCB\u003c\/strong\u003e and integrated PME fault detection relays. It removes the need for an earth rod in \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e by isolating live, neutral, and earth conductors if a PME or PEN fault is detected – ensuring compliance with \u003cstrong\u003e18th Edition Amendment 2\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis model is designed for \u003cstrong\u003eEV chargers\u003c\/strong\u003e and \u003cstrong\u003erenewable systems\u003c\/strong\u003e that already include DC leakage protection. The MCB provides overcurrent defence, while PME detection ensures safe isolation in the event of PEN faults. Housed in a robust \u003cstrong\u003eIP65 plastic enclosure\u003c\/strong\u003e, it’s ideal for both residential and commercial outdoor wall mounting.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the MCB variant when the \u003cstrong\u003eEV charger already includes its own RCD or RCBO functionality\u003c\/strong\u003e. For additional leakage protection in the unit itself, choose one of the \u003ca href=\"\/collections\/rcbos\"\u003eRCBO-based PME consumer units\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePME\/PEN fault detection\u003c\/strong\u003e – trips all conductors, including earth, within 4–5 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e40A MCB\u003c\/strong\u003e – overcurrent and short circuit protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP65 weatherproof enclosure\u003c\/strong\u003e – suitable for external mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset behaviour:\u003c\/strong\u003e Auto-reset after undervoltage, manual reset after overvoltage\u003c\/li\u003e\n  \u003cli\u003ePre-configured unit – supplied fully wired and ready to install\u003c\/li\u003e\n  \u003cli\u003eComplies with \u003cstrong\u003eBS EN 61439-3\u003c\/strong\u003e and \u003cstrong\u003eBS 7671:2018 A2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare PME Consumer Unit Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBreaker\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEnclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40\"\u003e\u003cstrong\u003eWPEPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp\"\u003e\u003cstrong\u003eWPEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWPKPME08\/C40 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-spd-ip65-wpkpme08-sp\"\u003e\u003cstrong\u003eWPKPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/ip65-plastic-pen-fault-detection-unit-with-load-balancing-relay-kw-meter-wpepme12-lbk\"\u003e\n\u003cstrong\u003eWPEPME12\/LBK\u003c\/strong\u003e\n\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40A RCBO \/ 100A Main Switch\u003c\/td\u003e\n\u003ctd\u003ePME + Load Balancing + kWh Meter\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295655707000,"sku":"WPKPME08\/C40","price":88.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WPEPME08SP.png?v=1751296965"},{"product_id":"pme-consumer-unit-40a-mcb-spd-ip65-wpkpme08-sp","title":"PME Consumer Unit – 40A MCB + SPD, IP65 (WPKPME08\/SP)","description":"\u003cp\u003eThe \u003cstrong\u003eWPKPME08\/SP\u003c\/strong\u003e is a weatherproof \u003cstrong\u003ePME consumer unit\u003c\/strong\u003e pre-fitted with a \u003cstrong\u003e40A MCB\u003c\/strong\u003e, integrated \u003cstrong\u003ePME fault detection relays\u003c\/strong\u003e, and a \u003cstrong\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e. It delivers full PEN fault isolation and surge protection in one compact \u003cstrong\u003eIP65 enclosure\u003c\/strong\u003e, removing the need for an earth rod in \u003ca href=\"\/collections\/ev-kits\"\u003eEV charger installations\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eDesigned for \u003cstrong\u003eEV charge points\u003c\/strong\u003e and \u003cstrong\u003erenewable installs\u003c\/strong\u003e that already include DC leakage protection, this model provides both \u003cstrong\u003eovercurrent defence\u003c\/strong\u003e and \u003cstrong\u003etransient surge suppression\u003c\/strong\u003e. The PME system automatically disconnects live, neutral, and earth conductors if a PEN fault is detected – keeping the installation safe and compliant with \u003cstrong\u003e18th Edition Amendment 2\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the SP variant when the \u003cstrong\u003edesign specifies surge protection\u003c\/strong\u003e for EV chargers or solar equipment. For PME-only use cases, see the \u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40\"\u003eWPKPME08\/C40\u003c\/a\u003e model.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePME\/PEN fault detection\u003c\/strong\u003e – trips all poles including earth within 4–5 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e40A MCB\u003c\/strong\u003e – protects against overcurrent and short circuits\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType 2 SPD\u003c\/strong\u003e – factory-fitted transient surge protection (20kA\/40kA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP65-rated enclosure\u003c\/strong\u003e – weatherproof polycarbonate\/ABS housing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset behaviour:\u003c\/strong\u003e Auto-reset after undervoltage, manual reset after overvoltage\u003c\/li\u003e\n  \u003cli\u003eSupplied pre-wired for fast installation\u003c\/li\u003e\n  \u003cli\u003eComplies with \u003cstrong\u003eBS EN 61439-3\u003c\/strong\u003e and \u003cstrong\u003eBS 7671:2018 A2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare PME Consumer Unit Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBreaker\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProtection\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEnclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-ip65-wpepme08-c40\"\u003e\u003cstrong\u003eWPEPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-c-curve-type-a-rcbo-spd-ip65-wpepme08-sp\"\u003e\u003cstrong\u003eWPEPME08\/SP\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A RCBO (C Curve, Type A)\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pme-consumer-unit-40a-mcb-ip65-wpkpme08-c40\"\u003e\u003cstrong\u003eWPKPME08\/C40\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWPKPME08\/SP (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A MCB\u003c\/td\u003e\n\u003ctd\u003ePME + Type 2 SPD\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/ip65-plastic-pen-fault-detection-unit-with-load-balancing-relay-kw-meter-wpepme12-lbk\"\u003e\n\u003cstrong\u003eWPEPME12\/LBK\u003c\/strong\u003e\n\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40A RCBO \/ 100A Main Switch\u003c\/td\u003e\n\u003ctd\u003ePME + Load Balancing + kWh Meter\u003c\/td\u003e\n\u003ctd\u003eIP65 Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295657410936,"sku":"WPKPME08\/SP","price":106.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WPEPME08SP.png?v=1751296965"},{"product_id":"heat-pump-consumer-unit-10-way-wme10-hp40c","title":"Heat Pump Consumer Unit 10 Way (WME10\/HP40R16)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWME10\/HP40R16 Heat Pump Consumer Unit\u003c\/strong\u003e is a dedicated protection board for \u003ca href=\"\/collections\/heat-pump-boards\"\u003einverter-driven heat pump systems\u003c\/a\u003e. It comes pre-fitted with a \u003ca href=\"\/products\/heap-pump-rcd-type-b-2-module-rcd-whp240-030\"\u003e40A Type B RCD\u003c\/a\u003e, a \u003ca href=\"\/products\/mcbs\"\u003e16A MCB\u003c\/a\u003e, \u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003e3 x 16A RCBO\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(43, 0, 255); font-size: 0.875rem; text-decoration: underline;\"\u003e'\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem; color: rgb(43, 0, 255); text-decoration: underline;\"\u003es\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e, \u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003e100A\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003eMain Switch\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e and a 2-pole \u003c\/span\u003e\u003ca style=\"font-size: 0.875rem;\" href=\"\/products\/single-module-surge-protection-device\"\u003eType 2 SPD\u003c\/a\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e, giving full compliance with \u003c\/span\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eBS 7671:2018+A2:2022\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e. This ensures both surge protection and correct RCD specification for renewable installs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e A \u003cstrong\u003eType B RCD\u003c\/strong\u003e is mandatory for inverter-driven heat pumps. Standard Type A devices may not detect smooth DC leakage and could leave the system unprotected.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhy Choose the 10-Way Version?\u003c\/h3\u003e\n\u003cp\u003eThe WME10\/HP40R16 offers all the required pre-fitted protection devices in a compact footprint. With 10 usable ways, it’s the ideal choice for smaller domestic installs or where board space is limited. For larger projects, see the \u003ca href=\"\/products\/heat-pump-consumer-unit-12-way-wme12-hp40c\"\u003e12-way version\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-fitted devices:\u003c\/strong\u003e 40A Type B RCD, 100A M\/S, 16A MCB, 3 x 16A RCBO, 2P Type 2 SPD + Blank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact size:\u003c\/strong\u003e 232 × 240 × 112mm enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion ready:\u003c\/strong\u003e spare DIN space for future RCBO or MCB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant:\u003c\/strong\u003e BS 7671:2018+A2:2022 renewable regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable build:\u003c\/strong\u003e white powder-coated steel, surface mount with knockouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eVariant\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWME10\/HP40R16 (10-Way – This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePre-fitted with 40A Type B RCD, 16A MCB, 3 x 16A RCBO, 110A Main Switch,  2P Type 2 SPD + Blank\u003cbr\u003e232 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCompact installs with limited circuits, small domestic setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003ca href=\"\/products\/heat-pump-consumer-unit-12-way-wme12-hp40c\"\u003e\u003cstrong\u003eWME12\/HP40C (12-Way)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSame pre-fitted devices with extra DIN space\u003cbr\u003e304 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eLarger installs or where spare ways are needed for future RCBOs\/MCBs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55352743657848,"sku":"WME10\/HP40R16","price":224.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WME12-HP40C.png?v=1750259257"},{"product_id":"heat-pump-consumer-unit-10-way-wme10-hpr40c","title":"Heat Pump Consumer Unit 10 Way (WME10\/HP40R25)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWME10\/HP40R25 Heat Pump Consumer Unit\u003c\/strong\u003e is a dedicated protection board for \u003ca href=\"\/collections\/heat-pump-boards\"\u003einverter-driven heat pump systems\u003c\/a\u003e. It comes pre-fitted with a \u003ca href=\"\/products\/heap-pump-rcd-type-b-2-module-rcd-whp240-030\"\u003e40A Type B RCD\u003c\/a\u003e, a \u003ca href=\"\/products\/mcbs\"\u003e25A MCB\u003c\/a\u003e, \u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003e3 x 16A RCBO's, 100A Main Switch\u003c\/span\u003e and a 2-pole \u003ca href=\"\/products\/single-module-surge-protection-device\"\u003eType 2 SPD\u003c\/a\u003e, giving full compliance with \u003cstrong\u003eBS 7671:2018+A2:2022\u003c\/strong\u003e. This ensures both surge protection and correct RCD specification for renewable installs.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e A \u003cstrong\u003eType B RCD\u003c\/strong\u003e is mandatory for inverter-driven heat pumps. Standard Type A devices may not detect smooth DC leakage and could leave the system unprotected.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhy Choose the 10-Way Version?\u003c\/h3\u003e\n\u003cp\u003eThe WME10\/HPR40R25 offers all the required pre-fitted protection devices in a compact footprint. With 10 usable ways, it’s the ideal choice for smaller domestic installs or where board space is limited. For larger projects, see the \u003ca href=\"\/products\/heat-pump-consumer-unit-12-way-wme12-hp40c\"\u003e12-way version\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-fitted devices:\u003c\/strong\u003e 40A Type B RCD, 16A MCB, 3 x 16A RCBO, 110A Main Switch,  2P Type 2 SPD + Blank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact size:\u003c\/strong\u003e 232 × 240 × 112mm enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion ready:\u003c\/strong\u003e spare DIN space for future RCBOs or MCBs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant:\u003c\/strong\u003e BS 7671:2018+A2:2022 renewable regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable build:\u003c\/strong\u003e white powder-coated steel, surface mount with knockouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0px; font-size: 15px; text-align: left; height: 231px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: rgb(255, 109, 2); color: rgb(255, 255, 255); height: 21px;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); height: 21px;\"\u003eVariant\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); height: 21px;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); height: 21px;\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: rgb(249, 249, 249); height: 126px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); height: 126px;\"\u003e\u003cstrong\u003eWME10\/HP40R25 (10-Way – This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); height: 126px;\"\u003ePre-fitted with 40A Type B RCD, 25A MCB, 3 x 16A RCBO, 100A Main Switch,  2P Type 2 SPD + Blank\u003cbr\u003e232 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); height: 126px;\"\u003eCompact installs with limited circuits, small domestic setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 84px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); height: 84px;\"\u003e\u003ca href=\"\/products\/heat-pump-consumer-unit-12-way-wme12-hp40c\"\u003e\u003cstrong\u003eWME12\/HP40C (12-Way)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); height: 84px;\"\u003eSame pre-fitted devices with extra DIN space\u003cbr\u003e304 × 240 × 112mm enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(221, 221, 221); height: 84px;\"\u003eLarger installs or where spare ways are needed for future RCBOs\/MCBs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55352744935800,"sku":"WME10\/HP40R25","price":234.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WME12-HP40C.png?v=1750259257"},{"product_id":"heat-pump-consumer-unit-with-extra-usable-ways-wme10-sph","title":"Expandable Heat Pump Consumer Unit with Spare Ways – WME10\/SPH","description":"\u003cp\u003eThe \u003cstrong\u003eWME10\/SPH\u003c\/strong\u003e is an \u003cstrong\u003eexpandable heat pump consumer unit\u003c\/strong\u003e designed for installers who want to future-proof domestic properties. Built into a compact 10-way enclosure, it provides dedicated protection for a heat pump while leaving \u003cstrong\u003efour spare usable ways\u003c\/strong\u003e for additional circuits such as EV charging, solar PV, or battery storage.\u003c\/p\u003e\n\n\u003cp\u003eSupplied factory-assembled with a \u003cstrong\u003e100A main switch\u003c\/strong\u003e, \u003cstrong\u003eType 2 SPD\u003c\/strong\u003e, and \u003cstrong\u003eType B RCD\u003c\/strong\u003e, this unit delivers compliant protection for inverter-driven heat pumps while reducing on-site wiring time. The spare ways allow further technologies to be added later without installing additional consumer units.\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1.5rem 0;\"\u003e\n  \u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eInstaller note:\u003c\/strong\u003e Ideal for properties where a heat pump is being installed now, with plans to add EV charging or solar at a later date.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n  \u003cli\u003eExpandable heat pump consumer unit with spare usable ways\u003c\/li\u003e\n  \u003cli\u003eFactory-fitted 100A main switch\u003c\/li\u003e\n  \u003cli\u003eIntegrated Type 2 surge protection device (SPD)\u003c\/li\u003e\n  \u003cli\u003eType B RCD for inverter-driven heat pump protection\u003c\/li\u003e\n  \u003cli\u003e4 spare usable ways for future circuits\u003c\/li\u003e\n  \u003cli\u003eCompact 10-way metal enclosure\u003c\/li\u003e\n  \u003cli\u003e18th Edition Amendment 2 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDesigned for Future Expansion\u003c\/h3\u003e\n\u003cp\u003eThe WME10\/SPH is suited to \u003cstrong\u003edomestic heat pump installations\u003c\/strong\u003e where additional low-carbon technologies may be added later. The spare usable ways allow installers to integrate \u003cstrong\u003eEV chargers, solar PV, or battery storage\u003c\/strong\u003e without replacing the consumer unit.\u003c\/p\u003e\n\n\u003cp\u003eIf only a single heat pump circuit is required with no future expansion planned, a dedicated heat pump board may be sufficient. For larger properties or higher expansion requirements, larger expandable boards are available.\u003c\/p\u003e\n\n\n\u003ch3\u003eRelated Expandable Consumer Units\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #fff7f3;\"\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eProduct\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eUsable Ways\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eBest For\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/solar-consumer-unit-wme10-sol1\"\u003e\u003cstrong\u003eWME10\/SOL1\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eSolar-only\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eDedicated domestic solar PV installations\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003cstrong\u003eWME10\/SPH\u003c\/strong\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e4 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eCompact future-ready heat pump installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme12-sph\"\u003e\u003cstrong\u003eWME12\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e6 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHeat pump + EV or solar expansion\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme14-sph\"\u003e\u003cstrong\u003eWME14\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e8 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMedium-size domestic systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme16-sph\"\u003e\u003cstrong\u003eWME16\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e10 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eLarger homes or multiple future circuits\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme18-sph\"\u003e\u003cstrong\u003eWME18\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e12 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHigh-capacity domestic installations\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme22-sph\"\u003e\u003cstrong\u003eWME22\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e16 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMaximum expansion \u0026amp; multi-technology installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55416279040376,"sku":"WME10\/SPH","price":200.33,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/MG_5449-Heatpum-board.webp?v=1768321426"},{"product_id":"heat-pump-consumer-unit-with-extra-usable-ways-wme12-sph","title":"Expandable Heat Pump Consumer Unit with Spare Ways – WME12\/SPH","description":"\u003cp\u003eThe \u003cstrong\u003eWME12\/SPH\u003c\/strong\u003e is a \u003cstrong\u003e12-way expandable heat pump consumer unit\u003c\/strong\u003e designed for domestic installations where future electrical expansion is expected. It provides dedicated protection for a heat pump while leaving \u003cstrong\u003esix spare usable ways\u003c\/strong\u003e for additional circuits such as EV charging, solar PV, or battery storage.\u003c\/p\u003e\n\n\u003cp\u003eSupplied factory-assembled with a \u003cstrong\u003e100A main switch\u003c\/strong\u003e, \u003cstrong\u003eType 2 SPD\u003c\/strong\u003e, and \u003cstrong\u003eType B RCD\u003c\/strong\u003e, this consumer unit delivers compliant protection for inverter-driven heat pumps while significantly reducing on-site wiring time. The additional spare ways make it ideal for homeowners planning staged upgrades.\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1.5rem 0;\"\u003e\n  \u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eInstaller note:\u003c\/strong\u003e A strong choice where a heat pump is being installed now, with EV charging or solar PV planned for the near future.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n  \u003cli\u003eExpandable heat pump consumer unit with spare usable ways\u003c\/li\u003e\n  \u003cli\u003eFactory-fitted 100A main switch\u003c\/li\u003e\n  \u003cli\u003eIntegrated Type 2 surge protection device (SPD)\u003c\/li\u003e\n  \u003cli\u003eType B RCD for inverter-driven heat pump protection\u003c\/li\u003e\n  \u003cli\u003e6 spare usable ways for future circuits\u003c\/li\u003e\n  \u003cli\u003e12-way metal enclosure\u003c\/li\u003e\n  \u003cli\u003e18th Edition Amendment 2 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDesigned for Future Expansion\u003c\/h3\u003e\n\u003cp\u003eThe WME12\/SPH allows installers to consolidate multiple low-carbon technologies into a single consumer unit over time. Spare usable ways can be populated later for \u003cstrong\u003eEV chargers, solar PV inverters, battery storage, or auxiliary circuits\u003c\/strong\u003e without replacing the board.\u003c\/p\u003e\n\n\u003cp\u003eFor compact installs with limited expansion needs, a smaller board may be sufficient. For larger properties or multiple planned technologies, higher-capacity expandable boards are available.\u003c\/p\u003e\n\n\u003ch3\u003eRelated Expandable Consumer Units\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #fff7f3;\"\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eProduct\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eUsable Ways\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eBest For\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/solar-consumer-unit-wme10-sol1\"\u003e\u003cstrong\u003eWME10\/SOL1\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eSolar-only\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eDedicated domestic solar PV installations\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme10-sph\"\u003e\u003cstrong\u003eWME10\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e4 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eCompact future-ready heat pump installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003cstrong\u003eWME12\/SPH\u003c\/strong\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e6 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHeat pump + EV or solar expansion\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme14-sph\"\u003e\u003cstrong\u003eWME14\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e8 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMedium-size domestic systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme16-sph\"\u003e\u003cstrong\u003eWME16\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e10 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eLarger homes or multiple future circuits\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme18-sph\"\u003e\u003cstrong\u003eWME18\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e12 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHigh-capacity domestic installations\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme22-sph\"\u003e\u003cstrong\u003eWME22\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e16 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMaximum expansion \u0026amp; multi-technology installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55416280220024,"sku":"WME12\/SPH","price":191.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/MG_5449-Heatpum-board.webp?v=1768321426"},{"product_id":"heat-pump-consumer-unit-with-extra-usable-ways-wme14-sph","title":"Expandable Heat Pump Consumer Unit with Spare Ways – WME14\/SPH","description":"\u003cp\u003eThe \u003cstrong\u003eWME14\/SPH\u003c\/strong\u003e is a \u003cstrong\u003e14-way expandable heat pump consumer unit\u003c\/strong\u003e built for domestic installations where additional low-carbon technologies are planned. It provides dedicated protection for a heat pump while leaving \u003cstrong\u003eeight spare usable ways\u003c\/strong\u003e for future circuits such as EV charging, solar PV, or battery storage.\u003c\/p\u003e\n\n\u003cp\u003eSupplied factory-assembled with a \u003cstrong\u003e100A main switch\u003c\/strong\u003e, \u003cstrong\u003eType 2 SPD\u003c\/strong\u003e, and \u003cstrong\u003eType B RCD\u003c\/strong\u003e, this unit delivers compliant protection for inverter-driven heat pumps while reducing on-site wiring time. The increased spare capacity makes it ideal for larger homes or staged upgrade projects.\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1.5rem 0;\"\u003e\n  \u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eInstaller note:\u003c\/strong\u003e Ideal where a heat pump is installed now, with EV charging and solar PV planned as part of a phased upgrade.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n  \u003cli\u003eExpandable heat pump consumer unit with spare usable ways\u003c\/li\u003e\n  \u003cli\u003eFactory-fitted 100A main switch\u003c\/li\u003e\n  \u003cli\u003eIntegrated Type 2 surge protection device (SPD)\u003c\/li\u003e\n  \u003cli\u003eType B RCD for inverter-driven heat pump protection\u003c\/li\u003e\n  \u003cli\u003e8 spare usable ways for future circuits\u003c\/li\u003e\n  \u003cli\u003e14-way metal enclosure\u003c\/li\u003e\n  \u003cli\u003e18th Edition Amendment 2 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDesigned for Multi-Technology Installations\u003c\/h3\u003e\n\u003cp\u003eThe WME14\/SPH is well suited to properties adopting multiple low-carbon technologies over time. Spare ways allow additional circuits to be added later without replacing the consumer unit, helping installers future-proof the installation.\u003c\/p\u003e\n\n\u003cp\u003eThis board offers a strong balance between compact sizing and expansion capacity, making it a popular choice for medium-to-large domestic properties.\u003c\/p\u003e\n\n\u003ch3\u003eRelated Expandable Consumer Units\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #fff7f3;\"\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eProduct\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eUsable Ways\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eBest For\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/solar-consumer-unit-wme10-sol1\"\u003e\u003cstrong\u003eWME10\/SOL1\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eSolar-only\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eDedicated domestic solar PV installations\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme10-sph\"\u003e\u003cstrong\u003eWME10\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e4 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eCompact future-ready installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme12-sph\"\u003e\u003cstrong\u003eWME12\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e6 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHeat pump + single future upgrade\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003cstrong\u003eWME14\/SPH\u003c\/strong\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e8 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMedium-to-large domestic systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme16-sph\"\u003e\u003cstrong\u003eWME16\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e10 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eLarger homes or multi-tech installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme18-sph\"\u003e\u003cstrong\u003eWME18\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e12 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHigh-capacity domestic installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme22-sph\"\u003e\u003cstrong\u003eWME22\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e16 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMaximum expansion \u0026amp; future-proofing\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55416281825656,"sku":"WME14\/SPH","price":193.55,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/MG_5449-Heatpum-board.webp?v=1768321426"},{"product_id":"heat-pump-consumer-unit-with-extra-usable-ways-wme16-sph","title":"Expandable Heat Pump Consumer Unit with Spare Ways – WME16\/SPH","description":"\u003cp\u003eThe \u003cstrong\u003eWME16\/SPH\u003c\/strong\u003e is a \u003cstrong\u003e16-way expandable heat pump consumer unit\u003c\/strong\u003e designed for larger domestic installations where multiple low-carbon technologies are planned. It provides dedicated heat pump protection while offering \u003cstrong\u003eten spare usable ways\u003c\/strong\u003e for future circuits such as EV charging, solar PV, battery storage or auxiliary supplies.\u003c\/p\u003e\n\n\u003cp\u003eSupplied factory-assembled with a \u003cstrong\u003e100A main switch\u003c\/strong\u003e, \u003cstrong\u003eType 2 surge protection device (SPD)\u003c\/strong\u003e and \u003cstrong\u003eType B RCD\u003c\/strong\u003e, this board delivers compliant protection for inverter-driven heat pumps while significantly reducing installation time on site.\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1.5rem 0;\"\u003e\n  \u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eInstaller note:\u003c\/strong\u003e A strong choice for properties installing a heat pump now, with EV charging, solar PV or battery storage planned as future upgrades.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n  \u003cli\u003eExpandable heat pump consumer unit with high spare capacity\u003c\/li\u003e\n  \u003cli\u003eFactory-fitted 100A main switch\u003c\/li\u003e\n  \u003cli\u003eIntegrated Type 2 surge protection device (SPD)\u003c\/li\u003e\n  \u003cli\u003eType B RCD for inverter-driven heat pump protection\u003c\/li\u003e\n  \u003cli\u003e10 spare usable ways for future expansion\u003c\/li\u003e\n  \u003cli\u003e16-way metal enclosure\u003c\/li\u003e\n  \u003cli\u003e18th Edition Amendment 2 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBuilt for Larger, Multi-Technology Homes\u003c\/h3\u003e\n\u003cp\u003eThe WME16\/SPH is ideal for modern homes adopting multiple electrical technologies over time. Its higher spare capacity allows additional circuits to be added later without replacing the consumer unit, helping installers deliver long-term, future-proof solutions.\u003c\/p\u003e\n\n\u003cp\u003eThis board is particularly suited to larger properties where space, circuit separation and expansion headroom are critical.\u003c\/p\u003e\n\n\u003ch3\u003eRelated Expandable Consumer Units\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #fff7f3;\"\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eProduct\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eSpare Usable Ways\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eBest For\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/solar-consumer-unit-wme10-sol1\"\u003e\u003cstrong\u003eWME10\/SOL1\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eSolar-only\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eDedicated domestic solar PV installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme10-sph\"\u003e\u003cstrong\u003eWME10\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e4\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eCompact future-ready installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme12-sph\"\u003e\u003cstrong\u003eWME12\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e6\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHeat pump + single upgrade\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme14-sph\"\u003e\u003cstrong\u003eWME14\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e8\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMedium-to-large domestic installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003cstrong\u003eWME16\/SPH\u003c\/strong\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e10\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eLarge homes \/ multi-tech setups\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme18-sph\"\u003e\u003cstrong\u003eWME18\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e12\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHigh-capacity domestic systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme22-sph\"\u003e\u003cstrong\u003eWME22\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e16\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMaximum expansion \u0026amp; future-proofing\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55416282743160,"sku":"WME16\/SPH","price":197.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/MG_5449-Heatpum-board.webp?v=1768321426"},{"product_id":"heat-pump-consumer-unit-with-extra-usable-ways-wme18-sph","title":"Expandable Heat Pump Consumer Unit with Spare Ways – WME18\/SPH","description":"\u003cp\u003eThe \u003cstrong\u003eWME18\/SPH\u003c\/strong\u003e is an \u003cstrong\u003e18-way expandable heat pump consumer unit\u003c\/strong\u003e designed for high-capacity domestic installations where multiple future electrical technologies are planned. It provides dedicated protection for an inverter-driven heat pump while offering \u003cstrong\u003etwelve spare usable ways\u003c\/strong\u003e for additional circuits such as EV charging, solar PV, battery storage or auxiliary supplies.\u003c\/p\u003e\n\n\u003cp\u003eSupplied factory-assembled with a \u003cstrong\u003e100A main switch\u003c\/strong\u003e, \u003cstrong\u003eType 2 surge protection device (SPD)\u003c\/strong\u003e and \u003cstrong\u003eType B RCD\u003c\/strong\u003e, this unit delivers compliant protection while reducing on-site wiring time and simplifying commissioning on complex installs.\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1.5rem 0;\"\u003e\n  \u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eInstaller note:\u003c\/strong\u003e Ideal for larger homes where a heat pump is installed now, with EV charging, solar PV and battery storage planned as part of a staged upgrade.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n  \u003cli\u003eHigh-capacity expandable heat pump consumer unit\u003c\/li\u003e\n  \u003cli\u003eFactory-fitted 100A main switch\u003c\/li\u003e\n  \u003cli\u003eIntegrated Type 2 surge protection device (SPD)\u003c\/li\u003e\n  \u003cli\u003eType B RCD for inverter-driven heat pump protection\u003c\/li\u003e\n  \u003cli\u003e12 spare usable ways for future expansion\u003c\/li\u003e\n  \u003cli\u003e18-way metal enclosure\u003c\/li\u003e\n  \u003cli\u003e18th Edition Amendment 2 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDesigned for High-Capacity Domestic Installations\u003c\/h3\u003e\n\u003cp\u003eThe WME18\/SPH is built for properties with higher circuit demands and long-term electrification plans. Its generous spare capacity allows multiple technologies to be added over time without replacing the consumer unit.\u003c\/p\u003e\n\n\u003cp\u003eThis board is well suited to large domestic properties where circuit segregation, expandability and compliance are critical.\u003c\/p\u003e\n\n\u003ch3\u003eRelated Expandable Consumer Units\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #fff7f3;\"\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eProduct\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eSpare Usable Ways\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eBest For\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/solar-consumer-unit-wme10-sol1\"\u003e\u003cstrong\u003eWME10\/SOL1\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eSolar-only\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eDedicated domestic solar PV installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme10-sph\"\u003e\u003cstrong\u003eWME10\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e4\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eCompact future-ready installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme12-sph\"\u003e\u003cstrong\u003eWME12\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e6\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHeat pump + single upgrade\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme14-sph\"\u003e\u003cstrong\u003eWME14\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e8\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMedium-to-large domestic installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme16-sph\"\u003e\u003cstrong\u003eWME16\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e10\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eLarge homes \/ multi-tech setups\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003cstrong\u003eWME18\/SPH\u003c\/strong\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e12\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHigh-capacity domestic systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme22-sph\"\u003e\u003cstrong\u003eWME22\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e16\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMaximum expansion \u0026amp; future-proofing\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55416283103608,"sku":"WME18\/SPH","price":200.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/MG_5449-Heatpum-board.webp?v=1768321426"},{"product_id":"heat-pump-consumer-unit-with-extra-usable-ways-wme22-sph","title":"Expandable Heat Pump Consumer Unit with Spare Ways – WME22\/SPH","description":"\u003cp\u003eThe \u003cstrong\u003eWME22\/SPH\u003c\/strong\u003e is a \u003cstrong\u003e22-way expandable heat pump consumer unit\u003c\/strong\u003e designed for maximum future-proofing on high-capacity domestic installations. It provides dedicated protection for an inverter-driven heat pump while offering an exceptional \u003cstrong\u003esixteen spare usable ways\u003c\/strong\u003e for additional circuits such as EV charging, solar PV, battery storage and auxiliary supplies.\u003c\/p\u003e\n\n\u003cp\u003eSupplied factory-assembled with a \u003cstrong\u003e100A main switch\u003c\/strong\u003e, \u003cstrong\u003eType 2 surge protection device (SPD)\u003c\/strong\u003e and \u003cstrong\u003eType B RCD\u003c\/strong\u003e, this unit delivers a complete, compliant solution for modern electrified homes — reducing on-site wiring time while supporting long-term expansion without board replacement.\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1.5rem 0;\"\u003e\n  \u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eInstaller note:\u003c\/strong\u003e Ideal for high-end domestic projects where heat pump, EV charging, solar PV and battery storage are planned as part of a single long-term electrical strategy.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n  \u003cli\u003eFlagship expandable heat pump consumer unit\u003c\/li\u003e\n  \u003cli\u003eFactory-fitted 100A main switch\u003c\/li\u003e\n  \u003cli\u003eIntegrated Type 2 surge protection device (SPD)\u003c\/li\u003e\n  \u003cli\u003eType B RCD for inverter-driven heat pump protection\u003c\/li\u003e\n  \u003cli\u003e16 spare usable ways for extensive future expansion\u003c\/li\u003e\n  \u003cli\u003e22-way metal enclosure\u003c\/li\u003e\n  \u003cli\u003e18th Edition Amendment 2 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMaximum Expansion, One-Board Solution\u003c\/h3\u003e\n\u003cp\u003eThe WME22\/SPH is designed for properties where long-term electrification is planned from the outset. Its extensive spare capacity allows multiple technologies to be integrated over time without the need for additional consumer units or disruptive upgrades.\u003c\/p\u003e\n\n\u003cp\u003eThis board is particularly well suited to large domestic properties, new builds, or renovation projects where a single, centralised solution is preferred.\u003c\/p\u003e\n\n\u003ch3\u003eRelated Expandable Consumer Units\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #fff7f3;\"\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eProduct\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eSpare Usable Ways\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eBest For\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/solar-consumer-unit-wme10-sol1\"\u003e\u003cstrong\u003eWME10\/SOL1\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eSolar-only\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eDedicated domestic solar PV installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme10-sph\"\u003e\u003cstrong\u003eWME10\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e4\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eCompact future-ready installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme12-sph\"\u003e\u003cstrong\u003eWME12\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e6\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHeat pump + single upgrade\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme14-sph\"\u003e\u003cstrong\u003eWME14\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e8\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMedium-to-large domestic installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme16-sph\"\u003e\u003cstrong\u003eWME16\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e10\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eLarge homes \/ multi-tech setups\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme18-sph\"\u003e\u003cstrong\u003eWME18\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e12\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHigh-capacity domestic systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003cstrong\u003eWME22\/SPH\u003c\/strong\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e16\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMaximum expansion \u0026amp; future-proofing\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55416283332984,"sku":"WME22\/SPH","price":203.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/MG_5449-Heatpum-board.webp?v=1768321426"},{"product_id":"expandable-heat-pump-consumer-unit-with-spare-ways-wme08-sp-hpm","title":"Expandable Heat Pump Consumer Unit with Spare Ways – WME10\/SP\/HPM","description":"\u003cp\u003eThe \u003cstrong\u003eWME10\/SPH\u003c\/strong\u003e is an \u003cstrong\u003eexpandable heat pump consumer unit\u003c\/strong\u003e designed for installers who want to future-proof domestic properties. Built into a compact 10-way enclosure, it provides dedicated protection for a heat pump while leaving \u003cstrong\u003efour spare usable ways\u003c\/strong\u003e for additional circuits such as EV charging, solar PV, or battery storage.\u003c\/p\u003e\n\n\u003cp\u003eSupplied factory-assembled with a \u003cstrong\u003e100A main switch\u003c\/strong\u003e, \u003cstrong\u003eType 2 SPD\u003c\/strong\u003e, and \u003cstrong\u003eType B RCD\u003c\/strong\u003e, this unit delivers compliant protection for inverter-driven heat pumps while reducing on-site wiring time. The spare ways allow further technologies to be added later without installing additional consumer units.\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1.5rem 0;\"\u003e\n  \u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eInstaller note:\u003c\/strong\u003e Ideal for properties where a heat pump is being installed now, with plans to add EV charging or solar at a later date.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n  \u003cli\u003eExpandable heat pump consumer unit with spare usable ways\u003c\/li\u003e\n  \u003cli\u003eFactory-fitted 100A main switch\u003c\/li\u003e\n  \u003cli\u003eIntegrated Type 2 surge protection device (SPD)\u003c\/li\u003e\n  \u003cli\u003eType B RCD for inverter-driven heat pump protection\u003c\/li\u003e\n  \u003cli\u003e4 spare usable ways for future circuits\u003c\/li\u003e\n  \u003cli\u003eCompact 10-way metal enclosure\u003c\/li\u003e\n  \u003cli\u003e18th Edition Amendment 2 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDesigned for Future Expansion\u003c\/h3\u003e\n\u003cp\u003eThe WME10\/SPH is suited to \u003cstrong\u003edomestic heat pump installations\u003c\/strong\u003e where additional low-carbon technologies may be added later. The spare usable ways allow installers to integrate \u003cstrong\u003eEV chargers, solar PV, or battery storage\u003c\/strong\u003e without replacing the consumer unit.\u003c\/p\u003e\n\n\u003cp\u003eIf only a single heat pump circuit is required with no future expansion planned, a dedicated heat pump board may be sufficient. For larger properties or higher expansion requirements, larger expandable boards are available.\u003c\/p\u003e\n\n\n\u003ch3\u003eRelated Expandable Consumer Units\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #fff7f3;\"\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eProduct\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eUsable Ways\u003c\/th\u003e\n      \u003cth style=\"padding: 0.5rem; border: 1px solid #ddd; text-align: left;\"\u003eBest For\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/solar-consumer-unit-wme10-sol1\"\u003e\u003cstrong\u003eWME10\/SOL1\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eSolar-only\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eDedicated domestic solar PV installations\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003cstrong\u003eWME10\/SPH\u003c\/strong\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e4 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eCompact future-ready heat pump installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme12-sph\"\u003e\u003cstrong\u003eWME12\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e6 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHeat pump + EV or solar expansion\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme14-sph\"\u003e\u003cstrong\u003eWME14\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e8 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMedium-size domestic systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme16-sph\"\u003e\u003cstrong\u003eWME16\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e10 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eLarger homes or multiple future circuits\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme18-sph\"\u003e\u003cstrong\u003eWME18\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e12 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eHigh-capacity domestic installations\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-with-extra-usable-ways-wme22-sph\"\u003e\u003cstrong\u003eWME22\/SPH\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003e16 spare ways\u003c\/td\u003e\n      \u003ctd style=\"padding: 0.5rem; border: 1px solid #ddd;\"\u003eMaximum expansion \u0026amp; multi-technology installs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55494389498232,"sku":"WME10\/SPH","price":200.33,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/MG_5449-Heatpum-board.webp?v=1768321426"},{"product_id":"heat-pump-consumer-unit-8-way-wme08-hpr40c","title":"Heat Pump Consumer Unit 8 Way (WME08\/HPR40C)","description":"\u003cp\u003e\u003cstrong\u003ePre-wired in the UK and tested before dispatch – allow up to 3 working days for shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eWME08\/HPR40C Heat Pump Consumer Unit\u003c\/strong\u003e is a dedicated \u003ca href=\"\/collections\/heat-pump-boards\"\u003eheat pump protection board\u003c\/a\u003e designed for modern inverter-driven systems. This 8-way variant is supplied in a compact metal enclosure and fitted with a \u003cstrong\u003e40A Type B HP RCD\u003c\/strong\u003e, \u003cstrong\u003e1 x 16A C-curve MCB\u003c\/strong\u003e, \u003cstrong\u003e2 x 16A RCBOs\u003c\/strong\u003e, and an integrated \u003ca href=\"\/collections\/surge-protection\"\u003eType 2 surge protection device\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eIt is a strong fit for renewable installations where the heat pump circuit needs the correct high-frequency DC fault protection associated with Type B HP devices, while also allowing for extra outgoing circuit protection within the same board. Supplied pre-configured, it helps reduce assembly time and keeps the install neat, consistent, and ready for site wiring by a qualified electrician.\u003c\/p\u003e\n\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Note:\u003c\/strong\u003e This variant is designed for heat pump applications where smooth DC residual currents and higher-frequency fault conditions may be present. The fitted \u003cstrong\u003eType B HP RCD\u003c\/strong\u003e is intended for these inverter-driven environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eWhy choose the WME08\/HPR40C?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eWME08\/HPR40C\u003c\/strong\u003e gives you a more flexible factory-built layout than the standard 8-way board by including \u003cstrong\u003etwo fitted RCBOs\u003c\/strong\u003e alongside the main RCD, MCB, and SPD. That makes it a practical choice where extra circuit separation is needed without stepping up to a larger enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePurpose-built heat pump board:\u003c\/strong\u003e designed for inverter-driven heat pump installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory-fitted protection:\u003c\/strong\u003e 40A Type B HP RCD, 1 x 16A C-curve MCB, 2 x 16A RCBOs, and Type 2 SPD\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact enclosure:\u003c\/strong\u003e 232 x 240 x 112mm metal 8-module format\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCleaner installation:\u003c\/strong\u003e pre-configured board reduces on-site assembly time\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart of the Whitecliffe heat pump board range:\u003c\/strong\u003e available in alternative configurations and sizes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHeat pump board variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eVariant\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBest For\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-wme-hp40c\"\u003e\u003cstrong\u003eWME08\/HP40C\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8-way board with Type B HP RCD, 16A C-curve MCBs and Type 2 SPD\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eStandard dedicated heat pump protection in a compact 8-way format\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\n        \u003cstrong\u003eWME08\/HPR40C\u003c\/strong\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8-way board with 40A Type B HP RCD, 1 x 16A C-curve MCB, 2 x 16A RCBOs and Type 2 SPD\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eInstallations needing extra outgoing circuit protection within the same compact enclosure\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\n        \u003ca href=\"\/products\/heat-pump-consumer-unit-12-way-wme12-hp40c\"\u003e\u003cstrong\u003eWME12\/HP40C\u003c\/strong\u003e\u003c\/a\u003e\n      \u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e12-way board with Type B HP RCD, 16A C-curve MCBs and Type 2 SPD\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eLarger installs or projects where additional spare ways are preferred for future expansion\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55511383409016,"sku":"WME08\/HPR40C","price":191.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WME12-HP40C.png?v=1750259257"}],"url":"https:\/\/poweranddatauk.co.uk\/collections\/heat-pump-boards.oembed?page=3","provider":"power-and-data-uk","version":"1.0","type":"link"}