{"title":"B Curve RCBOs","description":"\u003ch1\u003eB Curve RCBOs for Domestic \u0026amp; Light Commercial Circuits\u003c\/h1\u003e\n\u003cdiv class=\"collection-description\"\u003e\n\u003cp\u003e\u003cstrong\u003eB Curve RCBOs\u003c\/strong\u003e are designed for standard domestic and light commercial circuits where inrush currents are low and predictable. They provide combined overcurrent and earth leakage protection in a single device, making them the preferred choice for modern boards where every circuit requires its own dedicated protection.\u003c\/p\u003e\n\u003cdetails class=\"collection-details\"\u003e\n\u003csummary\u003eRead more\u003c\/summary\u003e\n\u003cdiv class=\"extra-content\"\u003e\n\u003cp\u003eThese RCBOs trip within the B-curve range, meaning they respond quickly to fault currents that reach three to five times the rated current. This makes them ideal for lighting circuits, ring finals, small power circuits and general domestic loads. Most models include a switched neutral and are suitable for both new installs and retrofit upgrades.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombined MCB and RCD protection\u003c\/strong\u003e in one device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB-curve response\u003c\/strong\u003e for low-inrush domestic circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate disconnection times\u003c\/strong\u003e for 18th Edition compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched neutral options\u003c\/strong\u003e for improved testing and safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for tight consumer unit layouts\u003c\/strong\u003e due to compact module size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstallers choose B curve RCBOs for clean circuit separation, reduced nuisance tripping and simpler periodic inspection. All product dimensions and ratings are provided within the individual listings.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"background-color:#fff7f3; padding:1rem; border-left:4px solid #ff6d02; margin:1rem 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e A \u003cstrong\u003eB curve RCBO\u003c\/strong\u003e refers to the magnetic trip characteristic (3–5× rated current). This is different from a \u003cstrong\u003eType B RCBO\u003c\/strong\u003e, which relates to DC earth leakage detection for EV or inverter systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e","products":[{"product_id":"high-immunity-type-a-rcbo-20a-b-curve-30ma-wer20b-030","title":"High Immunity RCBO – 20A B Curve, Type A, 30mA (WER20B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWER20B-030\u003c\/strong\u003e is a \u003cstrong\u003e20A B Curve High Immunity Type A RCBO\u003c\/strong\u003e designed for residential and light commercial circuits including \u003cstrong\u003esolar PV, battery storage, and EV-ready boards\u003c\/strong\u003e. It combines \u003cstrong\u003eoverload, short-circuit, and 30mA residual current protection\u003c\/strong\u003e in one device, while its high immunity design helps prevent nuisance tripping in inverter-fed or noisy environments.\u003c\/p\u003e\n\u003cp\u003eFeaturing \u003cstrong\u003edouble pole disconnection\u003c\/strong\u003e and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e, this RCBO is a versatile choice for compliance with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The \u003cstrong\u003eB Curve\u003c\/strong\u003e is typically used for lighting and socket circuits where low inrush current is expected. For EV chargers, motors, or heat pump circuits, choose the C Curve version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20A B Curve Type A RCBO\u003c\/strong\u003e – protects against overload, short-circuit and earth leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity\u003c\/strong\u003e – resists nuisance trips from harmonics and transients\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30mA sensitivity\u003c\/strong\u003e – compliant with Amendment 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – suitable for residential and light commercial installs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble pole disconnection\u003c\/strong\u003e – safe isolation of live and neutral\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – line\/load reversible for solar \u0026amp; EV systems\u003c\/li\u003e\n\u003cli\u003eComplies with \u003cstrong\u003eBS EN 61009\u003c\/strong\u003e \u0026amp; \u003cstrong\u003e18th Edition Wiring Regulations\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare High Immunity RCBOs\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06b\"\u003e\u003cstrong\u003eWER06B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eLighting and other low inrush final circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06c\"\u003e\u003cstrong\u003eWER06C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLow-rated circuits where higher inrush tolerance is preferred\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-b-curve-30ma-wer16b-030\"\u003e\u003cstrong\u003eWER16B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eGeneral domestic final circuits with low inrush loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-c-curve-30ma-wer16c-030\"\u003e\u003cstrong\u003eWER16C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eSmall motors and circuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWER20B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eDomestic final circuits requiring a higher current rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-c-curve-30ma-wer20c-030\"\u003e\u003cstrong\u003eWER20C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eCircuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-b-curve-30ma-wer32b-030\"\u003e\u003cstrong\u003eWER32B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eRing finals and other standard appliance circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-c-curve-30ma-wer32c-030\"\u003e\u003cstrong\u003eWER32C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHigher demand circuits and loads with greater inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-b-curve-30ma-wer40b-030\"\u003e\u003cstrong\u003eWER40B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eHigher load circuits with lower inrush characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-c-curve-30ma-wer40c-030\"\u003e\u003cstrong\u003eWER40C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHeavier-duty circuits with higher inrush conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-63a-c-curve-type-a-30ma\"\u003e\u003cstrong\u003eWER63C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLarger commercial or high-load applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":42065212211352,"sku":"WER20B-030","price":19.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WER40B-030.png?v=1760363829"},{"product_id":"type-a-rcbo-6a-b-curve-30ma-wrt106b-030","title":"Type A RCBO – 6A B Curve, 30mA","description":"\u003cp\u003eThe \u003cstrong\u003eWRT106B-030\u003c\/strong\u003e is a \u003cstrong\u003e6A B Curve Type A RCBO\u003c\/strong\u003e providing \u003cstrong\u003ecombined residual current and overcurrent protection\u003c\/strong\u003e in one compact device. It features \u003cstrong\u003eswitched live and neutral disconnection\u003c\/strong\u003e for full isolation, \u003cstrong\u003ebi-directional operation\u003c\/strong\u003e for solar PV and inverter-fed circuits, and a \u003cstrong\u003ehigh immunity design\u003c\/strong\u003e to minimise nuisance tripping.\u003c\/p\u003e\n\u003cp\u003eTested to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e, this RCBO meets the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e and is suitable for \u003cstrong\u003edomestic lighting, small socket circuits, and renewable applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The \u003cstrong\u003eB Curve\u003c\/strong\u003e is ideal for domestic lighting or small loads with low inrush current. For motors, EV chargers, or circuits with high inrush, use the C Curve version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6A B Curve Type A RCBO\u003c\/strong\u003e – overload + residual protection in one unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – complete circuit isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity\u003c\/strong\u003e – reduces nuisance trips from harmonics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – suitable for solar and inverter systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact single-module design\u003c\/strong\u003e – 18mm DIN rail mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – suitable for residential and light commercial installs\u003c\/li\u003e\n\u003cli\u003eConforms to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare WRT Range\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT106B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eLighting \/ Small Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-6a-c-curve-30ma-wrt106c-030\"\u003e\u003cstrong\u003eWRT106C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eMotors \/ EV \/ Inrush Loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-16a-b-curve-30ma-wrt116b-030\"\u003e\u003cstrong\u003eWRT116B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eGeneral Domestic Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-16a-c-curve-30ma-wrt116c-030\"\u003e\u003cstrong\u003eWRT116C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eEV \/ Heat Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":54920396931448,"sku":"WRT106B-030","price":14.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT116B-030.png?v=1754319758"},{"product_id":"arc-fault-detection-a-type-rcbo-wfd1-b-030","title":"Arc Fault Detection A-Type RCBO – WFD106B-030 (6A, B Curve, 30mA)","description":"\u003cp\u003eThe \u003cstrong\u003eWFD106B-030\u003c\/strong\u003e is a \u003cstrong\u003e6A, B Curve Arc Fault Detection (AFDD) RCBO\u003c\/strong\u003e, combining arc fault detection, residual current protection (30mA), short-circuit, and overload protection into a single compact module. Built to \u003cstrong\u003eBS 7671:2018 (18th Edition)\u003c\/strong\u003e standards, it delivers the highest level of fire prevention for modern installations.\u003c\/p\u003e\n\u003cp\u003eUnlike a standard \u003ca href=\"\/collections\/rcbos\"\u003eRCBO\u003c\/a\u003e, this device features a microprocessor-controlled \u003cstrong\u003eArc Fault Detection Device (AFDD)\u003c\/strong\u003e. It continuously monitors the electrical waveform, identifying dangerous arcs caused by \u003cstrong\u003eworn wiring, poor terminations, ageing circuits, or faulty appliances\u003c\/strong\u003e. When detected, it trips instantly, disconnecting live and neutral conductors to eliminate fire risk.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The 6A model is best suited to lighting circuits in HMOs, rental properties, hotels, and other sleeping accommodation where fire prevention is critical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProtective Coverage\u003c\/h3\u003e\n\u003cp\u003eThe WFD1 series combines AFDD, MCB, and Type A RCD functionality, protecting against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc faults\u003c\/strong\u003e – series and parallel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload and short-circuit\u003c\/strong\u003e events\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual current leakage\u003c\/strong\u003e – Type A (AC + pulsating DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage conditions\u003c\/strong\u003e – trips at 275V ±5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSensitivity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWFD106B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd110b-030\"\u003e\u003cstrong\u003eWFD110B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd116b-030\"\u003e\u003cstrong\u003eWFD116B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd120b-030\"\u003e\u003cstrong\u003eWFD120B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd132b-030\"\u003e\u003cstrong\u003eWFD132B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd140b-030\"\u003e\u003cstrong\u003eWFD140B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55139778167160,"sku":"WFD106B-030","price":96.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WFD132C-030.png?v=1750259288"},{"product_id":"single-module-2-pole-rcbo-16a-b-curve-wrn16b-030","title":"Single Module 2 Pole RCBO 16A B Curve WRN16B-030","description":"\u003cp\u003eThe \u003cstrong\u003eWRN16B-030\u003c\/strong\u003e is a compact \u003cstrong\u003e16A Type A RCBO\u003c\/strong\u003e in a single-module, 2-pole format - combining residual current (RCD) and overcurrent (MCB) protection in one device. Designed to detect both AC and pulsating DC leakage, it ensures compliance with \u003cstrong\u003e18th Edition BS 7671\u003c\/strong\u003e wiring regulations across domestic and commercial installs. With a switched live and neutral, the WRN range guarantees full disconnection during a fault, isolating only the affected circuit and keeping healthy circuits in service.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The WRN range comes with a switched neutral as standard - essential for full circuit isolation and safer maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16A B-Curve RCBO:\u003c\/strong\u003e Handles standard domestic and light commercial loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A protection:\u003c\/strong\u003e Trips on AC and pulsating DC residual currents\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace-saving design:\u003c\/strong\u003e Single 18mm module width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-pole with switched neutral:\u003c\/strong\u003e Disconnects both conductors on fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimises disruption:\u003c\/strong\u003e Isolates only the faulty circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBS 7671 compliant:\u003c\/strong\u003e Suitable for Amendment 2 installs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55285563883896,"sku":"WRN16B-030","price":18.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRN-side.webp?v=1758639151"},{"product_id":"single-module-2-pole-rcbo-32a-b-curve-wrn32b-030","title":"Single Module 2 Pole RCBO 32A B Curve WRN32B-030","description":"\u003cp\u003eThe \u003cstrong\u003eWRN32B-030\u003c\/strong\u003e is a \u003cstrong\u003e32A Type A RCBO\u003c\/strong\u003e in a compact single-module, 2-pole design. Combining residual current (RCD) and overcurrent (MCB) protection in one device, it safeguards circuits against AC and pulsating DC faults. With a switched neutral built in, it guarantees full circuit isolation during a fault, ensuring safer maintenance and compliance with \u003cstrong\u003eBS 7671 (18th Edition)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e A 32A B-curve RCBO is often used for dedicated appliance circuits (such as cookers, showers, or small submains) where a higher load capacity is required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32A B-Curve RCBO:\u003c\/strong\u003e Suited to higher load domestic and light commercial circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A protection:\u003c\/strong\u003e Trips on AC and pulsating DC residual currents\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact single-module width:\u003c\/strong\u003e Saves space in distribution boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-pole switched neutral:\u003c\/strong\u003e Ensures full disconnection of live and neutral\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimises disruption:\u003c\/strong\u003e Only the faulty circuit is isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBS 7671 compliant:\u003c\/strong\u003e Meets Amendment 2 safety standards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55285565948280,"sku":"WRN32B-030","price":18.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRN20C.webp?v=1758639151"},{"product_id":"single-module-2-pole-rcbo-40a-b-curve-wrn40b-030","title":"Single Module 2 Pole RCBO 40A B Curve WRN40B-030","description":"\u003cp\u003eThe \u003cstrong\u003eWRN40B-030\u003c\/strong\u003e is a \u003cstrong\u003e40A Type A RCBO\u003c\/strong\u003e in a compact single-module, 2-pole design. It combines residual current (RCD) and overcurrent (MCB) protection in one device, detecting both AC and pulsating DC leakage faults. With a switched neutral built in, this RCBO fully isolates live and neutral conductors during a fault, helping installers meet \u003cstrong\u003eBS 7671 (18th Edition)\u003c\/strong\u003e compliance while keeping healthy circuits energised.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The 40A B-curve RCBO is often used for high-load subcircuits and small distribution boards where both overload and earth leakage protection must be combined into one device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A B-Curve RCBO:\u003c\/strong\u003e Suited to high-load domestic and commercial circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A protection:\u003c\/strong\u003e Trips on AC and pulsating DC residual currents\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact single-module design:\u003c\/strong\u003e Saves board space\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-pole with switched neutral:\u003c\/strong\u003e Disconnects both conductors during faults\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimises disruption:\u003c\/strong\u003e Isolates only the faulty circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18th Edition compliant:\u003c\/strong\u003e BS 7671 Amendment 2 ready\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55285569192312,"sku":"WRN40B-030","price":18.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRN20C.webp?v=1758639151"},{"product_id":"single-module-2-pole-rcbo-20a-b-curve-wrn20b-030","title":"Single Module 2 Pole RCBO 20A B Curve WRN20B-030","description":"\u003cp\u003eThe \u003cstrong\u003eWRN20B-030\u003c\/strong\u003e is a \u003cstrong\u003e20A Type A RCBO\u003c\/strong\u003e in a single-module, 2-pole design — providing both residual current (RCD) and overcurrent (MCB) protection in one compact device. It detects AC and pulsating DC leakage currents, making it suitable for modern domestic and commercial installations. With a built-in switched neutral, this RCBO ensures full circuit isolation on fault while keeping healthy circuits in service.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background:#f9f9f9; padding:12px; border-left:4px solid #ff6d02; margin:16px 0;\"\u003e\n  \u003cp style=\"margin:0; font-size:14px; color:#444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e For socket circuits and small appliance loads, a 20A B-Curve RCBO is often the most efficient choice. The WRN20B-030 covers both overload and residual current protection in one unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e20A B-Curve RCBO:\u003c\/strong\u003e Ideal for socket outlets, small power circuits, and domestic loads\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType A protection:\u003c\/strong\u003e Trips on AC and pulsating DC leakage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact:\u003c\/strong\u003e Single 18mm module width\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e2-pole switched neutral:\u003c\/strong\u003e Ensures complete disconnection on fault\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimises disruption:\u003c\/strong\u003e Only the faulty circuit is isolated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBS 7671 compliant:\u003c\/strong\u003e Meets 18th Edition Amendment 2 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55285569749368,"sku":"WRN20B-030","price":18.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRN20C.webp?v=1758639151"},{"product_id":"arc-fault-detection-a-type-rcbo-wfd110b-030","title":"Arc Fault Detection A-Type RCBO – WFD110B-030 (10A, B Curve, 30mA)","description":"\u003cp\u003eThe \u003cstrong\u003eWFD110B-030\u003c\/strong\u003e is a \u003cstrong\u003e10A, B Curve Arc Fault Detection (AFDD) RCBO\u003c\/strong\u003e, combining arc fault detection, residual current protection (30mA), short-circuit, and overload protection in one compact device. Built to \u003cstrong\u003eBS 7671:2018 (18th Edition)\u003c\/strong\u003e standards, it delivers advanced fire prevention for modern electrical systems.\u003c\/p\u003e\n\u003cp\u003eUnlike a standard \u003ca href=\"\/collections\/rcbos\"\u003eRCBO\u003c\/a\u003e, this device features microprocessor-based \u003cstrong\u003earc fault detection\u003c\/strong\u003e, continuously monitoring the electrical waveform for dangerous arc signals caused by \u003cstrong\u003eworn wiring, poor connections, ageing circuits, or faulty appliances\u003c\/strong\u003e. When detected, it trips instantly, cutting both live and neutral conductors to eliminate fire hazards.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The 10A AFDD RCBO is best suited for socket circuits and small appliance circuits in HMOs, student housing, and sleeping accommodation where fire prevention is essential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProtective Coverage\u003c\/h3\u003e\n\u003cp\u003eThis AFDD RCBO combines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc fault detection\u003c\/strong\u003e – series and parallel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual current protection\u003c\/strong\u003e – Type A (30mA, AC + pulsed DC)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eShort-circuit and overload protection\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage protection\u003c\/strong\u003e – trips at 275V ±5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSensitivity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd1-b-030\"\u003e\u003cstrong\u003eWFD106B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWFD110B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd116b-030\"\u003e\u003cstrong\u003eWFD116B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd120b-030\"\u003e\u003cstrong\u003eWFD120B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd132b-030\"\u003e\u003cstrong\u003eWFD132B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd140b-030\"\u003e\u003cstrong\u003eWFD140B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288500388216,"sku":"WFD110B-030","price":96.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WFD132C-030.png?v=1750259288"},{"product_id":"arc-fault-detection-a-type-rcbo-wfd116b-030","title":"Arc Fault Detection A-Type RCBO – WFD116B-030 (16A, B Curve, 30mA)","description":"\u003cp\u003eThe \u003cstrong\u003eWFD116B-030\u003c\/strong\u003e is a \u003cstrong\u003e16A, B Curve Arc Fault Detection (AFDD) RCBO\u003c\/strong\u003e, providing arc fault detection, residual current protection (30mA), short-circuit, and overload protection in one device. Designed to \u003cstrong\u003eBS 7671:2018 (18th Edition)\u003c\/strong\u003e standards, it offers advanced fire prevention and peace of mind for installers and property owners.\u003c\/p\u003e\n\u003cp\u003eUnlike standard \u003ca href=\"\/collections\/rcbos\"\u003eRCBOs\u003c\/a\u003e, this AFDD RCBO includes a microprocessor-driven arc detection system. It monitors the electrical waveform and trips instantly when dangerous arc impulses occur, caused by \u003cstrong\u003edamaged cables, loose terminations, faulty appliances, or ageing wiring\u003c\/strong\u003e. Both live and neutral poles are disconnected, ensuring complete circuit isolation.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The 16A version is well-suited to kitchen ring circuits, small power circuits, and areas with higher load appliances where fire protection is a must.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProtective Coverage\u003c\/h3\u003e\n\u003cp\u003eThis AFDD RCBO protects against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc faults\u003c\/strong\u003e – series and parallel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual current leakage\u003c\/strong\u003e – Type A (AC + pulsed DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload and short-circuit\u003c\/strong\u003e conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage\u003c\/strong\u003e – trips at 275V ±5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSensitivity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd1-b-030\"\u003e\u003cstrong\u003eWFD106B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd110b-030\"\u003e\u003cstrong\u003eWFD110B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWFD116B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd120b-030\"\u003e\u003cstrong\u003eWFD120B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd132b-030\"\u003e\u003cstrong\u003eWFD132B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd140b-030\"\u003e\u003cstrong\u003eWFD140B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288500715896,"sku":"WFD116B-030","price":96.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WFD132C-030.png?v=1750259288"},{"product_id":"arc-fault-detection-a-type-rcbo-wfd120b-030","title":"Arc Fault Detection A-Type RCBO – WFD120B-030 (20A, B Curve, 30mA)","description":"\u003cp\u003eThe \u003cstrong\u003eWFD120B-030\u003c\/strong\u003e is a \u003cstrong\u003e20A, B Curve Arc Fault Detection (AFDD) RCBO\u003c\/strong\u003e, combining arc fault detection, 30mA Type A residual current protection, short-circuit, and overload protection in a single compact unit. Fully compliant with \u003cstrong\u003eBS 7671:2018 (18th Edition)\u003c\/strong\u003e, it provides advanced fire prevention for modern electrical systems.\u003c\/p\u003e\n\u003cp\u003eUnlike conventional \u003ca href=\"\/collections\/rcbos\"\u003eRCBOs\u003c\/a\u003e, this AFDD RCBO includes a microprocessor-based detection system that identifies arc faults caused by \u003cstrong\u003edamaged conductors, loose connections, or faulty appliances\u003c\/strong\u003e. Once detected, the device trips instantly and isolates both live and neutral poles, ensuring maximum safety.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The 20A AFDD RCBO is ideal for circuits supplying socket outlets, kitchen appliances, and small commercial installs where fire risk is high.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProtective Coverage\u003c\/h3\u003e\n\u003cp\u003eThe WFD120B-030 combines the functionality of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc Fault Detection\u003c\/strong\u003e – protects against series and parallel faults\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Protection\u003c\/strong\u003e – Type A, 30mA (AC and pulsed DC leakage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e – short-circuit and overload\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e – trips at 275V ±5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSensitivity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd1-b-030\"\u003e\u003cstrong\u003eWFD106B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd110b-030\"\u003e\u003cstrong\u003eWFD110B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd116b-030\"\u003e\u003cstrong\u003eWFD116B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWFD120B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd132b-030\"\u003e\u003cstrong\u003eWFD132B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd140b-030\"\u003e\u003cstrong\u003eWFD140B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288500978040,"sku":"WFD120B-030","price":96.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WFD132C-030.png?v=1750259288"},{"product_id":"arc-fault-detection-a-type-rcbo-wfd132b-030","title":"Arc Fault Detection A-Type RCBO – WFD132B-030 (32A, B Curve, 30mA)","description":"\u003cp\u003eThe \u003cstrong\u003eWFD132B-030\u003c\/strong\u003e is a \u003cstrong\u003e32A, B Curve Arc Fault Detection (AFDD) RCBO\u003c\/strong\u003e, combining arc fault detection, 30mA Type A residual current protection, short-circuit, and overload protection in one compact unit. Fully compliant with \u003cstrong\u003eBS 7671:2018 (18th Edition)\u003c\/strong\u003e, it offers a reliable fire-safe solution for demanding circuits.\u003c\/p\u003e\n\u003cp\u003eUnlike standard \u003ca href=\"\/collections\/rcbos\"\u003eRCBOs\u003c\/a\u003e, this AFDD model features advanced microprocessor-driven arc detection technology. It continuously analyses waveforms and trips when \u003cstrong\u003eworn insulation, loose terminals, or appliance faults\u003c\/strong\u003e generate dangerous arcs. Both live and neutral conductors are isolated instantly for maximum circuit safety.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The 32A AFDD RCBO is suited for high-demand appliance circuits, small distribution setups, and final circuits supplying sockets in commercial or rental properties.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProtective Coverage\u003c\/h3\u003e\n\u003cp\u003eThis AFDD RCBO offers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc fault detection\u003c\/strong\u003e – both series and parallel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual current protection\u003c\/strong\u003e – Type A, 30mA (AC + pulsed DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent protection\u003c\/strong\u003e – overload and short-circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage protection\u003c\/strong\u003e – trips at 275V ±5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSensitivity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd1-b-030\"\u003e\u003cstrong\u003eWFD106B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd110b-030\"\u003e\u003cstrong\u003eWFD110B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd116b-030\"\u003e\u003cstrong\u003eWFD116B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd120b-030\"\u003e\u003cstrong\u003eWFD120B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWFD132B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd140b-030\"\u003e\u003cstrong\u003eWFD140B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288501207416,"sku":"WFD132B-030","price":96.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WFD132C-030.png?v=1750259288"},{"product_id":"arc-fault-detection-a-type-rcbo-wfd140b-030","title":"Arc Fault Detection A-Type RCBO – WFD140B-030 (40A, B Curve, 30mA)","description":"\u003cp\u003eThe \u003cstrong\u003eWFD140B-030\u003c\/strong\u003e is a \u003cstrong\u003e40A, B Curve Arc Fault Detection (AFDD) RCBO\u003c\/strong\u003e, designed to deliver maximum protection against arc faults, earth leakage, overload, and short circuits in one compact unit. Built to \u003cstrong\u003eBS 7671:2018 (18th Edition)\u003c\/strong\u003e standards, it provides fire-safe reliability for high-load domestic and commercial circuits.\u003c\/p\u003e\n\u003cp\u003eUnlike a standard \u003ca href=\"\/collections\/rcbos\"\u003eRCBO\u003c\/a\u003e, this device features microprocessor-driven \u003cstrong\u003earc fault detection\u003c\/strong\u003e that constantly monitors electrical waveforms. It trips instantly when dangerous arcs occur due to \u003cstrong\u003edamaged insulation, loose terminals, or faulty appliances\u003c\/strong\u003e. Both live and neutral poles are isolated for complete safety.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The 40A AFDD RCBO is suited to high-demand circuits in commercial buildings, HMOs, and rental properties where enhanced fire safety is critical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProtective Coverage\u003c\/h3\u003e\n\u003cp\u003eThis AFDD RCBO combines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc Fault Detection\u003c\/strong\u003e – both series and parallel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Protection\u003c\/strong\u003e – Type A, 30mA (AC + pulsed DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e – overload and short-circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e – trips at 275V ±5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVariant Comparison\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSensitivity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd1-b-030\"\u003e\u003cstrong\u003eWFD106B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd110b-030\"\u003e\u003cstrong\u003eWFD110B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd116b-030\"\u003e\u003cstrong\u003eWFD116B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd120b-030\"\u003e\u003cstrong\u003eWFD120B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/arc-fault-detection-a-type-rcbo-wfd132b-030\"\u003e\u003cstrong\u003eWFD132B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWFD140B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288501502328,"sku":"WFD140B-030","price":96.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WFD132C-030.png?v=1750259288"},{"product_id":"a-type-mini-rcbo-10a-b-curve-high-immunity","title":"High Immunity Type A Mini RCBO – 10A B Curve (WRB110B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWRB110B-030 High Immunity Type A Mini RCBO\u003c\/strong\u003e is a compact \u003cstrong\u003e10A B Curve protective device\u003c\/strong\u003e designed for domestic and commercial boards where space is limited. At just 18mm wide, it combines residual current and overcurrent protection in one module. With \u003cstrong\u003e30mA Type A sensitivity\u003c\/strong\u003e, it detects AC and pulsating DC leakage currents – keeping circuits compliant with 18th Edition regulations, including \u003ca href=\"\/collections\/ev-kits\"\u003eEV chargers\u003c\/a\u003e and \u003ca href=\"\/collections\/heat-pump-boards\"\u003erenewable installs\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the 10A B Curve for socket circuits or small appliance loads. For higher inrush current circuits, compare with the \u003ca href=\"\/products\/a-type-mini-rcbo-10a-c-curve-high-immunity\"\u003e10A C Curve version\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10A rated current\u003c\/strong\u003e – ideal for sockets and small appliance loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e – designed for general residential use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A sensitivity\u003c\/strong\u003e – detects AC + pulsating DC leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – reduces nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 18mm width\u003c\/strong\u003e – frees up ways in consumer units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – ensures full circuit isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e – suitable for PV and EV installs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare Mini RCBO Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWidth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRB110B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/a-type-mini-rcbo-10a-c-curve-high-immunity\"\u003e\u003cstrong\u003eWRB110C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288580079992,"sku":"WRB110B-030","price":11.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRB110B-030.png?v=1750260152"},{"product_id":"a-type-mini-rcbo-40a-b-curve-high-immunity","title":"High Immunity Type A Mini RCBO – 40A B Curve (WRB140B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWRB140B-030 High Immunity Type A Mini RCBO\u003c\/strong\u003e is a \u003cstrong\u003e40A B Curve protective device\u003c\/strong\u003e for residential and commercial circuits requiring higher current handling. At just 18mm wide, it combines overload, short-circuit, and residual current protection in a single compact module. With \u003cstrong\u003e30mA Type A sensitivity\u003c\/strong\u003e and a high-immunity build, it ensures safe and stable protection for \u003ca href=\"\/collections\/ev-kits\"\u003eEV chargers\u003c\/a\u003e, socket outlets, and fixed appliance circuits in line with 18th Edition standards.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the 40A B Curve for higher-load socket or appliance circuits. If protecting motors or equipment with higher inrush currents, use the \u003ca href=\"\/products\/a-type-mini-rcbo-40a-c-curve-high-immunity\"\u003e40A C Curve variant\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A rated current\u003c\/strong\u003e – protects larger socket and appliance circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB Curve tripping\u003c\/strong\u003e – suited to residential and light commercial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A sensitivity\u003c\/strong\u003e – detects AC + pulsating DC leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – minimises false tripping under harmonics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 18mm module\u003c\/strong\u003e – ideal for retrofit boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – ensures complete isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e – safe for EV and PV installs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare Mini RCBO Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWidth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRB140B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/a-type-mini-rcbo-40a-c-curve-high-immunity\"\u003e\u003cstrong\u003eWRB140C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288605704568,"sku":"WRB140B-030","price":11.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRB110B-030.png?v=1750260152"},{"product_id":"a-type-mini-rcbo-32a-b-curve-high-immunity","title":"High Immunity Type A Mini RCBO – 32A B Curve (WRB132B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWRB132B-030 High Immunity Type A Mini RCBO\u003c\/strong\u003e is a \u003cstrong\u003e32A B Curve protective device\u003c\/strong\u003e designed for medium-load circuits in residential and light commercial installs. Its slim 18mm design combines short-circuit, overload, and residual current protection in one unit. With \u003cstrong\u003e30mA Type A sensitivity\u003c\/strong\u003e and high immunity, it ensures safe, stable protection on \u003ca href=\"\/collections\/ev-kits\"\u003eEV chargers\u003c\/a\u003e, socket circuits, and fixed appliances in compliance with the 18th Edition.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the 32A B Curve for general-purpose socket or appliance circuits requiring higher current handling. For motor-driven or inrush-heavy loads, use the \u003ca href=\"\/products\/a-type-mini-rcbo-32a-c-curve-high-immunity\"\u003e32A C Curve variant\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32A rated current\u003c\/strong\u003e – protects larger socket or appliance circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB Curve tripping\u003c\/strong\u003e – designed for standard residential and light commercial loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A sensitivity\u003c\/strong\u003e – detects AC + pulsating DC leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity\u003c\/strong\u003e – reduces nuisance tripping under harmonics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 18mm module\u003c\/strong\u003e – space saving for retrofit boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – ensures full isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e – suitable for PV and EV installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare Mini RCBO Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWidth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRB132B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/a-type-mini-rcbo-32a-c-curve-high-immunity\"\u003e\u003cstrong\u003eWRB132C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288605933944,"sku":"WRB132B-030","price":11.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRB110B-030.png?v=1750260152"},{"product_id":"a-type-mini-rcbo-20a-b-curve-high-immunity","title":"High Immunity Type A Mini RCBO – 20A B Curve (WRB120B-030)","description":"\u003cp\u003e\u003cstrong\u003eWRB120B-030\u003c\/strong\u003e is a \u003cstrong\u003e20A B Curve high immunity Type A mini RCBO\u003c\/strong\u003e designed for general-purpose domestic and commercial circuits. It combines overload, short-circuit, and residual current protection in one compact single-module device, making it ideal where board space is limited.\u003c\/p\u003e\n\n\u003cp\u003eAs part of the Whitecliffe WRB range, this RCBO provides \u003cstrong\u003eType A protection\u003c\/strong\u003e, detecting standard AC faults and \u003cstrong\u003epulsating DC components\u003c\/strong\u003e. The \u003cstrong\u003ehigh immunity design\u003c\/strong\u003e helps reduce nuisance tripping, while the built-in \u003cstrong\u003eswitched neutral\u003c\/strong\u003e provides full isolation of live and neutral conductors on a faulty circuit.\u003c\/p\u003e\n\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the 20A B Curve for general-purpose socket and small appliance circuits. Where the circuit has higher startup or inrush demand, a \u003ca href=\"\/products\/a-type-mini-rcbo-20a-c-curve-high-immunity\"\u003e20A C Curve variant\u003c\/a\u003e may be more suitable.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20A rated current\u003c\/strong\u003e – suited to general-purpose circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB Curve tripping\u003c\/strong\u003e – suitable for standard domestic and commercial loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A protection\u003c\/strong\u003e – detects AC and pulsating DC components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – helps reduce nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e30mA residual current protection\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e6kA breaking capacity\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1P+N format\u003c\/strong\u003e – switched live and neutral\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 18mm width\u003c\/strong\u003e – saves space in the board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional operation\u003c\/strong\u003e – suitable for modern PV and EV system layouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare Mini RCBO Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWidth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRB120B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/a-type-mini-rcbo-20a-c-curve-high-immunity\"\u003e\u003cstrong\u003eWRB120C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288607244664,"sku":"WRB120B-030","price":11.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRB110B-030.png?v=1750260152"},{"product_id":"a-type-mini-rcbo-16a-b-curve-high-immunity","title":"High Immunity Type A Mini RCBO – 16A B Curve (WRB116B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWRB116B-030 High Immunity Type A Mini RCBO\u003c\/strong\u003e is a \u003cstrong\u003e16A B Curve device\u003c\/strong\u003e designed to protect small power and lighting circuits while saving space in the board. At just 18mm wide, it combines residual current and overcurrent protection in one compact module. With \u003cstrong\u003e30mA Type A sensitivity\u003c\/strong\u003e and high immunity design, it delivers reliable protection against AC and pulsating DC leakage currents in compliance with the 18th Edition regulations.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the 16A B Curve for radial socket circuits, lighting banks, or small fixed appliances. For circuits with motors or higher inrush currents, see the \u003ca href=\"\/products\/a-type-mini-rcbo-16a-c-curve-high-immunity\"\u003e16A C Curve variant\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16A rated current\u003c\/strong\u003e – suitable for small power and lighting circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB Curve tripping\u003c\/strong\u003e – designed for standard residential and light commercial loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A sensitivity\u003c\/strong\u003e – detects AC + pulsating DC leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity\u003c\/strong\u003e – reduces nuisance tripping under harmonic-rich conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-module width (18mm)\u003c\/strong\u003e – saves space inside the board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – isolates both conductors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e – safe for use with PV and EV installs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare Mini RCBO Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWidth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRB116B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/a-type-mini-rcbo-16a-c-curve-high-immunity\"\u003e\u003cstrong\u003eWRB116C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288608162168,"sku":"WRB116B-030","price":11.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRB110B-030.png?v=1750260152"},{"product_id":"a-type-mini-rcbo-6a-b-curve-high-immunity","title":"High Immunity Type A Mini RCBO – 6A B Curve (WRB106B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWRB106B-030 High Immunity Type A Mini RCBO\u003c\/strong\u003e is a compact \u003cstrong\u003e6A B Curve device\u003c\/strong\u003e that combines residual current and overcurrent protection in a single 18mm module. Designed for boards where space is limited, it provides \u003cstrong\u003e30mA Type A protection\u003c\/strong\u003e, detecting AC and pulsating DC leakage currents to ensure compliance with 18th Edition regulations.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Choose the 6A B Curve version for lighting and small domestic loads. If you’re working on circuits with higher inrush currents, switch to the \u003ca href=\"\/products\/a-type-mini-rcbo-6a-c-curve-high-immunity\"\u003e6A C Curve variant\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6A rated current\u003c\/strong\u003e – ideal for lighting and small domestic circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e – suited to standard residential loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A sensitivity\u003c\/strong\u003e – detects AC + pulsating DC leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – minimises nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-module width (18mm)\u003c\/strong\u003e – saves space in consumer units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – provides full isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e – safe for use with PV and EV systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare Mini RCBO Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWidth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRB106B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/a-type-mini-rcbo-6a-c-curve-high-immunity\"\u003e\u003cstrong\u003eWRB106B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288609177976,"sku":"WRB106B-030","price":11.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRB110B-030.png?v=1750260152"},{"product_id":"a-type-mini-rcbo-25a-b-curve-high-immunity","title":"High Immunity Type A Mini RCBO – 25A B Curve (WRB125B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWRB125B-030 High Immunity Type A Mini RCBO\u003c\/strong\u003e is a \u003cstrong\u003e25A B Curve protective device\u003c\/strong\u003e that combines overload, short-circuit, and residual current protection in a single compact unit. At just 18mm wide, it’s ideal for space-limited boards in residential or light commercial installs. With \u003cstrong\u003e30mA Type A sensitivity\u003c\/strong\u003e and high immunity against nuisance tripping, it ensures safe operation on socket, appliance, and lighting circuits in line with 18th Edition standards.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the 25A B Curve for small power circuits and appliances where a 25A rating is required. For inrush-heavy circuits, choose the \u003ca href=\"\/products\/a-type-mini-rcbo-25a-c-curve-high-immunity\"\u003e25A C Curve variant\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e25A rated current\u003c\/strong\u003e – protects medium-load circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB Curve tripping\u003c\/strong\u003e – suited for standard residential and light commercial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A sensitivity\u003c\/strong\u003e – detects AC + pulsating DC leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – reduces false tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 18mm width\u003c\/strong\u003e – ideal for retrofit and consumer unit upgrades\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – full circuit isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e – suitable for PV and EV systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare Mini RCBO Variants\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWidth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRB125B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/a-type-mini-rcbo-25a-c-curve-high-immunity\"\u003e\u003cstrong\u003eWRB125C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eType A, High Immunity\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55288611996024,"sku":"WRB125B-030","price":11.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRB110B-030.png?v=1750260152"},{"product_id":"type-a-rcbo-16a-b-curve-30ma-wrt116b-030","title":"Type A RCBO – 16A B Curve, 30mA","description":"\u003cp\u003eThe \u003cstrong\u003eWRT116B-030\u003c\/strong\u003e is a \u003cstrong\u003e16A B Curve Type A RCBO\u003c\/strong\u003e combining \u003cstrong\u003eresidual current and overcurrent protection\u003c\/strong\u003e in one compact device. It features \u003cstrong\u003eswitched live and neutral disconnection\u003c\/strong\u003e for full isolation, a \u003cstrong\u003ehigh immunity design\u003c\/strong\u003e to reduce nuisance tripping, and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e for use in \u003cstrong\u003esolar PV, EV charging, and inverter-fed circuits\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eDesigned to detect both AC and pulsating DC leakage currents, it ensures compliance with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e. The slim 18mm module width allows direct installation into consumer units and distribution boards without wasted space.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Select the \u003cstrong\u003eB Curve\u003c\/strong\u003e for lighting and general-purpose socket circuits with low inrush currents. For EV chargers, motors, or heat pumps, use the C Curve version instead.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16A B Curve Type A RCBO\u003c\/strong\u003e – 30mA residual + overload protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – full fault isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity\u003c\/strong\u003e – prevents nuisance trips from harmonics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – suitable for inverter-fed systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact single-module\u003c\/strong\u003e – fits 18mm DIN rail slots\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – resilient for domestic \u0026amp; light commercial installs\u003c\/li\u003e\n\u003cli\u003eTested to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare WRT Range\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-6a-b-curve-30ma-wrt106b-030\"\u003e\u003cstrong\u003eWRT106B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eLighting \/ Small Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT116B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eGeneral Domestic Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-16a-c-curve-30ma-wrt116c-030\"\u003e\u003cstrong\u003eWRT116C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eEV \/ Heat Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-20a-b-curve-30ma-wrt120b-030\"\u003e\u003cstrong\u003eWRT120B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eLight Commercial \/ Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295774720376,"sku":"WRT116B-030","price":14.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT116B-030.png?v=1754319758"},{"product_id":"type-a-rcbo-20a-b-curve-30ma-wrt120b-030","title":"Type A RCBO – 20A B Curve, 30mA","description":"\u003cp\u003eThe \u003cstrong\u003eWRT120B-030\u003c\/strong\u003e is a \u003cstrong\u003e20A B Curve Type A RCBO\u003c\/strong\u003e that combines \u003cstrong\u003eovercurrent and residual current protection\u003c\/strong\u003e in a single compact device. Featuring \u003cstrong\u003eswitched live and neutral disconnection\u003c\/strong\u003e for full isolation, \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e for solar and EV applications, and a \u003cstrong\u003ehigh immunity design\u003c\/strong\u003e to minimise nuisance tripping, it’s a versatile choice for \u003cstrong\u003edomestic and light commercial installs\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis RCBO detects both AC faults and pulsating DC leakage currents, ensuring compliance with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e. Its slim, single-module profile makes it ideal for consumer units where space is limited.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The \u003cstrong\u003eB Curve\u003c\/strong\u003e is suited for general lighting and socket circuits with low inrush current. For motors, EV chargers, or heat pumps, use the C Curve model instead.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20A B Curve Type A RCBO\u003c\/strong\u003e – overload + earth leakage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – safe isolation of faulty circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – prevents nuisance trips in noisy environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – compatible with solar PV and inverter-fed systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 18mm module\u003c\/strong\u003e – saves space in consumer units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – reliable for residential and commercial use\u003c\/li\u003e\n\u003cli\u003eConforms to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare WRT Range\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-16a-b-curve-30ma-wrt116b-030\"\u003e\u003cstrong\u003eWRT116B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eDomestic \/ General Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT120B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eDomestic \/ Light Commercial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-20a-c-curve-30ma-wrt120c-030\"\u003e\u003cstrong\u003eWRT120C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eMotors \/ EV \/ Heat Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-25a-b-curve-30ma-wrt125b-030\"\u003e\u003cstrong\u003eWRT125B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eHigher Load Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295777505656,"sku":"WRT120B-030","price":14.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT116B-030.png?v=1754319758"},{"product_id":"type-a-rcbo-25a-b-curve-30ma-wrt125b-030","title":"Type A RCBO – 25A B Curve, 30mA","description":"\u003cp\u003eThe \u003cstrong\u003eWRT125B-030\u003c\/strong\u003e is a \u003cstrong\u003e25A B Curve Type A RCBO\u003c\/strong\u003e combining \u003cstrong\u003eresidual current and overcurrent protection\u003c\/strong\u003e in one slim device. It features \u003cstrong\u003eswitched live and neutral disconnection\u003c\/strong\u003e for safe isolation, \u003cstrong\u003ehigh immunity electronics\u003c\/strong\u003e to reduce nuisance trips, and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e suitable for \u003cstrong\u003esolar PV, EV chargers, and inverter-fed systems\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eTested to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e, this RCBO meets the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e and fits directly into standard 18mm DIN rail consumer units, making it a reliable choice for both \u003cstrong\u003edomestic and light commercial installs\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The \u003cstrong\u003eB Curve\u003c\/strong\u003e is best for socket circuits and domestic loads with low inrush current. For motors, EV chargers, or circuits with higher start-up loads, select the C Curve version.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e25A B Curve Type A RCBO\u003c\/strong\u003e – overload and 30mA residual protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – isolates both conductors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – resists false trips in noisy environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – inverter and solar compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 18mm module\u003c\/strong\u003e – saves space in consumer units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – robust for domestic \u0026amp; light commercial boards\u003c\/li\u003e\n\u003cli\u003eConforms to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare WRT Range\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-20a-b-curve-30ma-wrt120b-030\"\u003e\u003cstrong\u003eWRT120B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eDomestic \/ Light Commercial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT125B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eHigher Load Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-25a-c-curve-30ma-wrt125c-030\"\u003e\u003cstrong\u003eWRT125C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eMotors \/ EV \/ Heat Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-32a-b-curve-30ma-wrt132b-030\"\u003e\u003cstrong\u003eWRT132B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eGeneral Loads \/ Consumer Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295779537272,"sku":"WRT125B-030","price":14.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT116B-030.png?v=1754319758"},{"product_id":"type-a-rcbo-32a-b-curve-30ma-wrt132b-030","title":"Type A RCBO – 32A B Curve, 30mA","description":"\u003cp\u003eThe \u003cstrong\u003eWRT132B-030\u003c\/strong\u003e is a \u003cstrong\u003e32A B Curve Type A RCBO\u003c\/strong\u003e that delivers \u003cstrong\u003eovercurrent and 30mA residual current protection\u003c\/strong\u003e in one slimline device. It features \u003cstrong\u003eswitched live and neutral isolation\u003c\/strong\u003e for safe disconnection, a \u003cstrong\u003ehigh immunity design\u003c\/strong\u003e to reduce nuisance trips, and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e that makes it suitable for \u003cstrong\u003esolar PV, EV charging, and inverter-based circuits\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eBuilt to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e standards, this RCBO is fully compliant with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e and can be installed in standard 18mm DIN rail consumer units for domestic and commercial projects.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the \u003cstrong\u003eB Curve\u003c\/strong\u003e for domestic socket and lighting circuits where inrush currents are low. For EV chargers, motors, or heat pumps, select the C Curve version instead.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32A B Curve Type A RCBO\u003c\/strong\u003e – combined overload + residual current protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – disconnects both poles safely\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity\u003c\/strong\u003e – reduces false tripping in noisy circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – inverter and solar ready\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 18mm module\u003c\/strong\u003e – easy consumer unit fit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – durable for residential \u0026amp; light commercial\u003c\/li\u003e\n\u003cli\u003eMeets \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare WRT Range\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-25a-b-curve-30ma-wrt125b-030\"\u003e\u003cstrong\u003eWRT125B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eHigher Load Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT132B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eConsumer Units \/ General Loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-32a-c-curve-30ma-wrt132c-030\"\u003e\u003cstrong\u003eWRT132C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eMotors \/ EV \/ Inrush Loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-40a-b-curve-30ma-wrt140b-030\"\u003e\u003cstrong\u003eWRT140B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eDomestic \/ Commercial Loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295779864952,"sku":"WRT132B-030","price":14.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT116B-030.png?v=1754319758"},{"product_id":"type-a-rcbo-40a-b-curve-30ma-wrt140b-030","title":"Type A RCBO – 40A B Curve, 30mA","description":"\u003cp\u003eThe \u003cstrong\u003eWRT140B-030\u003c\/strong\u003e is a \u003cstrong\u003e40A B Curve Type A RCBO\u003c\/strong\u003e that delivers \u003cstrong\u003eovercurrent and 30mA residual current protection\u003c\/strong\u003e in one compact device. Featuring \u003cstrong\u003eswitched live and neutral disconnection\u003c\/strong\u003e for full circuit isolation, \u003cstrong\u003ehigh immunity electronics\u003c\/strong\u003e to resist nuisance tripping, and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e for flexible use in \u003cstrong\u003esolar PV, EV charging, and inverter-fed systems\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eFully compliant with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e and tested to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e, this RCBO is a robust solution for \u003cstrong\u003edomestic and commercial circuits\u003c\/strong\u003e requiring 40A protection.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the \u003cstrong\u003eB Curve\u003c\/strong\u003e for general lighting and socket circuits with low inrush current. For EV chargers, heat pumps, and motors with higher start-up demand, select the C Curve version.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A B Curve Type A RCBO\u003c\/strong\u003e – overload + residual current protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – safe fault isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – resists nuisance trips from harmonics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – ideal for inverter-fed and renewable systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 18mm module\u003c\/strong\u003e – fits standard consumer units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – built for domestic \u0026amp; commercial installs\u003c\/li\u003e\n\u003cli\u003eConforms to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare WRT Range\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-32a-b-curve-30ma-wrt132b-030\"\u003e\u003cstrong\u003eWRT132B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eConsumer Units \/ General Loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT140B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eDomestic \/ Commercial Loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-40a-c-curve-30ma-wrt140c-030\"\u003e\u003cstrong\u003eWRT140C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eEV \/ Motors \/ Heat Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-50a-b-curve-30ma-wrt150b-030\"\u003e\u003cstrong\u003eWRT150B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eHigher Load Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295780389240,"sku":"WRT140B-030","price":14.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT116B-030.png?v=1754319758"},{"product_id":"type-a-rcbo-50a-b-curve-30ma-wrt150b-030","title":"Type A RCBO – 50A B Curve, 30mA","description":"\u003cp\u003eThe \u003cstrong\u003eWRT150B-030\u003c\/strong\u003e is a \u003cstrong\u003e50A B Curve Type A RCBO\u003c\/strong\u003e designed for \u003cstrong\u003ehigh load domestic and commercial circuits\u003c\/strong\u003e. It combines \u003cstrong\u003eovercurrent and 30mA residual current protection\u003c\/strong\u003e in a compact single-module device, with \u003cstrong\u003eswitched live and neutral disconnection\u003c\/strong\u003e for full isolation and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e for \u003cstrong\u003esolar PV, EV, and inverter-fed systems\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eWith \u003cstrong\u003ehigh immunity electronics\u003c\/strong\u003e to minimise nuisance trips, this RCBO ensures compliance with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e and is tested to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e standards for safety and durability.\u003c\/p\u003e\n\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the \u003cstrong\u003eB Curve\u003c\/strong\u003e for heavy-duty circuits where low inrush currents are expected. For EV, motors, or equipment with high inrush demand, select the C Curve version.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e50A B Curve Type A RCBO\u003c\/strong\u003e – overload + earth leakage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – full disconnection of both conductors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – prevents nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – ideal for inverter and renewable circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact single-module\u003c\/strong\u003e – 18mm DIN rail fit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – robust for high load installs\u003c\/li\u003e\n\u003cli\u003eConforms to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare WRT Range\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-40a-b-curve-30ma-wrt140b-030\"\u003e\u003cstrong\u003eWRT140B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eDomestic \/ Commercial Loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT150B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eHigh Load Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-50a-c-curve-30ma-wrt150c-030\"\u003e\u003cstrong\u003eWRT150C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eEV \/ Motors \/ Inrush Loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295780979064,"sku":"WRT150B-030","price":14.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT116B-030.png?v=1754319758"},{"product_id":"high-immunity-type-a-rcbo-32a-b-curve-30ma-wer32b-030","title":"High Immunity RCBO – 32A B Curve, Type A, 30mA (WER32B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWER32B-030\u003c\/strong\u003e is a \u003cstrong\u003e32A B Curve High Immunity Type A RCBO\u003c\/strong\u003e, engineered for \u003cstrong\u003esolar PV, battery storage, and EV-ready consumer units\u003c\/strong\u003e. It provides combined \u003cstrong\u003eoverload, short-circuit, and 30mA residual current protection\u003c\/strong\u003e with added immunity against nuisance tripping in inverter-heavy environments.\u003c\/p\u003e\n\u003cp\u003eBuilt with \u003cstrong\u003edouble pole disconnection\u003c\/strong\u003e and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e, this RCBO ensures safe, compliant installs in line with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The \u003cstrong\u003eB Curve\u003c\/strong\u003e profile is intended for general domestic and commercial loads with low inrush current. For EV chargers, motors, or heat pumps, the C Curve version is a better fit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32A B Curve Type A RCBO\u003c\/strong\u003e – overload + earth leakage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – resists false trips from harmonics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30mA sensitivity\u003c\/strong\u003e – regulation compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – durable for residential and commercial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble pole disconnection\u003c\/strong\u003e – isolates both live + neutral\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – line\/load reversible\u003c\/li\u003e\n\u003cli\u003eMeets \u003cstrong\u003eBS EN 61009\u003c\/strong\u003e and \u003cstrong\u003e18th Edition Amendment 2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare High Immunity RCBOs\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06b\"\u003e\u003cstrong\u003eWER06B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eLighting and other low inrush final circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06c\"\u003e\u003cstrong\u003eWER06C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLow-rated circuits where higher inrush tolerance is preferred\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-b-curve-30ma-wer16b-030\"\u003e\u003cstrong\u003eWER16B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eGeneral domestic final circuits with low inrush loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-c-curve-30ma-wer16c-030\"\u003e\u003cstrong\u003eWER16C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eSmall motors and circuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-b-curve-30ma-wer20b-030\"\u003e\u003cstrong\u003eWER20B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eDomestic final circuits requiring a higher current rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-c-curve-30ma-wer20c-030\"\u003e\u003cstrong\u003eWER20C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eCircuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWER32B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eRing finals and other standard appliance circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-c-curve-30ma-wer32c-030\"\u003e\u003cstrong\u003eWER32C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHigher demand circuits and loads with greater inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-b-curve-30ma-wer40b-030\"\u003e\u003cstrong\u003eWER40B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eHigher load circuits with lower inrush characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-c-curve-30ma-wer40c-030\"\u003e\u003cstrong\u003eWER40C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHeavier-duty circuits with higher inrush conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-63a-c-curve-type-a-30ma\"\u003e\u003cstrong\u003eWER63C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLarger commercial or high-load applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295844516216,"sku":"WER32B-030","price":19.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WER40B-030.png?v=1760363829"},{"product_id":"high-immunity-type-a-rcbo-40a-b-curve-30ma-wer40b-030","title":"High Immunity RCBO – 40A B Curve, Type A, 30mA (WER40B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWER40B-030\u003c\/strong\u003e is a \u003cstrong\u003e40A B Curve High Immunity Type A RCBO\u003c\/strong\u003e designed for heavier duty residential and commercial circuits, including \u003cstrong\u003esolar PV, battery storage, and EV-ready consumer units\u003c\/strong\u003e. It combines \u003cstrong\u003eoverload, short-circuit, and 30mA residual current protection\u003c\/strong\u003e with enhanced resistance to nuisance tripping caused by harmonics or transient voltages.\u003c\/p\u003e\n\u003cp\u003eWith \u003cstrong\u003edouble pole disconnection\u003c\/strong\u003e and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e, this RCBO provides full compliance with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e and safe operation in inverter-fed systems.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e The \u003cstrong\u003eB Curve\u003c\/strong\u003e is suited for standard circuits with lower inrush currents. For EV chargers, motors, or heat pumps, use the \u003cstrong\u003eC Curve\u003c\/strong\u003e version of this device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40A B Curve Type A RCBO\u003c\/strong\u003e – protects against overload and earth leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity electronics\u003c\/strong\u003e – resists nuisance trips\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30mA sensitivity\u003c\/strong\u003e – compliant with Amendment 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – built for residential \u0026amp; commercial installs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble pole disconnection\u003c\/strong\u003e – isolates live + neutral conductors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – install either way round\u003c\/li\u003e\n\u003cli\u003eMeets \u003cstrong\u003eBS EN 61009\u003c\/strong\u003e \u0026amp; \u003cstrong\u003e18th Edition Wiring Regulations\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare High Immunity RCBOs\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06b\"\u003e\u003cstrong\u003eWER06B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eLighting and other low inrush final circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06c\"\u003e\u003cstrong\u003eWER06C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLow-rated circuits where higher inrush tolerance is preferred\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-b-curve-30ma-wer16b-030\"\u003e\u003cstrong\u003eWER16B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eGeneral domestic final circuits with low inrush loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-c-curve-30ma-wer16c-030\"\u003e\u003cstrong\u003eWER16C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eSmall motors and circuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-b-curve-30ma-wer20b-030\"\u003e\u003cstrong\u003eWER20B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eDomestic final circuits requiring a higher current rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-c-curve-30ma-wer20c-030\"\u003e\u003cstrong\u003eWER20C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eCircuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-b-curve-30ma-wer32b-030\"\u003e\u003cstrong\u003eWER32B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eRing finals and other standard appliance circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-c-curve-30ma-wer32c-030\"\u003e\u003cstrong\u003eWER32C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHigher demand circuits and loads with greater inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWER40B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eHigher load circuits with lower inrush characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-c-curve-30ma-wer40c-030\"\u003e\u003cstrong\u003eWER40C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHeavier-duty circuits with higher inrush conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-63a-c-curve-type-a-30ma\"\u003e\u003cstrong\u003eWER63C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLarger commercial or high-load applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295845335416,"sku":"WER40B-030","price":19.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WER40B-030.png?v=1760363829"},{"product_id":"high-immunity-type-a-rcbo-16a-b-curve-30ma-wer16b-030","title":"High Immunity RCBO – 16A B Curve, Type A, 30mA (WER16B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWER16B-030\u003c\/strong\u003e is a \u003cstrong\u003e16A B Curve High Immunity Type A RCBO\u003c\/strong\u003e designed for solar PV, battery storage, and EV charger circuits. It provides combined \u003cstrong\u003eoverload, short-circuit, and 30mA residual current protection\u003c\/strong\u003e, with added resilience against nuisance tripping from harmonics or transient voltages.\u003c\/p\u003e\n\u003cp\u003eWith \u003cstrong\u003edouble pole disconnection\u003c\/strong\u003e and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e, this RCBO is a reliable choice for inverter-fed systems and domestic boards where compliance with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e is essential.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Use the \u003cstrong\u003eB Curve\u003c\/strong\u003e for standard circuits with low inrush current such as domestic lighting or socket outlets. For EV chargers, motors, or heat pumps, select the C Curve version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16A B Curve Type A RCBO\u003c\/strong\u003e – overload + earth leakage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity electronics\u003c\/strong\u003e – resists nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e – regulation compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – suitable for residential and commercial installs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble pole disconnection\u003c\/strong\u003e – isolates live + neutral\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – compatible with inverter-fed systems\u003c\/li\u003e\n\u003cli\u003eComplies with \u003cstrong\u003eBS EN 61009\u003c\/strong\u003e \u0026amp; \u003cstrong\u003e18th Edition Amendment 2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare High Immunity RCBOs\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06b\"\u003e\u003cstrong\u003eWER06B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eLighting and other low inrush final circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06c\"\u003e\u003cstrong\u003eWER06C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLow-rated circuits where higher inrush tolerance is preferred\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWER16B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eGeneral domestic final circuits with low inrush loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-c-curve-30ma-wer16c-030\"\u003e\u003cstrong\u003eWER16C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eSmall motors and circuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-b-curve-30ma-wer20b-030\"\u003e\u003cstrong\u003eWER20B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eDomestic final circuits requiring a higher current rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-c-curve-30ma-wer20c-030\"\u003e\u003cstrong\u003eWER20C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eCircuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-b-curve-30ma-wer32b-030\"\u003e\u003cstrong\u003eWER32B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eRing finals and other standard appliance circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-c-curve-30ma-wer32c-030\"\u003e\u003cstrong\u003eWER32C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHigher demand circuits and loads with greater inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-b-curve-30ma-wer40b-030\"\u003e\u003cstrong\u003eWER40B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eHigher load circuits with lower inrush characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-c-curve-30ma-wer40c-030\"\u003e\u003cstrong\u003eWER40C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHeavier-duty circuits with higher inrush conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-63a-c-curve-type-a-30ma\"\u003e\u003cstrong\u003eWER63C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLarger commercial or high-load applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55295859622264,"sku":"WER16B-030","price":19.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WER40B-030.png?v=1760363829"},{"product_id":"type-a-rcbo-10a-b-curve-30ma","title":"Type A RCBO – 10A B Curve, 30mA","description":"\u003cp\u003eThe \u003cstrong\u003eWRT110B-030\u003c\/strong\u003e is a \u003cstrong\u003e10A B Curve Type A RCBO\u003c\/strong\u003e combining \u003cstrong\u003eresidual current and overcurrent protection\u003c\/strong\u003e in one compact device. It features \u003cstrong\u003eswitched live and neutral disconnection\u003c\/strong\u003e for full isolation, a \u003cstrong\u003ehigh immunity design\u003c\/strong\u003e to reduce nuisance tripping, and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e for use in \u003cstrong\u003esolar PV, EV charging, and inverter-fed circuits\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDesigned to detect both AC and pulsating DC leakage currents, it ensures compliance with the \u003cstrong\u003e18th Edition Wiring Regulations (Amendment 2)\u003c\/strong\u003e. The slim 18mm module width allows direct installation into consumer units and distribution boards without wasted space.\u003c\/p\u003e\n\u003c!-- Installer Tip --\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e Select the \u003cstrong\u003eB Curve\u003c\/strong\u003e for lighting and general-purpose socket circuits with low inrush currents. For EV chargers, motors, or heat pumps, use the C Curve version instead.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10A B Curve Type A RCBO\u003c\/strong\u003e – 30mA residual + overload protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched live \u0026amp; neutral\u003c\/strong\u003e – full fault isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity\u003c\/strong\u003e – prevents nuisance trips from harmonics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional wiring\u003c\/strong\u003e – suitable for inverter-fed systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact single-module\u003c\/strong\u003e – fits 18mm DIN rail slots\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – resilient for domestic \u0026amp; light commercial installs\u003c\/li\u003e\n\u003cli\u003eTested to \u003cstrong\u003eIEC\/EN 61009-1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare WRT Range\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-6a-b-curve-30ma-wrt106b-030\"\u003e\u003cstrong\u003eWRT106B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eLighting \/ Small Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT110B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eGeneral Domestic Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-16a-c-curve-30ma-wrt116c-030\"\u003e\u003cstrong\u003eWRT116C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003eEV \/ Heat Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/type-a-rcbo-20a-b-curve-30ma-wrt120b-030\"\u003e\u003cstrong\u003eWRT120B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003eLight Commercial \/ Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55328102351224,"sku":"WRT110B-030","price":14.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT116B-030.png?v=1754319758"},{"product_id":"3-pole-type-a-rcbo-32a-b-curve-30ma-10ka-wrt332b-030","title":"3-Pole Type A RCBO – 32A B Curve 30mA 10kA (WRT332B-030)","description":"\u003cp\u003eThe WRT332B-030 is a \u003cstrong\u003e3-pole Type A RCBO\u003c\/strong\u003e providing combined residual current and overcurrent protection for \u003cstrong\u003ethree-phase circuits\u003c\/strong\u003e. Rated at \u003cstrong\u003e32A\u003c\/strong\u003e with a \u003cstrong\u003eB curve\u003c\/strong\u003e and \u003cstrong\u003e30mA sensitivity\u003c\/strong\u003e, it protects against overload, short-circuit, and earth leakage faults in a compact \u003cstrong\u003e3-module DIN rail format\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A residual current protection allows the device to detect \u003cstrong\u003eAC residual currents and pulsating DC components\u003c\/strong\u003e, making it suitable for modern electrical installations with electronic loads. The B curve tripping characteristic is ideal for circuits with \u003cstrong\u003elower inrush currents\u003c\/strong\u003e, such as lighting circuits, control systems, and general-purpose three-phase loads.\u003c\/p\u003e\n\u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1.5rem 0;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eInstaller note:\u003c\/strong\u003e The switched neutral design disconnects \u003cstrong\u003eL1, L2, L3, and N\u003c\/strong\u003e simultaneously, improving isolation safety and simplifying insulation resistance testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole Type A RCBO with integrated overcurrent protection\u003c\/li\u003e\n\u003cli\u003e32A rated current with B curve characteristic\u003c\/li\u003e\n\u003cli\u003e30mA residual current sensitivity\u003c\/li\u003e\n\u003cli\u003e10kA short-circuit breaking capacity\u003c\/li\u003e\n\u003cli\u003eSwitched neutral for full disconnection of live conductors\u003c\/li\u003e\n\u003cli\u003eCompact 3-module DIN rail design\u003c\/li\u003e\n\u003cli\u003eClear IN \/ OUT \/ LOAD terminal markings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable cellpadding=\"6\" border=\"1\" style=\"width: 100%; border-collapse: collapse; margin-top: 1.5rem;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #fff7f3;\"\u003e\n\u003cth\u003ePart Code\u003c\/th\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eCurve\u003c\/th\u003e\n\u003cth\u003eResidual Current\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT332B-030\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-20a-c-curve-30ma-10ka-wrt320c-030\"\u003eWRT320C-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-32a-c-curve-30ma-10ka-wrt332c-030\"\u003eWRT332C-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-40a-b-curve-30ma-10ka-wrt340b-030\"\u003eWRT340B-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-40a-c-curve-30ma-10ka-wrt340c-030\"\u003eWRT340C-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-50a-c-curve-30ma-10ka-wrt350c-030\"\u003eWRT350C-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe WRT332B-030 is a strong choice for three-phase circuits where \u003cstrong\u003eType A protection\u003c\/strong\u003e and a \u003cstrong\u003eB curve response\u003c\/strong\u003e are required to protect sensitive or low inrush loads.\u003c\/p\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55408931570040,"sku":"WRT332B-030","price":75.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT332C-030.png?v=1767710050"},{"product_id":"3-pole-type-a-rcbo-40a-b-curve-30ma-10ka-wrt340b-030","title":"3-Pole Type A RCBO – 40A B Curve 30mA 10kA (WRT340B-030)","description":"\u003cp\u003eThe WRT340B-030 is a \u003cstrong\u003e3-pole Type A RCBO\u003c\/strong\u003e designed for three-phase circuits requiring combined residual current and overcurrent protection at a \u003cstrong\u003e40A rated current\u003c\/strong\u003e. With a \u003cstrong\u003eB curve\u003c\/strong\u003e characteristic and \u003cstrong\u003e30mA sensitivity\u003c\/strong\u003e, it provides reliable protection against overload, short-circuit, and earth leakage faults in a compact \u003cstrong\u003e3-module DIN rail format\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eType A residual current protection allows detection of \u003cstrong\u003eAC residual currents and pulsating DC components\u003c\/strong\u003e, making this RCBO suitable for modern installations with electronic equipment. The B curve response is suited to circuits with \u003cstrong\u003elow inrush current characteristics\u003c\/strong\u003e, such as lighting, control systems, and sensitive three-phase loads.\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff7f3; padding: 1rem; border-left: 4px solid #ff6d02; margin: 1.5rem 0;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eInstaller note:\u003c\/strong\u003e The switched neutral design disconnects \u003cstrong\u003eL1, L2, L3, and N\u003c\/strong\u003e together, improving isolation safety and simplifying testing during commissioning and maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n  \u003cli\u003e3-pole Type A RCBO with integrated overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e40A rated current with B curve characteristic\u003c\/li\u003e\n  \u003cli\u003e30mA residual current sensitivity\u003c\/li\u003e\n  \u003cli\u003e10kA short-circuit breaking capacity\u003c\/li\u003e\n  \u003cli\u003eSwitched neutral for full disconnection of live conductors\u003c\/li\u003e\n  \u003cli\u003eCompact 3-module DIN rail design\u003c\/li\u003e\n  \u003cli\u003eClear IN \/ OUT \/ LOAD terminal markings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 1.5rem;\" border=\"1\" cellpadding=\"6\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #fff7f3;\"\u003e\n\u003cth\u003ePart Code\u003c\/th\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eCurve\u003c\/th\u003e\n\u003cth\u003eResidual Current\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWRT340B-030\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-20a-c-curve-30ma-10ka-wrt320c-030\"\u003eWRT320C-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-32a-b-curve-30ma-10ka-wrt332b-030\"\u003eWRT332B-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-32a-c-curve-30ma-10ka-wrt332c-030\"\u003eWRT332C-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-40a-c-curve-30ma-10ka-wrt340c-030\"\u003eWRT340C-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/3-pole-type-a-rcbo-50a-c-curve-30ma-10ka-wrt350c-030\"\u003eWRT350C-030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe WRT340B-030 is a solid option for three-phase circuits where \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e and a \u003cstrong\u003eB curve response\u003c\/strong\u003e are required for higher current, low inrush applications.\u003c\/p\u003e\n","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55408932979064,"sku":"WRT340B-030","price":75.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WRT332C-030.png?v=1767710050"},{"product_id":"high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06b","title":"High Immunity RCBO – 6A B Curve, Type A, 30mA (WER06B-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWER06B-030\u003c\/strong\u003e is a \u003cstrong\u003e6A B Curve High Immunity Type A RCBO\u003c\/strong\u003e designed for circuits requiring combined \u003cstrong\u003eoverload, short-circuit and residual current protection\u003c\/strong\u003e in a single device. It is especially suitable for \u003cstrong\u003elighting circuits\u003c\/strong\u003e and other low inrush final circuits where a 6A protective device is appropriate.\u003c\/p\u003e\n\u003cp\u003ePart of the Whitecliffe \u003cstrong\u003eWER High Immunity RCBO range\u003c\/strong\u003e, this model provides \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e for AC and pulsating DC leakage, along with \u003cstrong\u003edouble pole isolation\u003c\/strong\u003e and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e. Its high immunity design also helps reduce nuisance tripping in busy modern installations.\u003c\/p\u003e\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e A \u003cstrong\u003e6A B Curve RCBO\u003c\/strong\u003e is typically used on lighting and similar low inrush circuits. Where a circuit has a higher start-up characteristic, a \u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06c\"\u003e6A C Curve variant\u003c\/a\u003e may be the better fit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6A B Curve Type A RCBO\u003c\/strong\u003e – overload and residual current protection combined\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – helps resist nuisance tripping from transient disturbances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30mA sensitivity\u003c\/strong\u003e – suitable for additional protection applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – suitable for domestic and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble pole switching\u003c\/strong\u003e – disconnects live and neutral conductors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional supply\u003c\/strong\u003e – connection possible from top or bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN rail mounting\u003c\/strong\u003e – suits standard consumer units and boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A protection\u003c\/strong\u003e – detects AC and pulsating DC residual currents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompare High Immunity RCBOs\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWER06B-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eLighting and other low inrush final circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06c\"\u003e\u003cstrong\u003eWER06C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLow-rated circuits where higher inrush tolerance is preferred\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-b-curve-30ma-wer16b-030\"\u003e\u003cstrong\u003eWER16B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eGeneral domestic final circuits with low inrush loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-c-curve-30ma-wer16c-030\"\u003e\u003cstrong\u003eWER16C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eSmall motors and circuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-b-curve-30ma-wer20b-030\"\u003e\u003cstrong\u003eWER20B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eDomestic final circuits requiring a higher current rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-c-curve-30ma-wer20c-030\"\u003e\u003cstrong\u003eWER20C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eCircuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-b-curve-30ma-wer32b-030\"\u003e\u003cstrong\u003eWER32B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eRing finals and other standard appliance circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-c-curve-30ma-wer32c-030\"\u003e\u003cstrong\u003eWER32C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHigher demand circuits and loads with greater inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-b-curve-30ma-wer40b-030\"\u003e\u003cstrong\u003eWER40B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eHigher load circuits with lower inrush characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-c-curve-30ma-wer40c-030\"\u003e\u003cstrong\u003eWER40C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHeavier-duty circuits with higher inrush conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-63a-c-curve-type-a-30ma\"\u003e\u003cstrong\u003eWER63C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLarger commercial or high-load applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55510645932408,"sku":"WER06B-030","price":19.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WER40B-030.png?v=1760363829"},{"product_id":"high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06c","title":"High Immunity RCBO – 6A C Curve, Type A, 30mA (WER06C-030)","description":"\u003cp\u003eThe \u003cstrong\u003eWER06C-030\u003c\/strong\u003e is a \u003cstrong\u003e6A C Curve High Immunity Type A RCBO\u003c\/strong\u003e designed to provide combined \u003cstrong\u003eoverload, short-circuit and residual current protection\u003c\/strong\u003e in one compact device. It is a strong fit for circuits where a \u003cstrong\u003e6A protective rating\u003c\/strong\u003e is needed but where a \u003cstrong\u003eC Curve characteristic\u003c\/strong\u003e is preferred due to start-up current or circuit conditions.\u003c\/p\u003e\n\n\u003cp\u003eAs part of the Whitecliffe \u003cstrong\u003eWER High Immunity RCBO range\u003c\/strong\u003e, this model offers \u003cstrong\u003eType A protection\u003c\/strong\u003e for AC and pulsating DC residual currents, along with \u003cstrong\u003edouble pole isolation\u003c\/strong\u003e and \u003cstrong\u003ebi-directional wiring\u003c\/strong\u003e. That makes it well suited to modern consumer units and distribution boards where nuisance tripping resistance and installation flexibility are important.\u003c\/p\u003e\n\n\u003cdiv style=\"background: #f9f9f9; padding: 12px; border-left: 4px solid #ff6d02; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444;\"\u003e\u003cstrong\u003eInstaller Tip:\u003c\/strong\u003e A \u003cstrong\u003e6A C Curve RCBO\u003c\/strong\u003e can be useful where a low-rated circuit still has a higher inrush characteristic than a standard B Curve circuit. Always size the protective device to suit the actual design current and equipment characteristics.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6A C Curve Type A RCBO\u003c\/strong\u003e – combined overload and residual current protection in one device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh immunity design\u003c\/strong\u003e – helps reduce nuisance tripping in electrically noisy environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30mA sensitivity\u003c\/strong\u003e – suitable for additional protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e – suitable for a wide range of domestic and commercial boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble pole switching\u003c\/strong\u003e – disconnects live and neutral\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional supply\u003c\/strong\u003e – connection from top or bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN rail compatible\u003c\/strong\u003e – fits standard EN 60715 35mm rails\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A protection\u003c\/strong\u003e – detects AC and pulsating DC residual currents\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompare High Immunity RCBOs\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 1.5rem 0; font-size: 15px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #ff6d02; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid:#ddd;\"\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-6a-b-curve-type-a-30ma-wer06b\"\u003e\u003cstrong\u003eWER06B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eLighting and other low inrush final circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWER06C-030 (This Product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLow-rated circuits where higher inrush tolerance is preferred\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-b-curve-30ma-wer16b-030\"\u003e\u003cstrong\u003eWER16B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eGeneral domestic final circuits with low inrush loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-16a-c-curve-30ma-wer16c-030\"\u003e\u003cstrong\u003eWER16C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eSmall motors and circuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-b-curve-30ma-wer20b-030\"\u003e\u003cstrong\u003eWER20B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eDomestic final circuits requiring a higher current rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-20a-c-curve-30ma-wer20c-030\"\u003e\u003cstrong\u003eWER20C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eCircuits with moderately higher inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-b-curve-30ma-wer32b-030\"\u003e\u003cstrong\u003eWER32B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eRing finals and other standard appliance circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-32a-c-curve-30ma-wer32c-030\"\u003e\u003cstrong\u003eWER32C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHigher demand circuits and loads with greater inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-b-curve-30ma-wer40b-030\"\u003e\u003cstrong\u003eWER40B-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eHigher load circuits with lower inrush characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-type-a-rcbo-40a-c-curve-30ma-wer40c-030\"\u003e\u003cstrong\u003eWER40C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eHeavier-duty circuits with higher inrush conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/high-immunity-rcbo-63a-c-curve-type-a-30ma\"\u003e\u003cstrong\u003eWER63C-030\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eLarger commercial or high-load applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"power-and-data-uk","offers":[{"title":"Default Title","offer_id":55510646784376,"sku":"WER06C-030","price":19.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1387\/8168\/files\/WER40B-030.png?v=1760363829"}],"url":"https:\/\/poweranddatauk.co.uk\/collections\/b-curve-rcbos.oembed?page=4","provider":"power-and-data-uk","version":"1.0","type":"link"}